Application of 4D-CT in Poorly Located Parathyroid Adenomas: Surgical Correlation

被引:0
作者
Almeida, Joao [1 ]
Antunes, Natalie [1 ]
do Rosario, Francisco [2 ]
Garrao, Antonio [2 ]
Cid, Maria Olimpia [3 ]
Allen, Miguel [3 ]
Mendonca, Evelina [4 ]
Leal, Cecilia [1 ]
Figueiredo, Luisa [1 ]
Marques, Hugo [5 ,6 ]
机构
[1] Hosp Santa Marta, Serv Radiol, Ctr Hosp Lisboa Cent, Lisbon, Portugal
[2] Hosp Luz, Serv Endocrinol, Lisbon, Portugal
[3] Hosp Luz, Serv Cirurgia Gearl, Lisbon, Portugal
[4] Hosp Luz, Serv Anat Patol, Lisbon, Portugal
[5] Hosp Luz, Serv Radiol, Lisbon, Portugal
[6] Hosp Santa Marta, Ctr Hosp Lisboa Cent, Lisbon, Portugal
关键词
Adenoma/diagnostic imaging; Four-Dimensional Computed Tomography; Parathyroid Glands/diagnostic imaging; Parathyroid Neoplasms/diagnostic imaging; Preoperative Care; PRIMARY HYPERPARATHYROIDISM; COMPUTED-TOMOGRAPHY; LOCALIZATION; ACCURACY; MDCT; CT;
D O I
10.1016/j.rpedm.14.1.AO180041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Presurgical localization of parathyroid adenomas is important, improving surgical outcome and reducing its morbility. In the last years, cervico-thoracic four-dimensional computed tomography (4D-CT) has emerged as a complementary imaging technique to the traditional methods (ultrasound and scintigraphy) for presurgical localization of parathyroid adenomas of unknown location. We reviewed our initial experience in the use of 4D-CT in adults with primary hyperparathyroidism and negative or inconclusive traditional imaging modalities. Methods: Inclusion criteria were consecutive adults with primary hyperparathyroidism with negative or inconclusive traditional imaging modalities, who underwent 4D-CT and later curative surgery, between May 2015 and December 2017. We compared the report and images from 4D-CT to the histopathologic report after surgery. Results: Of the eleven patients who underwent cervical surgery, in 91% the histology was parathyroid adenoma (n=10) and in 9% parathyroid hyperplasia (n=1), with lowering of intraoperative parathyroid hormone in 77% of patients (n=7) and normalization of parathyroid hormone after surgery in 91% (n=10). 4D-CT identified all the cases of hyperfunctioning parathyroid tissue (n=11). Ultrasound and scintigraphy identified, respectively, 36% (n=4) and 18% (n=2) of the lesions. Conclusion: 4D-CT is a promising modality for localization of parathyroid adenomas of unknown location, as showed by our initial results, and should be considered in cases where ultrasound or scintigraphy were negative or inconclusive.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
  • [1] Diagnostic Accuracy of 4D-CT for Parathyroid Adenomas and Hyperplasia
    Chazen, J. L.
    Gupta, A.
    Dunning, A.
    Phillips, C. D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (03) : 429 - 433
  • [2] Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT
    Lundstroem, Anke Katrin
    Trolle, Waldemar
    Soerensen, Christian Hjort
    Myschetzky, Peter Sand
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (05) : 1253 - 1259
  • [3] 4D-CT for Detection of Parathyroid Adenomas and Hyperplasia: State of the Art Imaging
    Malinzak M.D.
    Sosa J.A.
    Hoang J.
    Current Radiology Reports, 5 (2)
  • [4] Dual energy 4D-CT of parathyroid adenomas not clearly localized by sestamibi scintigraphy and ultrasonography - a retrospective study
    Woisetschlager, M.
    Gimm, O.
    Johansson, K.
    Wallin, G.
    Albert-Garcia, I
    Spangeus, A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [5] Dual-Energy CT Characteristics of Parathyroid Adenomas on 25-and 55-Second 4D-CT Acquisitions: Preliminary Experience
    Forghani, Reza
    Roskies, Michael
    Liu, Xiaoyang
    Tan, Xianming
    Mlynarek, Alex
    Payne, Richard J.
    Nair, Jaykumar R.
    Hier, Michael P.
    Levental, Mark
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) : 806 - 814
  • [6] Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT
    Anke Katrin Lundstroem
    Waldemar Trolle
    Christian Hjort Soerensen
    Peter Sand Myschetzky
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 1253 - 1259
  • [7] Surgeon Review of 4D CT for Identification of Parathyroid Adenomas
    Kurian, Keerthi E.
    Hamdi, Osama
    Roecker, Zoe A.
    Barker, Simone A.
    Strumpf, Andrew
    Garneau, Jonathan C.
    Shonka, David C.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2024, : 839 - 846
  • [8] Is Intraoperative Parathyroid Hormone Monitoring Warranted in Cases of 4D-CT/Ultrasound Localized Single Adenomas?
    Heineman, Thomas E.
    Kutler, David I.
    Cohen, Marc A.
    Kuhel, William I.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2015, 153 (02) : 183 - 188
  • [9] 4D-CT is Superior to Ultrasound and Sestamibi for Localizing Recurrent Parathyroid Disease
    Hamidi, Moska
    Sullivan, Michael
    Hunter, George
    Hamberg, Leena
    Cho, Nancy L.
    Gawande, Atul A.
    Doherty, Gerard M.
    Moore, Francis D., Jr.
    Nehs, Matthew A.
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 (05) : 1403 - 1409
  • [10] Wall motion at 4D-CT angiography and surgical correlation in unruptured intracranial aneurysms: a pilot study
    Ferrari, Fabio
    Cirillo, Luigi
    Calbucci, Fabio
    Bartiromo, Fiorina
    Ambrosetto, Paolo
    Fioravanti, Antonio
    Leonardi, Marco
    JOURNAL OF NEUROSURGICAL SCIENCES, 2019, 63 (05) : 501 - 508