Optimizing Image Quality for Pediatric Torso Computed Tomography: The Use of Advanced Iterative Reconstruction and Wide-Detector Scanning Techniques

被引:7
作者
Buchmann, Robert F. [1 ]
Greenberg, S. Bruce [1 ]
机构
[1] Arkansas Childrens Hosp, Dept Radiol, Little Rock, AR 72202 USA
关键词
computed tomography; pediatric imaging; iterative reconstruction; radiation exposure; FILTERED BACK-PROJECTION; DOSE REDUCTION; ABDOMINAL CT; NOISE; 3D;
D O I
10.1097/RCT.0000000000000122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare radiation exposure and image quality in children undergoing torso helical acquisition computed tomography (CT) using filtered back projection (FBP) or adaptive iterative dose reduction (AIDR) 3D reconstruction algorithms. A secondary purpose is to compare radiation exposure and image quality in children undergoing torso CT acquired with helical or wide-detector techniques reconstructed with AIDR 3D. Methods: The study was approved by the institutional review board. Phase 1 included 200 helical torso CT studies: 100 using FBP and 100 using AIDR 3D. The size-specific dose estimate (SSDE) was calculated for each study. Region of interest (ROI) noise measurements were recorded in the thorax, abdomen, and pelvis for each study. Unpaired t tests compared SSDE and image noise for each group. Phase 2 included 100 wide-detector CT torso studies using AIDR 3D. Size-specific dose estimate and ROI noise measurements were calculated. Unpaired t tests compared helical and wide-detector SSDE and ROI. Additional t tests looked for age-and weight-specific differences in the helical and wide-detector groups. Results: Phase 1: AIDR 3D showed significant reduction in SSDE (P = 0.0001) and significant improvement in image quality. Phase 2: no significant difference in SSDE was observed. Children younger than 6 years had a significant reduction in SSDE with wide-detector technique (P = 0.0445) with no loss in image quality. Conclusions: Adaptive iterative dose reduction 3D produces significant reduction in radiation dose without degradation to image quality compared with FBP. Significant dose reduction without loss of image quality can also be obtained in younger, smaller children using wide-detector technique.
引用
收藏
页码:786 / 789
页数:4
相关论文
共 16 条
  • [1] Boone JM, 2011, 204 AAPM, DOI [10.37206/143, DOI 10.37206/143]
  • [2] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [3] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    [J]. RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [4] Noise Reduction to Decrease Radiation Dose and Improve Conspicuity of Hepatic Lesions at Contrast-Enhanced 80-kV Hepatic CT Using Projection Space Denoising
    Ehman, Eric C.
    Guimaraes, Luis S.
    Fidler, Jeff L.
    Takahashi, Naoki
    Ramirez-Giraldo, Juan Carlos
    Yu, Lifeng
    Manduca, Armando
    Huprich, James E.
    McCollough, Cynthia H.
    Holmes, David, III
    Harmsen, W. Scott
    Fletcher, Joel G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 405 - 411
  • [5] CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT
    Gervaise, Alban
    Osemont, Benoit
    Lecocq, Sophie
    Noel, Alain
    Micard, Emilien
    Felblinger, Jacques
    Blum, Alain
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (02) : 295 - 301
  • [6] Computed tomography angiography in children with cardiovascular disease: low dose techniques and image quality
    Greenberg, S. Bruce
    Bhutta, Sadaf
    Braswell, Leah
    Chan, Frandics
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01) : 163 - 170
  • [7] Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT
    Johnston, Jennifer H.
    Podberesky, Daniel J.
    Yoshizumi, Terry T.
    Angel, Erin
    Toncheva, Greta
    Larson, David B.
    Egelhoff, John C.
    Anderson-Evans, Colin
    Nguyen, Giao B.
    Barelli, Alessandra
    Alsip, Christopher
    Salisbury, Shelia R.
    Frush, Donald P.
    [J]. PEDIATRIC RADIOLOGY, 2013, 43 (09) : 1117 - 1127
  • [8] Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection
    Matsuki, Mitsuru
    Murakami, Takamichi
    Juri, Hiroshi
    Yoshikawa, Shushi
    Narumi, Yoshifumi
    [J]. ACTA RADIOLOGICA, 2013, 54 (08) : 869 - 875
  • [9] Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis
    Mieville, Frederic A.
    Berteloot, Laureline
    Grandjean, Albane
    Ayestaran, Paul
    Gudinchet, Francois
    Schmidt, Sabine
    Brunelle, Francis
    Bochud, Francois O.
    Verdun, Francis R.
    [J]. PEDIATRIC RADIOLOGY, 2013, 43 (05) : 558 - 567
  • [10] Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
    Pearce, Mark S.
    Salotti, Jane A.
    Little, Mark P.
    McHugh, Kieran
    Lee, Choonsik
    Kim, Kwang Pyo
    Howe, Nicola L.
    Ronckers, Cecile M.
    Rajaraman, Preetha
    Craft, Alan W.
    Parker, Louise
    de Gonzalez, Amy Berrington
    [J]. LANCET, 2012, 380 (9840) : 499 - 505