In Vitro Studies of a Novel Antimicrobial Luer-Activated Needleless Connector for Prevention of Catheter-Related Bloodstream Infection

被引:34
|
作者
Maki, Dennis G. [1 ,2 ]
机构
[1] Univ Wisconsin, Sch Med, Dept Med, Infect Dis Sect, Madison, WI USA
[2] Univ Wisconsin Hosp & Clin, Madison, WI 53792 USA
关键词
DEVICE; CARE; COLONIZATION; PATHOGENESIS; SEPSIS; SILVER; IMPLEMENTATION; CONTAMINATION; INJURIES; OUTBREAK;
D O I
10.1086/652764
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. We report in vitro studies of a commercially available novel antimicrobial Luer-activated connector with the inner surface coated with nanoparticle-silver to prevent contaminants from forming biofilm and causing catheter-related bloodstream infection. Methods. Sterile control nonmedicated connectors and antimicrobial connectors were filled with similar to 1 x 10(5) cfu/mL of Staphylococcus epidermidis, methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, Enterobacter cloacae, Pseudomonas aeruginosa, or Candida albicans; after 24 h of incubation, the numbers of remaining viable microorganisms were quantified and compared with the concentration in control connectors (similar to 1 x 10(7) cfu/mL). In trials simulating clinical use, septal membranes of connectors were inoculated with E. cloacae, were allowed to dry, and were then actuated and infused with lactated ringer's solution for 72 h, with sampling for microorganisms in downstream efferent fluid and for biofilm in the connector. Results. Microorganisms suspended in the intraluminal fluid path of antimicrobial connectors were rapidly killed. For 5 species, there was a 5.23-6.80 mean log 10 reduction (>99.999%), and with C. albicans, there was a 99.9% reduction. In clinical simulation trials, heavy contamination of downstream fluid was detected at all time points with control connectors, reaching similar to 1 x 10(5) cfu/mL at 72 h, and heavy biofilm was uniformly present; with the antimicrobial connectors, there was complete prevention of downstream fluid contamination and total absence of biofilm formation. Conclusions. These simulation experiments show that needleless connectors readily acquire an internal biofilm when microorganisms gain access to the internal fluid path and that biofilm formation allows an exponential buildup of internal contamination, with shedding back into the fluid path and downstream sufficient to cause bacteremia. Incorporation of nanoparticle silver into the lining surfaces of the novel connector kills microorganisms in the fluid pathway and prevents internal biofilm formation, even with high levels of introduced contamination and continuous fluid flow. This technology deserves to be evaluated in a prospective, randomized clinical trial to determine its capacity to prevent catheter-associated bloodstream infection.
引用
收藏
页码:1580 / 1587
页数:8
相关论文
共 9 条
  • [1] Needleless Closed System Does Not Reduce Central Venous Catheter-Related Bloodstream Infection: A Retrospective Study
    Ishizuka, Mitsuru
    Nagata, Hitoshi
    Takagi, Kazutoshi
    Kubota, Keiichi
    INTERNATIONAL SURGERY, 2013, 98 (01) : 88 - 93
  • [2] Chlorhexidine-Impregnated Dressing for Prevention of Catheter-Related Bloodstream Infection: A Meta-Analysis
    Safdar, Nasia
    O'Horo, John C.
    Ghufran, Aiman
    Bearden, Allison
    Didier, Maria Eugenia
    Chateau, Dan
    Maki, Dennis G.
    CRITICAL CARE MEDICINE, 2014, 42 (07) : 1703 - 1713
  • [3] Antibiotic-based catheter lock solutions for prevention of catheter-related bloodstream infection: a systematic review of randomised controlled trials
    Snaterse, M.
    Ruger, W.
    Reimer, W. J. M. Scholte Op
    Lucas, C.
    JOURNAL OF HOSPITAL INFECTION, 2010, 75 (01) : 1 - 11
  • [4] Prevention of catheter-related bloodstream infections: analysis of studies published between 2002 and 2005
    Gastmeier, P.
    Geffers, C.
    JOURNAL OF HOSPITAL INFECTION, 2006, 64 (04) : 326 - 335
  • [5] Impact of a prevention program for catheter-related bloodstream infection in the intensive care unit of a tertiary hospital
    Esteve, Francisco
    Pujol, Miquel
    Ariza, Javier
    Gudiol, Francisco
    Verdaguer, Ricard
    Cisnal, Maria
    Jose Argerich, Maria
    Manez, Rafael
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2009, 27 (10): : 561 - 565
  • [6] Preclinical evaluation of passive disinfection caps with a long-term catheter for the prevention of catheter-related bloodstream infection in pediatric cancer patients
    Simon, Arne
    Fahrendorf, Wolfgang
    Hitschmann, Guido
    GMS HYGIENE AND INFECTION CONTROL, 2021, 16
  • [7] Vancomycin-lock therapy for prevention of catheter-related bloodstream infection in very low body weight infants
    Liang, Hong
    Zhang, Lian
    Guo, Xiaoping
    Sun, Li
    BMC PEDIATRICS, 2021, 21 (01)
  • [8] Prevention of Subsequent Catheter-Related Bloodstream Infection Using Catheter Locks in High-Risk Patients Receiving Home Parenteral Nutrition
    Davidson, Jacob B.
    Varayil, Jithinraj Edakkanambeth
    Okano, Akiko
    Whitaker, Jennifer A.
    Bonnes, Sara L.
    Kelly, Darlene G.
    Mundi, Manpreet S.
    Hurt, Ryan T.
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2017, 41 (04) : 685 - 690
  • [9] Antimicrobial Treatment on a Catheter-Related Bloodstream Infection (CRBSI) Case Due to Transition of a Multi-Drug-Resistant Ralstonia mannitolilytica from Commensal to Pathogen during Hospitalization
    Liu, Junyan
    Peters, Brian M.
    Yang, Ling
    Yu, Hui
    Feng, Donghua
    Chen, Dingqiang
    Xu, Zhenbo
    ANTIBIOTICS-BASEL, 2022, 11 (10):