New intraocular lens for achromatizing the human eye

被引:44
作者
Lopez-Gil, Norberto
Montes-Mico, Robert
机构
[1] Univ Valencia, Optometry Res Grp, E-46100 Valencia, Spain
[2] Univ Murcia, CiVi UM, E-30001 Murcia, Spain
关键词
D O I
10.1016/j.jcrs.2007.03.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe the design of a new intraocular lens (IOL) capable of correcting spherical and chromatic aberrations when implanted in the human eye. SETTING: University of Murcia, Murcia, and University of Valencia, Valencia, Spain. METHODS: A hybrid singlet achromatic IOL was designed. The IOL has a combination of a refractive and a diffractive surface, with 1 of the surfaces being aspherical. Optical simulations were used to model the polychromatic modulation transfer function (MTF) in pseudophakic eyes to explain the differences in optical quality afforded by the achromatic IOL. Parameters such as focus shift, optical path difference, through-focus, and robustness to tilt and decentering of achromatic IOLs were obtained. RESULTS: The polychromatic MTF in an eye with a centered, not tilted achromatic IOL was near the diffraction-limited MTF. The focus shift change for the achromatic IOL through the visible spectrum was approximately 0.1 diopter. The polychromatic MTF in an eye with the achromatic IOL would be similar to that in an eye with a spherically centered IOL if the achromatic IOL were decentered 1.0 mm or tilted 4 degrees. The range of centration and tilt error for the achromatic IOL to obtain an optical benefit in the polychromatic MTF was larger than the typical postoperative IOL decentration and tilt errors. CONCLUSION: The hybrid singlet achromatic IOL design resolved the chromatic aberration problem, improving the overall optical quality in the human eye.
引用
收藏
页码:1296 / 1302
页数:7
相关论文
共 30 条
[1]   EFFECT OF CHROMATIC ABERRATION ON VISUAL ACUITTY [J].
CAMPBELL, FW ;
GUBISCH, RW .
JOURNAL OF PHYSIOLOGY-LONDON, 1967, 192 (02) :345-&
[2]  
Castejón-Mochón JF, 2002, VISION RES, V42, P1611, DOI 10.1016/S0042-6989(02)00085-8
[3]   OBJECTIVE MEASUREMENTS OF LONGITUDINAL CHROMATIC ABERRATION OF HUMAN EYE [J].
CHARMAN, WN ;
JENNINGS, JAM .
VISION RESEARCH, 1976, 16 (09) :999-1005
[4]   WAVE-FRONT ABERRATION OF THE EYE - A REVIEW [J].
CHARMAN, WN .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (08) :574-583
[5]   Diffractive-refractive hybrid doublet to achromatize the human eye [J].
Díaz, JA ;
Irlbauer, M ;
Martínez, JA .
JOURNAL OF MODERN OPTICS, 2004, 51 (14) :2223-2234
[6]  
Holladay JT, 2002, J REFRACT SURG, V18, P683
[7]   DOES THE CHROMATIC ABERRATION OF THE EYE VARY WITH AGE [J].
HOWARTH, PA ;
ZHANG, XX ;
BRADLEY, A ;
STILL, DL ;
THIBOS, LN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (12) :2087-2092
[8]   THE LONGITUDINAL CHROMATIC ABERRATION OF THE HUMAN-EYE, AND ITS CORRECTION [J].
HOWARTH, PA ;
BRADLEY, A .
VISION RESEARCH, 1986, 26 (02) :361-366
[9]   Decentration and tilt: Silicone multifocal versus acrylic soft intraocular lenses [J].
Jung, CK ;
Chung, SK ;
Baek, NH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04) :582-585
[10]  
LEWIS AL, 1982, AM J OPTOM PHYS OPT, V59, P909