Whole blood can be used as an alternative to isolated peripheral blood mononuclear cells to measure in vitro specific T-cell responses in human samples

被引:4
作者
Moris, Philippe [1 ]
Bellanger, Aurelie [1 ]
Ofori-Anyinam, Opokua [2 ]
Jongert, Erik [1 ]
Rodriguez, Juan-Pablo Yarzabal [1 ]
Janssens, Michel [1 ]
机构
[1] GSK, Rue Inst 89, B-1330 Rixensart, Belgium
[2] GSK, Ave Fleming 20, B-1300 Wavre, Belgium
关键词
T-cell responses; Intracellular cytokine staining; Peripheral blood mononuclear cells; Flow cytometry; Whole blood sample; Cell-mediated immunity; IMMUNITY; ASSAY;
D O I
10.1016/j.jim.2020.112940
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Vaccinology is confronted with diseases for which the control of T-cell responses by the vaccine is essential. Among the assays that have been designed to assess T-cell responses, intracellular cytokine staining (ICS) combined with flow cytometry is well-suited in the frame of clinical trials. This assay can be used starting from isolated peripheral blood mononuclear cells (PBMC) or from whole blood (WB), but firm equivalence between the two sample preparation methods has yet to be established. Therefore, we compared both methods by analyzing the frequency of antigen-specific CD4(+) T cells expressing at least two of four immune markers in human samples taken from two independent clinical trials (NCT00397943 and NCT00805389) with a qualified ICS assay. In the first study, M72-specific CD4(+) T-cell responses were analyzed using WB-ICS and PBMC-ICS in 293 samples. Of these, 128 were double positive (value >= lower limit of quantification [LLOQ] with both methods), 130 were double negative and only 35 sample results were discordant, leading to an overall agreement of 88.05%. When analyzing the 128 double positive samples, it was found that the geometric mean of ratios (GMR) for paired observations was 0.98, which indicates a very good alignment between the two methods. The Deming regression fitted between the methods also showed a good correlation with an estimated slope being 1.1085. In the second study, HBsAg-specific CD4(+) T-cell responses were analyzed in 371 samples. Of these, 100 were double positive, 195 were double negative and 76 sample results were discordant, leading to an overall agreement of 79.51%. The GMR for paired observations was equal to 1.20, caused by a trend for overestimation in favor of the WB samples in the very high frequencies. The estimated slope of the Deming regression was 1.3057. In conclusion, we demonstrated that WB and PBMC methods of sample collection led to statistically concordant ICS results, indicating that WB-ICS is a suitable alternative to PBMC-ICS to analyze clinical trial samples.
引用
收藏
页数:7
相关论文
共 12 条
[1]   Protective immunity following vaccination [J].
Amanna, Ian J. ;
Messaoudi, Ilhem ;
Slifka, Mark K. .
HUMAN VACCINES, 2008, 4 (04) :316-319
[2]  
[Anonymous], VACCINE, V31, P2196, DOI [10.1016/j.vaccine.2012.05.035, DOI 10.1016/J.VACCINE.2012.05.035]
[3]  
[Anonymous], J IMMUNOL METHODS, V434, P24, DOI [10.1016/j.jim.2016.04.003, DOI 10.1016/J.JIM.2016.04.003]
[4]   Comparison of whole blood and PBMC assays for T-cell functional analysis [J].
Deenadayalan A. ;
Maddineni P. ;
Raja A. .
BMC Research Notes, 6 (1)
[5]   Novel application of a whole blood intracellular cytokine detection assay to quantitate specific T-cell frequency in field studies [J].
Hanekom, WA ;
Hughes, J ;
Mavinkurve, M ;
Mendillo, M ;
Watkins, M ;
Gamieldien, H ;
Gelderbloem, SJ ;
Sidibana, M ;
Mansoor, N ;
Davids, V ;
Murray, RA ;
Hawkridge, A ;
Haslett, PAJ ;
Ress, S ;
Hussey, GD ;
Kaplan, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 291 (1-2) :185-195
[6]  
Hartmann S.B, 2016, REVISITING IFN GAMMA
[7]   Qualification of a whole blood intracellular cytokine staining assay to measure mycobacteria-specific CD4 and CD8 T cell immunity by flow cytometry [J].
Kagina, Benjamin M. ;
Mansoor, Nazma ;
Kpamegan, Eloi P. ;
Penn-Nicholson, Adam ;
Nemes, Elisa ;
Smit, Erica ;
Gelderbloem, Sebastian ;
Soares, Andreia P. ;
Abel, Brian ;
Keyser, Alana ;
Sidibana, Mzwandile ;
Hughes, Jane E. ;
Kaplan, Gilla ;
Hussey, Gregory D. ;
Hanekom, Willem A. ;
Scriba, Thomas J. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 417 :22-33
[8]   Impact of adjuvants on CD4+ T cell and B cell responses to a protein antigen vaccine: Results from a phase II, randomized, multicenter trial [J].
Leroux-Roels, Geert ;
Marchant, Arnaud ;
Levy, Jack ;
Van Damme, Pierre ;
Schwarz, Tino F. ;
Horsmans, Yves ;
Jilg, Wolfgang ;
Kremsner, Peter G. ;
Haelterman, Edwige ;
Clement, Frederic ;
Gabor, Julian J. ;
Esen, Meral ;
Hens, Annick ;
Carletti, Isabelle ;
Fissette, Laurence ;
Da Silva, Fernanda Tavares ;
Burny, Wivine ;
Janssens, Michel ;
Moris, Philippe ;
Didierlaurent, Arnaud M. ;
Van der Most, Robbert ;
Garcon, Nathalie ;
Van Belle, Pascale ;
Van Mechelen, Marcelle .
CLINICAL IMMUNOLOGY, 2016, 169 :16-27
[9]  
Moris P., 2013, IMPROVED CD4 T
[10]   How advances in immunology provide insight into improving vaccine efficacy [J].
Slifka, Mark K. ;
Amanna, Ian .
VACCINE, 2014, 32 (25) :2948-2957