Experimental and numerical analysis for potential heat reuse in liquid cooled data centres

被引:56
作者
Carbo, Andreu [1 ]
Oro, Eduard [1 ]
Salom, Jaume [1 ]
Canuto, Mauro [2 ,3 ]
Macias, Mario [2 ,3 ]
Guitart, Jordi [2 ,3 ]
机构
[1] IREC, Jardins Dones Negre 1, St Adria De Besos 08930, Barcelona, Spain
[2] Barcelona Supercomp Ctr, C Jordi Girona 29, Barcelona 08034, Spain
[3] Univ Politecn Cataluna, C Jordi Girona 29, ES-08034 Barcelona, Spain
关键词
Data centre; Liquid cooling; IT load; Experimentation; Numerical modelling; RECOVERY; TEMPERATURE;
D O I
10.1016/j.enconman.2016.01.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
The rapid increase of data centre industry has stimulated the interest of both researchers and professionals in order to reduce energy consumption and carbon footprint of these unique infrastructures. The implementation of energy efficiency strategies and the use of renewables play an important role to reduce the overall data centre energy demand. Information Technology (IT) equipment produce vast amount of heat which must be removed and therefore waste heat recovery is a likely energy efficiency strategy to be studied in detail. To evaluate the potential of heat reuse a unique liquid cooled data centre test bench was designed and built. An extensive thermal characterization under different scenarios was performed. The effective liquid cooling capacity is affected by the inlet water temperature. The lower the inlet water temperature the higher the liquid cooling capacity; however, the outlet water temperature will be also low. Therefore, the requirements of the heat reuse application play an important role in the optimization of the cooling configuration. The experimental data was then used to validate a dynamic energy model developed in TRNSYS. This model is able to predict the behaviour of liquid cooling data centres and can be used to study the potential compatibility between large data centres with different heat reuse applications. The model also incorporates normalized power consumption profiles for heterogeneous workloads that have been derived from realistic IT loads. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:135 / 145
页数:11
相关论文
共 20 条
[1]  
ASHRAE, 2012, ASHRAE TC 9 9
[2]  
Bean JH, 2009, 138 AM POW CO
[3]  
Breen TJ, 2010, CHIP COOLING TOWER 1, DOI [http://dx.doi.org/10.1109/ITHERM.20105501421, DOI 10.1109/ITHERM.20105501421]
[4]  
Delimitrou C, 2013, 2013 IEEE INT S WORK
[5]   Experimental and numerical study of water-cooled datacom equipment [J].
Douchet, Fabien ;
Nortershauser, David ;
Le Masson, Stepahne ;
Glouannec, Patrick .
APPLIED THERMAL ENGINEERING, 2015, 84 :350-359
[6]   Thermo-economic analysis of steady state waste heat recovery in data centers using absorption refrigeration [J].
Ebrahimi, Khosrow ;
Jones, Gerard F. ;
Fleischer, S. .
APPLIED ENERGY, 2015, 139 :384-397
[7]   A review of data center cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities [J].
Ebrahimi, Khosrow ;
Jones, Gerard F. ;
Fleischer, Amy S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 :622-638
[8]  
Fuentes E, 2015, EUR SEM 99 ADV THERM
[9]   Experimental and numerical dynamic investigation of an energy efficient liquid cooled chiller-less data center test facility [J].
Gao, Tianyi ;
David, Milnes ;
Geer, James ;
Schmidt, Roger ;
Sammakia, Bahgat .
ENERGY AND BUILDINGS, 2015, 91 :83-96
[10]   Optimum supply air temperature ranges of various air-side economizers in a modular data center [J].
Ham, Sang-Woo ;
Park, Jun-Seok ;
Jeong, Jae-Weon .
APPLIED THERMAL ENGINEERING, 2015, 77 :163-179