Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid chromatography for optimized sub-hour separations of complex peptide samples

被引:37
|
作者
Sarrut, Morgan [1 ]
Rouviere, Florent [1 ]
Heinisch, Sabine [1 ]
机构
[1] Univ Lyon 1, Inst Sci Analyt, CNRS, UMR 5280,ENS Lyon, 5 Rue Doua, F-69100 Villeurbanne, France
关键词
Fast; 2D-LC; On-line LCxLC-MS; Peptide mapping; Mass spectrometry; Optimization; Pareto-optimal approach; PEAK-CAPACITY; KINETIC PERFORMANCE; GRADIENT ELUTION; RESOLVING POWER; SYSTEMS; SPEED; TEMPERATURE; COLUMN; TIME;
D O I
10.1016/j.chroma.2017.01.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study was devoted to the search for conditions leading to highly efficient sub-hour separations of complex peptide samples with the objective of coupling to mass spectrometry. In this context, conditions for one dimensional reversed phase liquid chromatography (1D-RPLC) were optimized on the basis of a kinetic approach while conditions for on-line comprehensive two-dimensional liquid chromatography using reversed phase in both dimensions (on-line RPLCxRPLC) were optimized on the basis of a Pareto-optimal approach. Maximizing the peak capacity while minimizing the dilution factor for different analysis times (down to 5 min) were the two objectives under consideration. For gradient times between 5 and 60 min, 15 cm was found to be the best column length in RPLC with sub-2 mu m particles under 800 bar as system pressure. In RPLCxRPLC, for less than one hour as first dimension gradient time, the sampling rate was found to be a key parameter in addition to conventional parameters including column dimension, particle size, flow-rate and gradient conditions in both dimensions. It was shown that the optimum sampling rate was as low as one fraction per peak for very short gradient times (i.e. below 10 min). The quality descriptors obtained under optimized RPLCxRPLC conditions were compared to those obtained under optimized RPLC conditions. Our experimental results for peptides, obtained with state of the art instrumentation, showed that RPLCxRPLC could outperform 1D-RPLC for gradient times longer than 5 min. In 60 min, the same peak intensity (same dilution) was observed with both techniques but with a 3-fold lower injected amount in RPLCxRPLC. A significant increase of the signal-to-noise ratio mainly due to a strong noise reduction was observed in RPLCxRPLC-MS compared to the one in 1D-RPLC-MS making RPLCxRPLC-MS a promising technique for peptide identification in complex matrices. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 195
页数:13
相关论文
共 27 条
  • [21] On-Line Combination of High Performance Liquid Chromatography with Comprehensive Two-Dimensional Gas Chromatography-Triple Quadrupole Mass Spectrometry: A Proof of Principle Study
    Zoccali, Mariosimone
    Tranchida, Peter Quinto
    Mondello, Luigi
    ANALYTICAL CHEMISTRY, 2015, 87 (03) : 1911 - 1918
  • [22] Comparison of different setups for one- and two-dimensional capillary high-performance liquid chromatography and pressurized capillary electrochromatography coupled on-line with mass spectrometry
    Stahl, M
    Jakob, A
    von Brocke, A
    Nicholson, G
    Bayer, R
    ELECTROPHORESIS, 2002, 23 (17) : 2949 - 2962
  • [23] Separation and identification of flavonoids from complex samples using off-line two-dimensional liquid chromatography tandem mass spectrometry
    Zeng, Jing
    Zhang, Xiuli
    Guo, Zhimou
    Feng, Jiatao
    Zeng, Jianguo
    Xue, Xingya
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1220 : 50 - 56
  • [24] Evaluation of two sub-2 μm stationary phases, core-shell and totally porous monodisperse, in the second dimension of on-line comprehensive two dimensional liquid chromatography, a case study: Separation of milk peptides after expiration date
    Sommella, Eduardo
    Pepe, Giacomo
    Ventre, Giovanni
    Pagano, Francesco
    Manfra, Michele
    Pierri, Giuseppe
    Ismail, Omar
    Ciogli, Alessia
    Campiglia, Pietro
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1375 : 54 - 61
  • [25] One- and two-dimensional gas chromatography-mass spectrometry and high performance liquid chromatography-diode-array detector fingerprints of complex substances: A comparison of classification performance of similar, complex Rhizoma Curcumae samples with the aid of chemometrics
    Ni, Yongnian
    Mei, Minghua
    Kokot, Serge
    ANALYTICA CHIMICA ACTA, 2012, 712 : 37 - 44
  • [26] Protein- versus peptide fractionation in the first dimension of two-dimensional high-performance liquid chromatography-matrix-assisted laser desorption/ionization tandem mass spectrometry for qualitative proteome analysis of tissue samples
    Melchior, Katja
    Tholey, Andreas
    Heisel, Sabrina
    Keller, Andreas
    Lenhof, Hans-Peter
    Meese, Eckart
    Huber, Christian G.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (40) : 6159 - 6168
  • [27] Off-line comprehensive two-dimensional high-performance liquid chromatography system with size exclusion column and reverse phase column for separation of complex traditional Chinese medicine Qingkailing injection
    Ma, Sai
    Chen, Lingxin
    Luo, Guoan
    Ren, Kangning
    Wu, Juanfang
    Wang, Yiming
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 207 - 213