Effectiveness of MiniMed 640G with SmartGuard ® System for prevention of hypoglycemia in pediatric patients with type 1 diabetes mellitus

被引:0
作者
Villafuerte Quispe, Beatriz [1 ]
Martin Frias, Maria [1 ]
Belen Roldan Martin, M. [1 ]
Yelmo Valverde, Rosa [1 ]
Angeles Alvarez Gomez, M. [1 ]
Barrio Castellanos, Raquel [1 ]
机构
[1] Hosp Univ Ramon y Cajal, Serv Pediat, Unidad Diabet Pediat, Madrid, Spain
来源
ENDOCRINOLOGIA DIABETES Y NUTRICION | 2017年 / 64卷 / 04期
关键词
Type; 1; diabetes; Predictive low glucose suspension; Pediatric age; MiniMed; 640G-SmartGuard; NOCTURNAL HYPOGLYCEMIA; INSULIN; SUSPENSION; DURATION; REDUCTION; SAFETY; RISK;
D O I
10.1016/j.endien.2017.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction/aims: Treatment with the MiniMed 640G-SmartGuard (R) system (640G-SG, sensoraugmented insulin pump system with low predicted glucose suspension feature) has been shown to decrease risk of hypoglycemia without altering metabolic control in patients with T1DM. The study purpose was to assess the impact of 640G-SG on hipoglycemia frequency and on metabolic control in a pediatric population with T1DM. Patients/methods: A retrospective study on 21 children treated with 640G-SG. HbA1c, mean blood glucose (mg/dL), glucose variation coefficient, frequency of hypoglycemia (< 70 mg/dL) and hyperglycemia (> 180 mg/dL), daily capillary blood glucose measurements, ketosis/diabetic ketoacidosis, and severe hypoglycemic episodes were analyzed and compared before and during use of the system. Fasting blood glucose, frequency of sensor use and number and duration of system suspension events were also assessed in the last month of use of the system. Results: All patients used the system continuously (5.0 +/- 2.1 months), with a median sensor use of 92%. Significant decreases were seen in hypoglycemia frequency (10.4 +/- 5.2% to 7.6 +/- 3.3%, p = 0.044) and number of capillary blood glucose measurements (11.3 +/- 2.2 to 8.1 +/- 2.1, p < 0.001), and there was no increase in hyperglycemia frequency (p = 0.65). Mean system suspension time was 3.1 +/- 1.2 h/day (37.3% of overnight stops). Changes in HbA1c, mean blood glucose, and variation coefficient were not significant. No patient experienced diabetic ketoacidosis or severe hypoglycemia. Conclusions: The sensor-augmented pump with the predictive low glucose suspension management system, as implemented in the 640G-SG system, can help avoid risk of hypoglycemiawithout significantly affecting metabolic control or causing diabetic ketoacidosis, and decreasethe burden of additional capillary blood glucose measurements in our pediatric cohort. (C) 2017 SEEN. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [41] Influence of the informal primary caretaker on glycemic control among prepubertal pediatric patients with type 1 diabetes mellitus
    Zurita-Cruz, Jessie Nallely
    Nishimura-Meguro, Elisa
    Villasis-Keever, Miguel Angel
    Hernandez-Mendez, Maria Elena
    Garrido-Magana, Eulalia
    Rivera-Hernandez, Aleida De Jesus
    JORNAL DE PEDIATRIA, 2017, 93 (02) : 136 - 141
  • [42] Factors associated with oxidative stress status in pediatric patients with type 1 diabetes mellitus
    Kacarevic, Dragana
    Bogavac-Stanojevic, Natasa
    Spasojevic-Kalimanovska, Vesna
    Bojanin, Dragana
    Milenkovic, Tatjana
    Stefanovic, Aleksandra
    Mihajlovic, Marija
    Vujcic, Sanja
    Vukovic, Rade
    Zeljkovic, Aleksandra
    Todorovic, Sladjana
    Mitrovic, Katarina
    Vekic, Jelena
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2020, 33 (05) : 591 - 598
  • [43] Impact of COVID-19 lockdown on blood glucose levels in pediatric patients with type 1 diabetes mellitus
    Cho, Min Hyung
    Shim, Young Suk
    Lee, Hae Sang
    ANNALS OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2025, 30 (01) : 25 - 30
  • [44] Modeling of glycogen resynthesis according to insulin concentration: towards a system for prevention of late-onset exercise-induced hypoglycemia in Type 1 diabetes patients
    Ajcevic, Milos
    Accardo, Agostino
    Francescato, Maria Pia
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS (KSE 2021), 2021, 192 : 2903 - 2911
  • [45] Cost-effectiveness of insulin degludec compared with insulin glargine in a basal-bolus regimen in patients with type 1 diabetes mellitus in the UK
    Evans, M.
    Wolden, M.
    Gundgaard, J.
    Chubb, B.
    Christensen, T.
    JOURNAL OF MEDICAL ECONOMICS, 2015, 18 (01) : 56 - 68
  • [46] Evaluation of therapeutics management patterns and glycemic control of pediatric type 1 diabetes mellitus patients in Turkey: A nationwide cross-sectional study
    Hatun, Sukru
    Demirbilek, Huseyin
    Darcan, Sukran
    Yuksel, Aysegul
    Binay, Cigdem
    Simsek, Damla Goksen
    Kara, Cengiz
    Cetinkaya, Ergun
    Unuvar, Tolga
    Ucakturk, Ahmet
    Tutunculer, Filiz
    Cesur, Yasar
    Bundak, Ruveyde
    Saglam, Halil
    Simsek, Enver
    Bereket, Abdullah
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 119 : 32 - 40
  • [47] Injection of acidic or neutral insulin and pain: A single-center, prospective, controlled, noninterventional study in pediatric patients with type 1 diabetes mellitus
    Karges, Beate
    Muche, Rainer
    Riegger, Ines
    Moritz, Martin
    Heinze, Eberhard
    Debatin, Klaus-Michael
    Wabitsch, Martin
    Karges, Wolfram
    CLINICAL THERAPEUTICS, 2006, 28 (12) : 2094 - 2101
  • [48] Acute Hypoglycemia Decreases Myocardial Blood Flow Reserve in Patients With Type 1 Diabetes Mellitus and in Healthy Humans
    Rana, Omar
    Byrne, Christopher D.
    Kerr, David
    Coppini, David V.
    Zouwail, Soha
    Senior, Roxy
    Begley, Joe
    Walker, Jeremy J.
    Greaves, Kim
    CIRCULATION, 2011, 124 (14) : 1548 - U146
  • [49] The Predictive Low Glucose Management System in Prevention of Clinically Significant Hypoglycemia in Type 1 Diabetes. A Preliminary Study Identifying the Most Common Events Leading Up to Hypoglycemia During Insulin Pump Therapy
    Thomakos, Petros
    Mitrakou, Asimina
    Kepaptsoglou, Olga
    Taraoune, Ibrahim
    Barreto, Carol
    Zoupas, Christos Sp.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2021, 129 (05) : 385 - 389
  • [50] POPULATION-BASED STUDY OF HYPOGLYCEMIA IN PATIENTS WITH TYPE 1 DIABETES MELLITUS REQUIRING EMERGENCY MEDICAL SERVICES
    Parsaik, Ajay K.
    Carter, Rickey E.
    Myers, Lucas A.
    Geske, Jennifer R.
    Smith, Steven A.
    Levine, James A.
    Basu, Ananda
    Kudva, Yogish C.
    ENDOCRINE PRACTICE, 2012, 18 (06) : 834 - 841