MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

被引:20
作者
Garnon, J. [1 ]
Ramamurthy, N. [2 ]
Caudrelier, J. J. [1 ]
Erceg, G. [3 ]
Breton, E. [3 ]
Tsoumakidou, G. [1 ]
Rao, P. [1 ,3 ]
Gangi, A. [1 ,3 ]
机构
[1] Nouvel Hop Civil, Dept Intervent Radiol, Strasbourg, France
[2] Norfolk & Norwich Univ Hosp, Dept Radiol, Colney Lane, Norwich NR4 7UY, Norfolk, England
[3] Univ Strasbourg, CNRS, ICube, Strasbourg, France
关键词
MRI guidance; Percutaneous imageguided biopsy; Mediastinal masses; NEEDLE-BIOPSY; PULMONARY NODULES; DIAGNOSTIC YIELD; CT; GUIDANCE; ASPIRATION; ACCURACY; SYSTEM; SAFETY; RISK;
D O I
10.1007/s00270-015-1246-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner. This is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed. Target lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6-11 cm). Average time for needle placement was 9.4 min (range 3-18 min); average duration of entire procedure was 42 min (range 27-62 min). 2-5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively. MRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 21 条
[1]  
Ahrar Judy U, 2011, Top Magn Reson Imaging, V22, P189, DOI 10.1097/RMR.0b013e31827c2e66
[2]   MEDIASTINAL MASSES - ALTERNATIVE APPROACHES TO CT-GUIDED NEEDLE-BIOPSY [J].
BRESSLER, EL ;
KIRKHAM, JA .
RADIOLOGY, 1994, 191 (02) :391-396
[3]   Diagnostic Yield and Safety of Computed Tomography-guided Mediastinal Core Needle Biopsies [J].
de Margerie-Mellon, Constance ;
de Bazelaire, Cedric ;
Amorim, Sandy ;
Brice, Pauline ;
Tazi, Abdellatif ;
Briere, Josette ;
Frija, Jacques ;
de Kerviler, Eric .
JOURNAL OF THORACIC IMAGING, 2015, 30 (05) :319-327
[4]   HEAD AND NECK LESIONS - MR-GUIDED ASPIRATION BIOPSY [J].
DUCKWILER, G ;
LUFKIN, RB ;
TERESI, L ;
SPICKLER, E ;
DION, J ;
VINUELA, F ;
BENTSON, J ;
HANAFEE, W .
RADIOLOGY, 1989, 170 (02) :519-522
[5]   Evaluation of percutaneous biopsies of renal masses under MRI-guidance: a retrospective study about 26 cases [J].
Garnon, J. ;
Schlier, A. ;
Buy, X. ;
Tsoumakidou, G. ;
de Mathelin, M. ;
Breton, E. ;
Gangi, A. .
EUROPEAN RADIOLOGY, 2015, 25 (03) :617-623
[6]   Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: Assessment of techniques and applicability [J].
Genant, JW ;
Vandevenne, JE ;
Bergman, AG ;
Beaulieu, CF ;
Kee, ST ;
Norbash, AM ;
Lang, P .
RADIOLOGY, 2002, 223 (01) :127-136
[7]   Estimated radiation exposure and cancer risk from CT and PET/CT scans in patients with lymphoma [J].
Guttikonda, Ravi ;
Herts, Brian R. ;
Dong, Frank ;
Baker, Mark E. ;
Fenner, Kathleen B. ;
Pohlman, Brad .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) :1011-1015
[8]   Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time [J].
Hoffmann, Rudiger ;
Thomas, Christoph ;
Rempp, Hansjorg ;
Schmidt, Diethard ;
Pereira, Philippe L. ;
Claussen, Claus D. ;
Clasen, Stephan .
EUROPEAN RADIOLOGY, 2012, 22 (03) :663-671
[9]   MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system [J].
Kariniemi, J ;
Sequeiros, RB ;
Ojala, R ;
Tervonen, O .
EUROPEAN RADIOLOGY, 2005, 15 (06) :1256-1262
[10]   MRI-guided percutaneous coaxial cutting needle biopsy of small pulmonary nodules: feasibility [J].
Liu, Ming ;
Lv, Yubo ;
Wu, Lebin ;
Song, Jiqing ;
Sequeiros, Roberto Blanco ;
Li, Chengli .
EUROPEAN RADIOLOGY, 2013, 23 (10) :2730-2738