Grid-Connected and Standalone Control for Dual-Stator Brushless Doubly Fed Induction Generator

被引:11
作者
Zeng, Yu [1 ]
Cheng, Ming [1 ]
Wei, Xinchi [2 ]
Zhang, Gan [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
[2] Shanghai Elect Power Res Inst, Shanghai 200437, Peoples R China
基金
中国国家自然科学基金;
关键词
Rotors; Windings; Stator windings; Induction machines; Voltage control; Inductance; Brushless doubly fed machine; current control; generators; machine vector control; wind power generation; MACHINE; OPERATION; SYSTEMS;
D O I
10.1109/TIE.2020.3028824
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article proposes an improved vector control scheme based on the magnetizing current for the dual-stator brushless doubly fed induction generator during the standalone operation. The conventional scheme of the standalone control chooses the control winding current as the control object for the inner current loop, suffering from the large variation of the output voltage caused by the large output impedance. The improved scheme of this article selects the power winding magnetizing current as the control object, which can reduce the demagnetizing influence of the load current. Meanwhile, the design of the outer voltage loop can be simplified because of the direct relationship between the output voltage and the power winding magnetizing current. The main aim of this article is to design an improved standalone controller to enhance the transient performance of the system. A prototype of the dual-stator brushless doubly fed induction generator, which employs the proposed scheme, is measured for validation.
引用
收藏
页码:9196 / 9206
页数:11
相关论文
共 50 条
[41]   Finite-Set Model Predictive Power Control of Brushless Doubly Fed Twin Stator Induction Generator [J].
Wei, Xinchi ;
Cheng, Ming ;
Zhu, Jianguo ;
Yang, Haitao ;
Luo, Rensong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (03) :2300-2311
[42]   Fuzzy Logic for Stator Current Harmonic Control in Doubly Fed Induction Generator [J].
de Santana, Marcelo P. ;
Jose Roberto, B. de A. M. ;
Geyverson, T. de P. ;
Thales, E. P. de A. ;
William, C. de A. P. ;
Carlos, O. .
IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, :2109-2115
[43]   Transient analysis of grid connected Doubly-fed induction generator [J].
Bankar, D. S. ;
Wadgaonkar, A. J. ;
Hirve, S. S. ;
Talange, D. B. .
2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, :1278-1283
[44]   Detailed Model of the Grid-Connected Cascaded Doubly Fed Induction Machine [J].
Mehrjardi, Ramin Tafazzoli ;
Ershad, Nima Farrokhzad ;
Rahrovi, Babak ;
Ehsani, Mehrdad .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (03) :3414-3423
[45]   Model predictive stator current control of doubly fed induction generator during network unbalance [J].
Cheng, Chenwen ;
Cheng, Peng ;
Nian, Heng ;
Sun, Dan .
IET POWER ELECTRONICS, 2018, 11 (01) :120-128
[46]   Stator side active and reactive power control with improved rotor position and speed estimator of a grid connected DFIG (doubly-fed induction generator) [J].
Gayen, P. K. ;
Chatterjee, D. ;
Goswami, S. K. .
ENERGY, 2015, 89 :461-472
[47]   Design and Analysis of a Novel Grid-Connected to Rotor Type Doubly Fed Induction Machine [J].
You, Yong-Min ;
Lipo, Thomas A. ;
Kwon, Byung-Il .
IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) :919-922
[48]   Integrated Control of a Motor/Generator Set Composed of Doubly Fed Induction Machines [J].
Bodson, Marc ;
Hossain, Md Abid .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (02) :1858-1869
[49]   Robust Predictive Rotor Current Control of a Doubly Fed Induction Generator Under an Unbalanced and Distorted Grid [J].
Zhang, Yongchang ;
Jiang, Tao .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (01) :433-442
[50]   Feature Investigation of a New Dual-Stator Doubly Salient Brushless DC Generator With and Without Rotor-Yoke [J].
Zhang, Zhuoran ;
Zhou, Yu ;
Yan, Yangguang .
2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, :1026-1031