Instrument to Enhance Visualization of Descemet Membrane During Graft Preparation for DMEK Surgery

被引:2
作者
Menzel-Severing, Johannes [1 ]
Salla, Sabine [2 ]
Plum, Wolfgang Joachim [2 ]
Tourtas, Theofilos [1 ]
Fuchsluger, Thomas [1 ]
Schloetzer-Schrehardt, Ursula [1 ]
Kruse, Friedrich Eduard [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, Schwabachanlage 6, D-91054 Erlangen, Germany
[2] Rhein Westfal TH Aachen, Dept Ophthalmol, Aachen, Germany
关键词
cornea; Descemet membrane; DMEK; endothelial keratoplasty; corneal transplantation; ENDOTHELIAL KERATOPLASTY; TRANSPLANTATION; RISK;
D O I
10.1097/ICO.0000000000000805
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:Descemet membrane (DM) endothelial keratoplasty has improved outcomes of corneal transplantation in patients with corneal endothelial disease. However, the procedure has been criticized for jeopardizing donor tissue during graft preparation. Standardization of this procedure may provide a way toward minimizing tissue loss. For this purpose, we propose the use of a novel tool.Methods:Computerized numerical control milling was used to create a blunt instrument, which was used to remove endothelial cells within a defined area in the periphery of donor corneas. Trypan blue was used to stain denuded DM. Graft preparation was continued as per our standard protocol. Transmission electron microscopy was performed on the treated area, and endothelial cell counts were obtained.Results:Use of the modified procedure resulted in delineation of a peripheral band of denuded DM, which readily stained with trypan blue. This provided increased visibility of DM during subsequent steps. Transmission electron microscopy confirmed that no structural deficits of DM were induced. Mean endothelial cell loss (SD) at 24 hours after preparation was 63 (+/- 130) cells per square millimeter in the group prepared with the use of the new instrument (n = 7), versus 116 (+/- 107) cells per square millimeter in the group prepared without the new instrument (n = 7; P = 0.45).Conclusions:The device presented here enhances visualization of DM during creation of the peripheral margin for subsequent lifting of the margin and stripping of the graft. This may increase success rates and shorten preparation times and learning periods for DM preparation. DM ultrastructure and endothelial cells were not negatively affected.
引用
收藏
页码:904 / 907
页数:4
相关论文
共 50 条
  • [41] Favourable outcome after late reorientation of an upside-down Descemet Membrane Endothelial Keratoplasty (DMEK) graft: a case report
    Mariacher, Siegfried
    Mariacher, Martina
    Boden, Karl Thomas
    Szurman, Peter
    Januschowski, Kai
    BMC OPHTHALMOLOGY, 2019, 19 (1)
  • [42] Descemet membrane detachment during cataract surgery: etiology and management
    Benatti, C. Andres
    Tsao, Jeffrey Z.
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (01) : 35 - 41
  • [43] Experimental evaluation of the novel ENDOJECT TM injector for the implantation of Descemet's membrane into the anterior chamber during DMEK
    Rossler, Kathrin
    Bachmann, Bjoern O.
    Armitage, John
    Tourtas, Theofilos
    Schlotzer-Schrehardt, Ursula
    Dockhorn, Volker
    Hohl, Emil
    Kruse, Friedrich E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [44] Pre-Descemet's endothelial keratoplasty: a simple, Descemet's membrane scoring technique for successful graft preparation
    Pereira, Nicolas Cesario
    Forseto, Adriana dos Santos
    Pereira Maluf, Rafaela Cesario
    Dua, Harminder Singh
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 786 - 789
  • [45] Learning curve of two common Descemet membrane endothelial keratoplasty graft preparation techniques
    Sella, Ruti
    Einan-Lifshitz, Adi
    Sorkin, Nir
    Chan, Clara C.
    Afshari, Natalie A.
    Rootman, David S.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2019, 54 (04): : 467 - 472
  • [46] Outcome after Descemet Membrane Endothelial Keratoplasty (DMEK) during a one surgeon learning curve converting from DSAEK
    Holtmann, Christoph
    Spaniol, Kristina
    Neumann, Inga
    Savinova, Darya
    Lisa, Kulp
    Geerling, Gerd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Graft-repositioning technique using infusion and small bubbles during Descemet's membrane endothelial keratoplasty
    Shimizu, Toshiki
    Oyakawa, Itaru
    Tomida, Daisuke
    Yokogawa, Hideaki
    Kobayashi, Akira
    Yamagami, Satoru
    Hayashi, Takahiko
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [48] Intensified Early Postoperative Topical Steroids Do Not Influence Endothelial Cell Density After Descemet Membrane Endothelial Keratoplasty Combined With Cataract Surgery (Triple-DMEK)
    Hoerster, Robert
    Stanzel, Tisha P.
    Bachmann, Bjoern O.
    Siebelmann, Sebastian
    Cursiefen, Claus
    CORNEA, 2016, 35 (11) : 1396 - 1400
  • [49] How to Avoid an Upside-Down Orientation of the Graft during Descemet Membrane Endothelial Keratoplasty?
    Wasielica-Poslednik, Joanna
    Schuster, Alexander K.
    Rauch, Lilian
    Glaner, Jessica
    Musayeva, Aytan
    Riedl, Jana C.
    Pfeiffer, Norbert
    Gericke, Adrian
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [50] Chord Mu (μ) and Chord Alpha (α) Length Changes in Fuchs Endothelial Corneal Dystrophy before and after Descemet Membrane Endothelial Keratoplasty (DMEK) Surgery
    Rocha-de-Lossada, Carlos
    Sanchez-Gonzalez, Jose-Maria
    Borroni, Davide
    Llorens-Belles, Victor
    Rachwani-Anil, Rahul
    Torras-Sanvicens, Josep
    Romano, Vito
    Peraza-Nieves, Jorge
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (21)