Effectiveness of MiniMed 640G with SmartGuard ® System for prevention of hypoglycemia in pediatric patients with type 1 diabetes mellitus

被引:0
作者
Villafuerte Quispe, Beatriz [1 ]
Martin Frias, Maria [1 ]
Belen Roldan Martin, M. [1 ]
Yelmo Valverde, Rosa [1 ]
Angeles Alvarez Gomez, M. [1 ]
Barrio Castellanos, Raquel [1 ]
机构
[1] Hosp Univ Ramon y Cajal, Serv Pediat, Unidad Diabet Pediat, Madrid, Spain
来源
ENDOCRINOLOGIA DIABETES Y NUTRICION | 2017年 / 64卷 / 04期
关键词
Type; 1; diabetes; Predictive low glucose suspension; Pediatric age; MiniMed; 640G-SmartGuard; NOCTURNAL HYPOGLYCEMIA; INSULIN; SUSPENSION; DURATION; REDUCTION; SAFETY; RISK;
D O I
10.1016/j.endien.2017.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction/aims: Treatment with the MiniMed 640G-SmartGuard (R) system (640G-SG, sensoraugmented insulin pump system with low predicted glucose suspension feature) has been shown to decrease risk of hypoglycemia without altering metabolic control in patients with T1DM. The study purpose was to assess the impact of 640G-SG on hipoglycemia frequency and on metabolic control in a pediatric population with T1DM. Patients/methods: A retrospective study on 21 children treated with 640G-SG. HbA1c, mean blood glucose (mg/dL), glucose variation coefficient, frequency of hypoglycemia (< 70 mg/dL) and hyperglycemia (> 180 mg/dL), daily capillary blood glucose measurements, ketosis/diabetic ketoacidosis, and severe hypoglycemic episodes were analyzed and compared before and during use of the system. Fasting blood glucose, frequency of sensor use and number and duration of system suspension events were also assessed in the last month of use of the system. Results: All patients used the system continuously (5.0 +/- 2.1 months), with a median sensor use of 92%. Significant decreases were seen in hypoglycemia frequency (10.4 +/- 5.2% to 7.6 +/- 3.3%, p = 0.044) and number of capillary blood glucose measurements (11.3 +/- 2.2 to 8.1 +/- 2.1, p < 0.001), and there was no increase in hyperglycemia frequency (p = 0.65). Mean system suspension time was 3.1 +/- 1.2 h/day (37.3% of overnight stops). Changes in HbA1c, mean blood glucose, and variation coefficient were not significant. No patient experienced diabetic ketoacidosis or severe hypoglycemia. Conclusions: The sensor-augmented pump with the predictive low glucose suspension management system, as implemented in the 640G-SG system, can help avoid risk of hypoglycemiawithout significantly affecting metabolic control or causing diabetic ketoacidosis, and decreasethe burden of additional capillary blood glucose measurements in our pediatric cohort. (C) 2017 SEEN. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [31] Pediatric Parenting Stress and Its Relation to Depressive Symptoms and Fear of Hypoglycemia in Parents of Young Children with Type 1 Diabetes Mellitus
    Patton, Susana R.
    Dolan, Lawrence M.
    Smith, Laura B.
    Thomas, Inas H.
    Powers, Scott W.
    JOURNAL OF CLINICAL PSYCHOLOGY IN MEDICAL SETTINGS, 2011, 18 (04) : 345 - 352
  • [32] Fear of hypoglycemia changes nutritional factors and behavioral strategies before the exercise in patients with type 1 diabetes mellitus
    Kaya, Nese
    Toklu, Hilal
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2023, 43 (04) : 559 - 565
  • [33] Sodium-Glucose Transporter Inhibition in Adult and Pediatric Patients with Type 1 Diabetes Mellitus
    Vitale, Rebecca J.
    Laffel, Lori M.
    ADVANCES IN CHRONIC KIDNEY DISEASE, 2021, 28 (04) : 309 - 317
  • [34] Osteopontin as a marker of vasculopathy in pediatric patients with type 1 diabetes mellitus: Relation to vascular structure
    Abo El-Asrar, Mohamed
    Ismail, Eman Abdel Rahman
    Thabet, Rasha Adel
    Kamel, Ashraf Sayed
    NehmedAllah, Sameh
    PEDIATRIC DIABETES, 2018, 19 (06) : 1107 - 1115
  • [35] A sensor augmented pump may improve awareness of hypoglycemia and quality of life in Japanese patients with type 1 diabetes mellitus
    Takagi, Satoshi
    Miura, Junnosuke
    Shimura, Kanako
    Hoshina, Sari
    Tsuchida, Yukiko
    Takita, Mikako
    Mochizuki, Shota
    Shen, Zhuo
    Asanuma, Takuya
    Takaike, Hiroko
    Babazono, Tetsuya
    DIABETOLOGY INTERNATIONAL, 2022, 13 (01) : 280 - 287
  • [36] Discrepancy between sensitization to inhaled allergens and respiratory symptoms in pediatric patients with type 1 diabetes mellitus
    Tosca, Maria Angela
    Villa, Elisa
    Silvestri, Michela
    D'Annunzio, Giuseppe
    Pistorio, Angela
    Aicardi, Marco
    Minicucci, Laura
    Lorini, Renata
    Rossi, Giovanni A.
    PEDIATRIC ALLERGY AND IMMUNOLOGY, 2009, 20 (04) : 385 - 391
  • [37] HYPOGLYCEMIA INCREASES THE GASTRIC-EMPTYING RATE IN PATIENTS WITH TYPE-1 DIABETES-MELLITUS
    SCHVARCZ, E
    PALMER, M
    AMAN, J
    LINDKVIST, B
    BECKMAN, KW
    DIABETIC MEDICINE, 1993, 10 (07) : 660 - 663
  • [38] Effectiveness of flash glucose monitoring in patients with type 1 diabetes and recurrent hypoglycemia between early and late stages after flash glucose monitoring initiation
    Contreras, Macarena
    Mesa, Alex
    Pueyo, Irene
    Claro, Maria
    Milad, Camila
    Vinals, Clara
    Roca, Daria
    Granados, Montse
    Gimenez, Marga
    Conget, Ignacio
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2023, 37 (08)
  • [39] Correlates of fear of hypoglycemia among patients with type 1 and 2 diabetes mellitus in outpatient hospitals in Zambia
    Hapunda, Given
    Abubakar, Amina
    Pouwer, Frans
    van de Vijver, Fons
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2020, 40 (04) : 619 - 626
  • [40] MiniMed 780G system performance in older users with type 1 diabetes: Real-world evidence and the case for stricter glycaemic targets
    Smaniotto, Vittorino
    Heller, Simon
    O'Neal, David
    Jendle, Johan
    Cukierman-Yaffe, Tali
    Arrieta, Arcelia
    Thijs, Isabeau
    Castaneda, Javier
    van den Heuvel, Tim
    Cohen, Ohad
    DIABETES OBESITY & METABOLISM, 2025, 27 (04) : 2242 - 2250