Zoomed echo-planar diffusion tensor imaging for MR tractography of the prostate gland neurovascular bundle without an endorectal coil: a feasibility study

被引:5
作者
Ream, Justin M. [1 ]
Glielmi, Christopher [2 ]
Lazar, Mariana [1 ]
Campbell, Naomi [1 ,3 ]
Pfeuffer, Josef [4 ]
Schneider, Rainer [4 ]
Rosenkrantz, Andrew B. [1 ]
机构
[1] NYU, Dept Radiol, Sch Med, Langone Med Ctr, 660 1st Ave, New York, NY 10016 USA
[2] Siemens Healthcare, New York, NY USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10021 USA
[4] Siemens AG Healthcare Sector, Imaging & Therapy Div, Erlangen, Germany
关键词
Prostate gland; Diffusion tensor imaging; Parallel transmission; MR tractography; FIELD-OF-VIEW; RADICAL RETROPUBIC PROSTATECTOMY; 3; T; WEIGHTED MRI; CANCER; QUALITY; TRANSMISSION; PRESERVATION; EXCITATION; FIBERS;
D O I
10.1007/s00261-015-0587-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to assess the feasibility of zoomed echo-planar imaging (EPI) diffusion tensor imaging (DTI) with 2-channel parallel transmission (pTx) for MR tractography of the periprostatic neurovascular bundle (NVB) without an endorectal coil, and to compare its performance to that of conventionally acquired DTI. Methods: 8 healthy males (28.9 +/- 4.6 years) underwent pelvic phased-array coil prostate MRI on a 3T system using both zoomed-EPI DTI (z-DTI) with 2-channel pTx and conventional single-shot spin-echo EPI DTI (c-DTI) acquisitions with 6 encoding directions and b-values of 0 and 1000 s/mm(2). Fractional anisotropy (FA) maps and tractography analysis incorporating 3D visualization of the NVB were performed from each acquisition. Fiber tract counts, estimated signal-to-noise ratio (eSNR), and image quality measures of the FA maps and NVB tractography were compared. Quantitative and image quality measures were compared using Wilcoxon signed rank tests. Results: 3 of 8 subjects had no tracts detected with c-DTI acquisition, while all 8 had tracts detected with z-DTI. z-DTI acquisition yielded significantly more fiber tracts (c-DTI: 77 +/- 116 tracts; z-DTI: 430 +/- 228 tracts; p = 0.019) and higher eSNR (c-DTI: 2.9 +/- 1.2; z-DTI: 13.17 +/- 9.9; p = 0.014). Relative to c-DTI acquisitions, z-DTI FA maps showed significantly reduced artifact (p = 0.008) and reduced anatomic distortion of the prostate (p = 0.010), while z-DTI tractography showed significantly better overall visual quality (p = 0.011), tract symmetry (p = 0.010), tract coherence (p = 0.011), and subjective similarity to the actual NVB (p = 0.011). Conclusion: Zoomed-EPI DTI acquisition for tractography of the prostate gland NVB improves quantitative and qualitative measures of image and tract fiber quality, allowing tractography of the NVB at 3T without using an endorectal coil.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 33 条
[1]   Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence [J].
Barakat, N. ;
Mohamed, F. B. ;
Hunter, L. N. ;
Shah, P. ;
Faro, S. H. ;
Samdani, A. F. ;
Finsterbusch, J. ;
Betz, R. ;
Gaughan, J. ;
Mulcahey, M. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1127-1133
[2]   Diffusion-Weighted Imaging of the Prostate Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions [J].
Barth, Borna K. ;
Cornelius, Alexander ;
Nanz, Daniel ;
Eberli, Daniel ;
Donati, Olivio F. .
INVESTIGATIVE RADIOLOGY, 2015, 50 (11) :785-791
[3]   Assessment of reduced field of view in diffusion tensor imaging of the lumbar nerve roots at 3 T [J].
Budzik, Jean-Francois ;
Verclytte, Sebastien ;
Lefebvre, Guillaume ;
Monnet, Aurelien ;
Forzy, Gerard ;
Cotten, Anne .
EUROPEAN RADIOLOGY, 2013, 23 (05) :1361-1366
[4]   Anatomical studies of the neurovascular bundle and cavernosal nerves [J].
Costello, AJ ;
Brooks, M ;
Cole, OJ .
BJU INTERNATIONAL, 2004, 94 (07) :1071-1076
[5]   Diffusion Tensor Magnetic Resonance Tractography of the Prostate: Feasibility for Mapping Periprostatic Fibers [J].
Finley, David S. ;
Ellingson, Benjamin M. ;
Natarajan, Shyam ;
Zaw, Taryar M. ;
Raman, Steve S. ;
Schulam, Peter ;
Reiter, Robert E. ;
Margolis, Daniel .
UROLOGY, 2012, 80 (01) :219-223
[6]   Noise measurement and estimation in MR imaging experiments [J].
Heverhagen, Johannes T. .
RADIOLOGY, 2007, 245 (03) :638-639
[7]   The role of preoperative endorectal magnetic resonance imaging in the decision regarding whether to preserve or resect neurovascular bundles during radical retropubic prostatectomy [J].
Hricak, H ;
Wang, L ;
Wei, DC ;
Coakley, FV ;
Akin, O ;
Reuter, VE ;
Gonen, M ;
Kattan, MW ;
Onyebuchi, CN ;
Scardino, PT .
CANCER, 2004, 100 (12) :2655-2663
[8]   High-Resolution Diffusion Tensor Imaging of the Human Pons With a Reduced Field-of-View, Multishot, Variable-Density, Spiral Acquisition at 3 T [J].
Karampinos, Dimitrios C. ;
Van, Anh T. ;
Olivero, William C. ;
Georgiadis, John G. ;
Sutton, Bradley P. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) :1007-1016
[9]   Parallel RF transmission in MRI [J].
Katscher, U ;
Börnert, P .
NMR IN BIOMEDICINE, 2006, 19 (03) :393-400
[10]   Diffusion tensor imaging of normal prostate at 3 T: effect of number of diffusion-encoding directions on quantitation and image quality [J].
Kim, C. K. ;
Jang, S. M. ;
Park, B. K. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015) :E279-E283