Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid chromatography for optimized sub-hour separations of complex peptide samples

被引:37
|
作者
Sarrut, Morgan [1 ]
Rouviere, Florent [1 ]
Heinisch, Sabine [1 ]
机构
[1] Univ Lyon 1, Inst Sci Analyt, CNRS, UMR 5280,ENS Lyon, 5 Rue Doua, F-69100 Villeurbanne, France
关键词
Fast; 2D-LC; On-line LCxLC-MS; Peptide mapping; Mass spectrometry; Optimization; Pareto-optimal approach; PEAK-CAPACITY; KINETIC PERFORMANCE; GRADIENT ELUTION; RESOLVING POWER; SYSTEMS; SPEED; TEMPERATURE; COLUMN; TIME;
D O I
10.1016/j.chroma.2017.01.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study was devoted to the search for conditions leading to highly efficient sub-hour separations of complex peptide samples with the objective of coupling to mass spectrometry. In this context, conditions for one dimensional reversed phase liquid chromatography (1D-RPLC) were optimized on the basis of a kinetic approach while conditions for on-line comprehensive two-dimensional liquid chromatography using reversed phase in both dimensions (on-line RPLCxRPLC) were optimized on the basis of a Pareto-optimal approach. Maximizing the peak capacity while minimizing the dilution factor for different analysis times (down to 5 min) were the two objectives under consideration. For gradient times between 5 and 60 min, 15 cm was found to be the best column length in RPLC with sub-2 mu m particles under 800 bar as system pressure. In RPLCxRPLC, for less than one hour as first dimension gradient time, the sampling rate was found to be a key parameter in addition to conventional parameters including column dimension, particle size, flow-rate and gradient conditions in both dimensions. It was shown that the optimum sampling rate was as low as one fraction per peak for very short gradient times (i.e. below 10 min). The quality descriptors obtained under optimized RPLCxRPLC conditions were compared to those obtained under optimized RPLC conditions. Our experimental results for peptides, obtained with state of the art instrumentation, showed that RPLCxRPLC could outperform 1D-RPLC for gradient times longer than 5 min. In 60 min, the same peak intensity (same dilution) was observed with both techniques but with a 3-fold lower injected amount in RPLCxRPLC. A significant increase of the signal-to-noise ratio mainly due to a strong noise reduction was observed in RPLCxRPLC-MS compared to the one in 1D-RPLC-MS making RPLCxRPLC-MS a promising technique for peptide identification in complex matrices. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 195
页数:13
相关论文
共 27 条
  • [1] Optimization of conditions in on-line comprehensive two-dimensional reversed phase liquid chromatography. Experimental comparison with one-dimensional reversed phase liquid chromatography for the separation of peptides
    Sarrut, Morgan
    D'Attoma, Amelie
    Heinisch, Sabine
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1421 : 48 - 59
  • [2] Analysis of the temporal performance of one versus on-line comprehensive two-dimensional liquid chromatography
    Potts, Lawrence W.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 37 - 44
  • [3] Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography
    Blumberg, Leonid M.
    David, Frank
    Klee, Matthew S.
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) : 2 - 16
  • [4] The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography
    Potts, Lawrence W.
    Stoll, Dwight R.
    Li, Xiaoping
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (36) : 5700 - 5709
  • [5] Quantitative aspects in on-line comprehensive two-dimensional liquid chromatography for pharmaceutical applications
    Iguiniz, Marion
    Corbel, Estelle
    Roques, Nicolas
    Heinisch, Sabine
    TALANTA, 2019, 195 : 272 - 280
  • [6] Optimizing the peak capacity per unit time in one-dimensional and off-line two-dimensional liquid chromatography for the separation of complex peptide samples
    Eeltink, Sebastiaan
    Dolman, Sebastiaan
    Swart, Remco
    Ursem, Mario
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7368 - 7374
  • [7] An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography
    Huang, Yuan
    Gu, Haiwei
    Filgueira, Marcelo
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (20) : 2984 - 2994
  • [8] Fraction transfer process in on-line comprehensive two-dimensional liquid-phase separations
    Cesla, Petr
    Krenkova, Jana
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (01) : 109 - 123
  • [9] Characterization and comparison of smokeless powders by on-line two-dimensional liquid chromatography
    van den Hurk, Rick S.
    Abdulhussain, Noor
    van Beurden, Anouk S. A.
    Dekker, Mabel E.
    Hulsbergen, Annemieke
    Peters, Ron A. H.
    Pirok, Bob W. J.
    van Asten, Arian C.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1672
  • [10] Pulsed elution modulation for on-line comprehensive two-dimensional liquid chromatography coupling reversed phase liquid chromatography and hydrophilic interaction chromatography
    Chen, Yingzhuang
    Wu, Yajun
    Liu, Xiaoming
    Li, Bowen
    Hu, Deping
    Huang, Si
    Ma, Ming
    Chen, Bo
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1583 : 98 - 107