Corneal endothelial cell analysis using two non-contact specular microscopes in healthy subjects

被引:17
作者
Garza-Leon, Manuel [1 ]
机构
[1] Fdn Destellos Luz IBP, Pino Suarez 640,Consultorio 426, Monterrey, NL, Mexico
关键词
Corneal endothelium; Cell density; Non-contact specular microscopy; Endothelium size; Endothelium morphology; CATARACT-SURGERY; PENETRATING KERATOPLASTY; CONFOCAL MICROSCOPY; DENSITY; PHACOEMULSIFICATION; ANCILLARY; IMAGES; DONOR; COEFFICIENT; RELIABILITY;
D O I
10.1007/s10792-015-0133-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare specular microscopy values obtained using the Perseus (CSO, Italy) and the Nidek CEM-530 (NIDEK Co., Ltd. Japan) specular microscopes. This prospective study used specular microscopy to examine sixty eyes from thirty healthy subjects (29.83 +/- A 9.41 years; range 18-79 years). This was done with both the Nidek CEM-530 and the Perseus on three occasions and results were evaluated by one independent observer. Measurement differences between instruments and agreement between devices were determined. The endothelial cell sample was larger with the Perseus than with the CEM-530 (235.92 +/- A 38.26 vs. 184.38 +/- A 43.88, respectively) with a statistically significant difference (P = 0.001). Mean endothelial cell density (ECD) with the Perseus and CEM-530 was 2692.75 +/- A 306.66 and 2556.47 +/- A 257.38 cells/mm(2) (P = 0.001), respectively; mean coefficient of variation (CV) was 33.43 +/- A 4.29 and 28.70 +/- A 3.82 (P = 0.001), respectively, and hexagonality 56.66 +/- A 6.19 % and 68.50 +/- A 3.64 (P = 0.001), respectively. The mean of the differences (Perseus minus CEM-530) for ECD was 136.27 +/- A 106.16 cells/mm(2) (95 % CI 108.85-163.70 cells/mm(2)); 4.73 +/- A 2.70 % (95 % CI 4.03-5.41) in CV; and -11.83 +/- A 5.05 for percentage of hexagonal cells. Both instruments showed significant differences in the measurement of all cell forms, predominantly higher values were found with the Perseus vs the CEM-530, except 4-sided cells. Endothelial cell density, coefficient of variation, and percentage of hexagonal cells between the Perseus and CEM-530 differ statistically. This shows that these instruments should not be used interchangeably.
引用
收藏
页码:453 / 461
页数:9
相关论文
共 38 条
  • [1] The Endothelial Sample Size Analysis in Corneal Specular Microscopy Clinical Examinations
    Abib, Fernando C.
    Holzchuh, Ricardo
    Schaefer, Artur
    Schaefer, Tania
    Godois, Ronialci
    [J]. CORNEA, 2012, 31 (05) : 546 - 550
  • [2] Changes in endothelial cell density following penetrating keratoplasty and deep anterior lamellar keratoplasty
    Acar, Banu Torun
    Vural, Ece Turan
    Acar, Suphi
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2011, 4 (06) : 644 - 647
  • [3] Adina Berghian, 2008, Oftalmologia, V52, P84
  • [4] Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy
    Al Farhan, Haya Matuoq
    Al Otaibi, Wafa'a Majed
    Al Razqan, Hanouf Mohammed
    Al Harqan, Alanoud Abdullah
    [J]. BMC OPHTHALMOLOGY, 2013, 13
  • [5] Corneal Endothelial Cell Density and Morphology in Healthy Turkish Eyes
    Arici, Ceyhun
    Arslan, Osman Sevki
    Dikkaya, Funda
    [J]. JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [6] Specular microscopy ancillary study methods for donor endothelial cell density determination of cornea donor study images
    Benetz, BA
    Gal, RL
    Ruedy, KJ
    Rice, C
    Beck, RW
    Kalajian, AD
    Lass, JH
    [J]. CURRENT EYE RESEARCH, 2006, 31 (04) : 319 - 327
  • [7] Endothelial Morphometric Measures to Predict Endothelial Graft Failure After Penetrating Keratoplasty
    Benetz, Beth Ann
    Lass, Jonathan H.
    Gal, Robin L.
    Sugar, Alan
    Menegay, Harry
    Dontchev, Mariya
    Kollman, Craig
    Beck, Roy W.
    Mannis, Mark J.
    Holland, Edward J.
    Gorovoy, Mark
    Hannush, Sadeer B.
    Bokosky, John E.
    Caudill, James W.
    [J]. JAMA OPHTHALMOLOGY, 2013, 131 (05) : 601 - 608
  • [8] Agreed Statistics Measurement Method Comparison
    Bland, J. Martin
    Altman, Douglas G.
    [J]. ANESTHESIOLOGY, 2012, 116 (01) : 182 - 185
  • [9] Morphological Comparison of Specular Microscopy Images May Be a More Robust Indicator for Endothelial Stability Than Cell Density Estimations
    Boehringer, Daniel
    Reinhard, Thomas
    [J]. CORNEA, 2013, 32 (03) : 376 - 377
  • [10] Corneal endothelial cell loss and corneal thickness in conventional compared with femtosecond laser-assisted cataract surgery: Three-month follow-up
    Conrad-Hengerer, Ina
    Al Juburi, Mayss
    Schultz, Tim
    Hengerer, Fritz H.
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09) : 1307 - 1313