An Investigation of the Temporal Dark-Image-Sticking Phenomenon in an AC Plasma Display Panel With an Auxiliary Electrode

被引:3
作者
Jang, Cheol [1 ]
Choi, Kyung Cheol [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
关键词
Activated MgO layer; auxiliary electrode; plasma display; reset discharge; temporal dark image sticking; TEMPERATURE-DEPENDENT CHARACTERISTICS; PDP;
D O I
10.1109/TPS.2009.2037963
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In this paper, the temporal dark-image-sticking phenomenon in an ac plasma display panel (PDP) with an auxiliary electrode is investigated. To investigate this phenomenon, temporal behaviors of a black background image were observed in accordance with the sustain-discharge time and the relaxation time. Since dark image sticking is related to the reset discharge, our measurements focused on the reset period. In the case of an ac PDP with three electrodes, iterant sustain discharges induced an increase in black luminance, thereby leaving a residual image. However, in the case of an ac PDP with an auxiliary electrode, there was no variation of luminance between the states before and after the iterant sustain discharges. As a result, no residual image remained, and no distortion of the image could be recognized with the human eye, even after iterant sustain discharges.
引用
收藏
页码:106 / 112
页数:7
相关论文
共 13 条
[1]   Wall voltage and priming effect due to auxiliary electrode in AC PDP with auxiliary electrode [J].
Cho, Kwan Hyun ;
Lee, Sung-Min ;
Choi, Kyung Cheol .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (05) :1567-1573
[2]   Driving characteristics of a high-efficacy ac PDP with an auxiliary electrode [J].
Choi, Kyung Cheol ;
Jang, Cheol ;
Yun, Jin Bhum .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2008, 55 (06) :1338-1344
[3]   A new AC plasma display panel with auxiliary electrode for high luminous efficacy [J].
Choi, Kyung Cheol ;
Shin, Nam Hoon ;
Song, Sang Cheol ;
Lee, Jae Hyun ;
Park, Sang Dae .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2007, 54 (02) :210-218
[4]   A study on the measurement technique of image retention in AC plasma display panels [J].
Do, Yun Seon ;
Kim, Sang Ho ;
Choi, Kyung Cheol .
JOURNAL OF DISPLAY TECHNOLOGY, 2008, 4 (02) :238-244
[5]  
Han JG, 2004, PROGRESS OF MACHINING TECHNOLOGY, P965
[6]   Experimental observation of temperature-dependent characteristics for temporal dark boundary image sticking in 42-in AC-PDP [J].
Han, JW ;
Tae, HS ;
Shin, BJ ;
Chien, SI ;
Lee, DH .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (02) :324-330
[7]   Improved discharge time lag of address pulse in an ACPDP with auxiliary electrodes [J].
Jang, Cheol ;
Choi, Kyung Cheol .
JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2008, 16 (12) :1259-1267
[8]   The effect of the auxiliary electrode on the microplasma generated in a plasma display with a coplanar gap [J].
Kim, Seung Hun ;
Mun, Jeong Hun ;
Choi, Kyung Cheol ;
Lee, Seong-Eui .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (03) :650-655
[9]  
Kosaka T, 2005, IDW/AD '05: PROCEEDINGS OF THE 12TH INTERNATIONAL DISPLAY WORKSHOPS IN CONJUNCTION WITH ASIA DISPLAY 2005, VOLS 1 AND 2, P1469
[10]  
Shin BJ, 2005, IEEE T PLASMA SCI, V33, P162, DOI 10.1109/TPS.2004.841208