Determination of Estriol 16-glucuronide in human urine with surface plasmon resonance and lateral flow immunoassays

被引:18
|
作者
Jiang, Xiuqian [1 ,2 ]
Waterland, Mark [1 ,2 ]
Blackwell, Len [2 ]
Partridge, Ashton [1 ,2 ]
机构
[1] MacDiamid Inst Adv Mat & Nanotechnol, Palmerston North, New Zealand
[2] Massey Univ, Inst Fundamental Sci, Palmerston North, New Zealand
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; DIRECT RADIOIMMUNOASSAY; MENSTRUAL-CYCLE; VALIDATION; PREGNANCY; ASSAY; ESTRIOL-16-GLUCURONIDE; GLUCURONIDE;
D O I
10.1039/c001532f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid quantitative immunoassay for estriol-16-glucuronide by Surface Plasmon Resonance (SPR) sensing has been developed and applied to urine samples from non-pregnant and pregnant subjects. The assay was based on a partially-purified polyclonal antibody (pAb) raised in sheep, which showed negligible cross-reactivity with estrone-3-glucuronide and estriol-17-glucuronide. Colloidal gold coated by the pAb was used as the signal generator in the SPR-based inhibition immunoassay. An estriol-16-glucuronide-ovalbumin conjugate with an oligoethylene glycol (OEG) as linker was used to immobilize the steroid on the biosensor chip surface. The SPR assay had a limit of detection of 0.016 ng/mL, and could be performed rapidly giving results in two minutes. The assay can be carried out directly on any urine samples without complicated sample pretreatment. A one-step lateral flow strip test was also developed using the same pAb nanogold conjugates and bovine serum albumin estriol-16-glucuronide conjugates as the capture agent spotted onto a nitrocellulose membrane as the test line. A sensitive and repeatable lateral flow assay was achieved with a limit of detection of 0.49 ng/mL in time-diluted urine using a low coating concentration of the polyclonal antibody. Despite the strip sensor displaying adequate sensitivity in a standard curve generated by exposure to estriol-16-glucuronide in a spiked urine blank, the application of the strip sensors to real urine samples was not so successful due to matrix effects.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 7 条
  • [1] Sensitive determination of estriol-16-glucuronide using surface plasmon resonance sensing
    Jiang, Xiuqian
    Waterland, Mark
    Blackwell, Len
    Wu, Yinqiu
    Jayasundera, Krishanthi P.
    Partridge, Ashton
    STEROIDS, 2009, 74 (10-11) : 819 - 824
  • [2] Determination of 3-nitrotyrosine in human urine samples by surface plasmon resonance immunoassay
    Jin, Jing
    Wang, Chunyan
    Tao, Yi
    Tan, Yingjun
    Yang, Dacan
    Gu, Yin
    Dengb, Huihua
    Bai, Yanqiang
    Lu, Hua
    Wan, Yumin
    Lu, Zuhong
    Li, Yinghui
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 164 - 169
  • [3] Rapid surface plasmon resonance immunoassays for the determination of mycotoxins in cereals and cereal-based food products
    Meneely, J. P.
    Elliott, C. T.
    WORLD MYCOTOXIN JOURNAL, 2014, 7 (04) : 491 - 505
  • [4] Development of a surface plasmon resonance immunosensor and ELISA for 3-nitrotyrosine in human urine
    He, Qiyi
    Chen, Yingshan
    Shen, Ding
    Cui, Xiping
    Zhang, Chunguo
    Yang, Huiyi
    Zhong, Wenying
    Eremin, Sergei A.
    Fang, Yanxiong
    Zhao, Suqing
    TALANTA, 2019, 195 : 655 - 661
  • [5] Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor
    Mauriz, E
    Calle, A
    Abad, A
    Montoya, A
    Hildebrandt, A
    Barceló, D
    Lechuga, LM
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (11) : 2129 - 2136
  • [6] Lactoferrin determination using flow or batch immunosensor surface plasmon resonance: Comparison with amperometric and screen-printed immunosensor methods
    Tomassetti, Mauro
    Martini, Elisabetta
    Campanella, Luigi
    Favero, Gabriele
    Sanzo, Gabriella
    Mazzei, Franco
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 215 - 225
  • [7] Comparison of three immunosensor methods (surface plasmon resonance, screen-printed and classical amperometric immunosensors) for immunoglobulin G determination in human serum and animal or powdered milks
    Tomassetti, Mauro
    Martini, Elisabetta
    Campanella, Luigi
    Favero, Gabriele
    Carlucci, Luciano
    Mazzei, Franco
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 73 : 90 - 98