Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing

被引:2
作者
Biederer, Juergen
Gottwald, Tobias
Bolte, Hendrik
Riedel, Christian
Freitag, Sandra
Van Metter, Richard
Heller, Martin
机构
[1] Univ Hosp Schleswig Holstein, Dept Diagnost Radiol, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Inst Med Informat & Stat, Kiel, Germany
[3] Eastman Kodak Co, HI World Wide Res & Dev Rochester Med Phys, Washington, DC USA
关键词
pulmonary nodule; digital radiography; phantom; image latitude;
D O I
10.1007/s00330-006-0367-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate increased image latitude post-processing of digital projection radiograms for the detection of pulmonary nodules. 20 porcine lungs were inflated inside a chest phantom, prepared with 280 solid nodules of 4-8 mm in diameter and examined with direct radiography (3.0x2.5 k detector, 125 kVp, 4 mAs). Nodule position and size were documented by CT controls and dissection. Four intact lungs served as negative controls. Image post-processing included standard tone scales and increased latitude with detail contrast enhancement (log-factors 1.0, 1.5 and 2.0). 1280 sub-images (512x512 pixel) were centred on nodules or controls, behind the diaphragm and over free parenchyma, randomized and presented to six readers. Confidence in the decision was recorded with a scale of 0-100%. Sensitivity and specificity for nodules behind the diaphragm were 0.87/0.97 at standard tone scale and 0.92/0.92 with increased latitude (log factor 2.0). The fraction of "not diagnostic" readings was reduced (from 208/1920 to 52/1920). As an indicator of increased detection confidence, the median of the ratings behind the diaphragm approached 100 and 0, respectively, and the inter-quartile width decreased (controls: p < 0.001, nodules: p=0.239) at higher image latitude. Above the diaphragm, accuracy and detection confidence remained unchanged. Here, the sensitivity for nodules was 0.94 with a specificity from 0.96 to 0.97 (all p > 0.05). Increased latitude post-processing has minimal effects on the overall accuracy, but improves the detection confidence for sub-centimeter nodules in the posterior recesses of the lung.
引用
收藏
页码:1089 / 1100
页数:12
相关论文
共 35 条
[21]  
LEMMERS HEASJ, 1990, P SOC PHOTO-OPT INS, V1231, P437, DOI 10.1117/12.18823
[22]   COMPARISON OF A NEW DUAL CHARACTERISTIC FILM-SCREEN SYSTEM (INSIGHT) WITH A STANDARD FILM-SCREEN SYSTEM FOR CHEST RADIOLOGY [J].
LOGAN, PM ;
TUNNEY, T ;
MCCOY, CT ;
MASTERSON, J .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (794) :162-165
[23]   IMPACT OF POSTPROCESSING ON THE DETECTION OF SIMULATED PULMONARY NODULES WITH DIGITAL RADIOGRAPHY [J].
OESTMANN, JW ;
RUBENS, JR ;
BOURGOUIN, PM ;
RHEA, JT ;
LLEWELLYN, HJ ;
GREENE, R .
INVESTIGATIVE RADIOLOGY, 1989, 24 (06) :467-471
[24]   Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions [J].
Oschatz, E ;
Prokop, M ;
Scharitzer, M ;
Weber, M ;
Balassy, C ;
Schaefer-Prokop, C .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1472-1476
[25]  
PIZER SM, 1980, INFORMATION PROCESSI, P561
[26]   Subtle lung nodules: Influence of local anatomic variations on detection [J].
Samei, E ;
Flynn, MJ ;
Peterson, E ;
Eyler, WR .
RADIOLOGY, 2003, 228 (01) :76-84
[27]   Detection of subtle lung nodules: Relative influence of quantum and anatomic noise on chest radiographs [J].
Samei, E ;
Flynn, MJ ;
Eyler, WR .
RADIOLOGY, 1999, 213 (03) :727-734
[28]   UNIFORM PERCEPTUAL QUANTIZATION - APPLICATIONS TO DIGITAL RADIOGRAPHY [J].
SEZAN, MI ;
YIP, KL ;
DALY, SJ .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1987, 17 (04) :622-634
[29]   Computed radiography and direct radiography -: Influence of acquisition dose on the detection of simulated lung lesions [J].
Uffmann, M ;
Prokop, M ;
Eisenhuber, E ;
Fuchsjäger, M ;
Weber, M ;
Schaefer-Prokop, C .
INVESTIGATIVE RADIOLOGY, 2005, 40 (05) :249-256
[30]   Enhanced latitude for digital projection radiography [J].
Van Metter, R ;
Foos, D .
MEDICAL IMAGING 1999: IMAGE DISPLAY, 1999, 3658 :468-483