Morphometric analysis of eyelid fissure in patients with eyelid retraction in acute stage of dysthyroid orbitopathy after treatment with botulinum toxin type A
被引:3
作者:
Costa, Patricia Grativol
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, BrazilUniv Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, Brazil
Costa, Patricia Grativol
[1
]
Saraiva, Fabio Petersen
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, BrazilUniv Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, Brazil
Saraiva, Fabio Petersen
[1
]
Pereira, Ivana Cardoso
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, BrazilUniv Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, Brazil
Pereira, Ivana Cardoso
[1
]
Matayoshi, Suzana
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, BrazilUniv Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, Brazil
Matayoshi, Suzana
[1
]
机构:
[1] Univ Sao Paulo, Dept Oftalmol & Otorrinolaringol, Hosp Clin, BR-09500900 Sao Paulo, Brazil
Purpose: To compare morphometric data of eyelid fissure using computerized image analysis before and after application of botulinum toxin type A in patients with eyelid retraction caused by dysthyroid orbitopathy in acute stage. Methods: This was a prospective study with 12 individuals that received transcutaneous 5 UI/0.1 ml injection of botulinum toxin in the upper eyelid. They were examined periodically for 6 months. Clinical eyelid examination was performed and recorded using a video camera connected to a microcomputer. Results: Vertical eyelid fissure, upper eyelid margin to reflex distance and the eyelid area showed reduction in the treated eye. A decrease in the levator function of the upper eyelid was observed, and also, a reduction in the difference between the lateral and medial areas. The lower eyelid margin reflex distance did not show any significant differences after the application. Measurements of the contralateral eye increased up to 2 weeks after the application. Conclusions: These results showed a reduction in eyelid retraction and improving the upper eyelid contour, without changes in the lower eyelid position.
引用
收藏
页码:480 / 485
页数:6
相关论文
共 21 条
[21]
Waller R R, 1982, Trans Am Ophthalmol Soc, V80, P855