Instrument to Enhance Visualization of Descemet Membrane During Graft Preparation for DMEK Surgery

被引:2
作者
Menzel-Severing, Johannes [1 ]
Salla, Sabine [2 ]
Plum, Wolfgang Joachim [2 ]
Tourtas, Theofilos [1 ]
Fuchsluger, Thomas [1 ]
Schloetzer-Schrehardt, Ursula [1 ]
Kruse, Friedrich Eduard [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, Schwabachanlage 6, D-91054 Erlangen, Germany
[2] Rhein Westfal TH Aachen, Dept Ophthalmol, Aachen, Germany
关键词
cornea; Descemet membrane; DMEK; endothelial keratoplasty; corneal transplantation; ENDOTHELIAL KERATOPLASTY; TRANSPLANTATION; RISK;
D O I
10.1097/ICO.0000000000000805
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:Descemet membrane (DM) endothelial keratoplasty has improved outcomes of corneal transplantation in patients with corneal endothelial disease. However, the procedure has been criticized for jeopardizing donor tissue during graft preparation. Standardization of this procedure may provide a way toward minimizing tissue loss. For this purpose, we propose the use of a novel tool.Methods:Computerized numerical control milling was used to create a blunt instrument, which was used to remove endothelial cells within a defined area in the periphery of donor corneas. Trypan blue was used to stain denuded DM. Graft preparation was continued as per our standard protocol. Transmission electron microscopy was performed on the treated area, and endothelial cell counts were obtained.Results:Use of the modified procedure resulted in delineation of a peripheral band of denuded DM, which readily stained with trypan blue. This provided increased visibility of DM during subsequent steps. Transmission electron microscopy confirmed that no structural deficits of DM were induced. Mean endothelial cell loss (SD) at 24 hours after preparation was 63 (+/- 130) cells per square millimeter in the group prepared with the use of the new instrument (n = 7), versus 116 (+/- 107) cells per square millimeter in the group prepared without the new instrument (n = 7; P = 0.45).Conclusions:The device presented here enhances visualization of DM during creation of the peripheral margin for subsequent lifting of the margin and stripping of the graft. This may increase success rates and shorten preparation times and learning periods for DM preparation. DM ultrastructure and endothelial cells were not negatively affected.
引用
收藏
页码:904 / 907
页数:4
相关论文
共 50 条
  • [1] Scanning electron microscopy assessment of the Descemet membrane interface during DMEK graft preparation
    Cabrerizo, Javier
    Forshaw, Thomas
    Rodriguez-Aierbe, Clara
    Garrido-Fierro, Jesus
    SCIENTIFIC REPORTS, 2018, 8
  • [2] Descemet's membrane endothelial keratoplasty (DMEK): Analysis of a variation in Descemet's endothelial graft preparation
    D'azy, C. Benoist
    D'azy, C. Benoist
    Gabison, E.
    Sapin, V.
    Bosc, C.
    Pereira, B.
    Chiambaretta, F.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (05): : 371 - 385
  • [3] Descemet Membrane Endothelial Keratoplasty (DMEK) Under Previous DMEK for Secondary Endothelial Graft Failure
    Alio del Barrio, Jorge L.
    Vega-Estrada, Alfredo
    Alio, Jorge L.
    CORNEA, 2018, 37 (06) : 793 - 795
  • [4] Minimizing Graft Preparation Failure in Descemet Membrane Endothelial Keratoplasty
    Livny, Eitan
    Groeneveld-van Beek, Esther A.
    Lie, Jessica T.
    Mangundap, Kristin M.
    Bruinsma, Marieke
    Birbal, Renuka S.
    van der Wees, Jacqueline
    Melles, Gerrit R. J.
    CORNEA, 2017, 36 (12) : 1452 - 1457
  • [5] Graft preparation for hemi-Descemet membrane endothelial keratoplasty (hemi-DMEK)
    Lie, Jessica T.
    Lam, Fook Chang
    Beek, Esther A. Groeneveld-van
    van der Wees, Jacqueline
    Melles, Gerrit R. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (03) : 420 - 424
  • [6] Graft dislocation and graft failure following Descemet membrane endothelial keratoplasty (DMEK) using precut tissue: a retrospective cohort study
    Sonja Heinzelmann
    Daniel Böhringer
    Philipp Eberwein
    Thomas Reinhard
    Philip Maier
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 127 - 133
  • [7] Graft dislocation and graft failure following Descemet membrane endothelial keratoplasty (DMEK) using precut tissue: a retrospective cohort study
    Heinzelmann, Sonja
    Boehringer, Daniel
    Eberwein, Philipp
    Reinhard, Thomas
    Maier, Philip
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (01) : 127 - 133
  • [8] Histological and Ultrastructural Analysis of the Descemet's Membrane after Descemetorhexis in DMEK Surgery
    Roeck, D.
    Bayyoud, T.
    Hofmann, J.
    Bartz-Schmidt, K-U.
    Yoeruek, E.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (06) : 624 - 627
  • [9] Influence of Donor Factors on Descemet Membrane Endothelial Keratoplasty (DMEK) Graft Preparation Outcome
    Schrittenlocher, Silvia
    Weliwitage, Jithmi
    Matthaei, Mario
    Bachmann, Bjoern
    Cursiefen, Claus
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 793 - 797
  • [10] Graft survival of Descemet membrane endothelial keratoplasty (DMEK) in corneal endothelial decompensation after glaucoma surgery
    Schrittenlocher, Silvia
    Grass, C.
    Dietlein, T.
    Lappas, A.
    Matthaei, M.
    Cursiefen, C.
    Bachmann, B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (05) : 1573 - 1582