Design Method of LCL Filter for Grid-Connected Inverter Based on Particle Swarm Optimization and Screening Method

被引:31
作者
Cai, Yuxi [1 ]
He, Yingjie [1 ]
Zhou, Hongwei [1 ]
Liu, Jinjun [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Dept Ind Automat, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Double Fourier series; LCL filter; multiobjective optimization; particle swarm optimization (PSO); phase disposition pulsewidth modulation (PD-PWM); screening method; three-level grid-connected inverter; weak grid;
D O I
10.1109/TPEL.2021.3064701
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The trial and error method is the conventional method for LCL parameter design. Its efficiency is low and it is difficult to obtain the optimal parameter. Furthermore, due to the lack of detailed analysis of the high-frequency harmonics in the inverter output voltage, the designed LCL filter cannot effectively filter them, resulting that the quality of the grid-connected current cannot fully meet IEEE 519 standard. Based on the above-mentioned problems, the high-frequency harmonics of inverter output voltage is analyzed in detail in this article, and the multiobjective optimization function, including five optimization objectives, is constructed. Combined with the particle swarm optimization, a screening method is proposed to realize the multiobjective optimization process. Under the proposed method, the LCL parameter, which happens to meet the requirement of IEEE 519 for the high-frequency harmonic distortion rate of the grid-connected current, can be obtained, and the greatest tradeoff of LCL filtering performance and filter cost is achieved. In addition, the proposed method considers the problem of weak grid and provides a complete engineering solution for LCL parameter design in different degrees of weak grid. Finally, the effectiveness and accuracy of the proposed design method are verified by contrast simulation and experiment.
引用
收藏
页码:10097 / 10113
页数:17
相关论文
共 31 条
  • [1] [Anonymous], 2003, PULSEWIDTH MODULATIO
  • [2] [Anonymous], 2014, IEEE STANDARD
  • [3] [Anonymous], 2005, IEEE Std 1220-2005 (Revision of IEEE Std 1220-1998), DOI 10.1109/IEEESTD.2013.6673990
  • [4] Design and Analysis of a Higher Order Power Filter for Grid-Connected Renewable Energy Systems
    Anzalchi, Arash
    Moghaddami, Masood
    Moghadasi, Amir
    Pour, Maneli Malek
    Sarwat, Arif I.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (05) : 4149 - 4161
  • [5] Integral-series Fourier analysis of chaotic PWM patterns for common mode voltage stresses
    Asefi, Mahdi
    Nazarzadeh, Jalal
    [J]. IET POWER ELECTRONICS, 2018, 11 (09) : 1591 - 1602
  • [6] Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications
    Beres, Remus Narcis
    Wang, Xiongfei
    Blaabjerg, Frede
    Liserre, Marco
    Bak, Claus Leth
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 2083 - 2098
  • [7] Cao HN, 2019, C IND ELECT APPL, P2467, DOI [10.1109/iciea.2019.8833889, 10.1109/ICIEA.2019.8833889]
  • [8] Genetic Learning Particle Swarm Optimization
    Gong, Yue-Jiao
    Li, Jing-Jing
    Zhou, Yicong
    Li, Yun
    Chung, Henry Shu-Hung
    Shi, Yu-Hui
    Zhang, Jun
    [J]. IEEE TRANSACTIONS ON CYBERNETICS, 2016, 46 (10) : 2277 - 2290
  • [9] Modeling and Stability Analysis of LCL-Type Grid-Connected Inverters: A Comprehensive Overview
    Han, Yang
    Yang, Mengling
    Li, Hong
    Yang, Ping
    Xu, Lin
    Alves Coelho, Ernane Antonio
    Guerrero, Josep M.
    [J]. IEEE ACCESS, 2019, 7 : 114975 - 115001
  • [10] Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation
    He, Yuying
    Wang, Xuehua
    Ruan, Xinbo
    Pan, Donghua
    Xu, Xingping
    Liu, Fuxin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (12) : 12423 - 12436