Application of 4D-CT in Poorly Located Parathyroid Adenomas: Surgical Correlation

被引:0
作者
Almeida, Joao [1 ]
Antunes, Natalie [1 ]
do Rosario, Francisco [2 ]
Garrao, Antonio [2 ]
Cid, Maria Olimpia [3 ]
Allen, Miguel [3 ]
Mendonca, Evelina [4 ]
Leal, Cecilia [1 ]
Figueiredo, Luisa [1 ]
Marques, Hugo [5 ,6 ]
机构
[1] Hosp Santa Marta, Serv Radiol, Ctr Hosp Lisboa Cent, Lisbon, Portugal
[2] Hosp Luz, Serv Endocrinol, Lisbon, Portugal
[3] Hosp Luz, Serv Cirurgia Gearl, Lisbon, Portugal
[4] Hosp Luz, Serv Anat Patol, Lisbon, Portugal
[5] Hosp Luz, Serv Radiol, Lisbon, Portugal
[6] Hosp Santa Marta, Ctr Hosp Lisboa Cent, Lisbon, Portugal
关键词
Adenoma/diagnostic imaging; Four-Dimensional Computed Tomography; Parathyroid Glands/diagnostic imaging; Parathyroid Neoplasms/diagnostic imaging; Preoperative Care; PRIMARY HYPERPARATHYROIDISM; COMPUTED-TOMOGRAPHY; LOCALIZATION; ACCURACY; MDCT; CT;
D O I
10.1016/j.rpedm.14.1.AO180041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Presurgical localization of parathyroid adenomas is important, improving surgical outcome and reducing its morbility. In the last years, cervico-thoracic four-dimensional computed tomography (4D-CT) has emerged as a complementary imaging technique to the traditional methods (ultrasound and scintigraphy) for presurgical localization of parathyroid adenomas of unknown location. We reviewed our initial experience in the use of 4D-CT in adults with primary hyperparathyroidism and negative or inconclusive traditional imaging modalities. Methods: Inclusion criteria were consecutive adults with primary hyperparathyroidism with negative or inconclusive traditional imaging modalities, who underwent 4D-CT and later curative surgery, between May 2015 and December 2017. We compared the report and images from 4D-CT to the histopathologic report after surgery. Results: Of the eleven patients who underwent cervical surgery, in 91% the histology was parathyroid adenoma (n=10) and in 9% parathyroid hyperplasia (n=1), with lowering of intraoperative parathyroid hormone in 77% of patients (n=7) and normalization of parathyroid hormone after surgery in 91% (n=10). 4D-CT identified all the cases of hyperfunctioning parathyroid tissue (n=11). Ultrasound and scintigraphy identified, respectively, 36% (n=4) and 18% (n=2) of the lesions. Conclusion: 4D-CT is a promising modality for localization of parathyroid adenomas of unknown location, as showed by our initial results, and should be considered in cases where ultrasound or scintigraphy were negative or inconclusive.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
[31]   The diagnostic value of 4D MRI at 3T for the localization of parathyroid adenomas [J].
Ozturk, Mesut ;
Polat, Ahmet Veysel ;
Celenk, Cetin ;
Elmali, Muzaffer ;
Kir, Seher ;
Polat, Cafer .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 112 :207-213
[32]   The Utility of 4D-CT Imaging in Primary Hyperparathyroidism Management in a Low-Volume Center [J].
Murruste, Marko ;
Kivilo, Martin ;
Kase, Karri ;
Kirsimagi, Ulle ;
Tahepold, Annika ;
Tammiksaar, Kaia .
MEDICINA-LITHUANIA, 2023, 59 (08)
[33]   Clinical validation of a 4D-CT based method for lung ventilation measurement in phantoms and patients [J].
Nyeng, Tine B. ;
Kallehauge, Jesper F. ;
Hoyer, Morten ;
Petersen, Jorgen B. B. ;
Poulsen, Per R. ;
Muren, Ludvig P. .
ACTA ONCOLOGICA, 2011, 50 (06) :897-907
[34]   Parathyroid 4D CT: What the Surgeon Wants to Know [J].
Bunch, Paul M. ;
Randolph, Gregory W. ;
Brooks, Jennifer A. ;
George, Valerie ;
Cannon, Jennifer ;
Kelly, Hillary R. .
RADIOGRAPHICS, 2020, 40 (05) :1383-1394
[35]   4D-CT Hyper-Elastography Using a Biomechanical Model [J].
Miranda, Dayton ;
Jafari, Parya ;
Dempsey, Sergio ;
Samani, Abbas .
42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, :1791-1794
[36]   Parathyroid 4D CT in Primary Hyperparathyroidism: Exploration of Size Measurements for Identifying Multigland Disease and Guiding Biochemically Successful Parathyroidectomy [J].
Bunch, Paul M. ;
Goyal, Aakshit ;
Valenzuela, Cristian D. ;
Randle, Reese W. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (05) :888-897
[37]   Dynamic 4D MRI for Characterization of Parathyroid Adenomas: Multiparametric Analysis [J].
Nael, K. ;
Hur, J. ;
Bauer, A. ;
Khan, R. ;
Sepandari, A. ;
Inampudi, R. ;
Guerrero, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) :2147-2152
[38]   Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings [J].
Yang, Liping ;
Gao, Xing ;
Gao, Chao ;
Xu, Shichuan ;
Cao, Shaodong .
BMC MEDICAL IMAGING, 2023, 23 (01)
[39]   The use of 4D-CT in assessing wrist kinematics and pathology A NARRATIVE REVIEW [J].
White, J. ;
Couzens, G. ;
Jeffery, C. .
BONE & JOINT JOURNAL, 2019, 101B (11) :1325-1330
[40]   Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation [J].
Teixeira, Pedro Augusto Gondim ;
Formery, Anne-Sophie ;
Hossu, Gabriela ;
Winninger, Daniel ;
Batch, Toufik ;
Gervaise, Alban ;
Blum, Alain .
EUROPEAN RADIOLOGY, 2017, 27 (02) :437-446