Characterization of Electrical Reconnection Following Pulmonary Vein Isolation Using First- and Second-Generation Cryoballoon

被引:18
作者
Koektuerk, Buelent [1 ]
Yorgun, Hikmet [1 ]
Koektuerk, Oezlem [1 ]
Turan, Cem H. [1 ,2 ]
Keskin, Kerim [1 ]
Schoett, Moritz [1 ]
Turan, Ramazan G. [1 ]
Gorr, Eduard [1 ]
Hoppe, Christian [1 ]
Horlitz, Marc [1 ]
机构
[1] Univ Witten Herdecke, Dept Cardiol Electrophysiol, Krankenhaus Porz Rhein, Cologne, Germany
[2] Univ Hosp Rostock, Dept Internal Med, Div Cardiol, Rostock, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2016年 / 39卷 / 05期
关键词
pulmonary vein reconnection; cryoballoon ablation; pulmonary vein isolation; atrial fibrillation; ABLATION; CATHETER; EFFICACY; OUTCOMES;
D O I
10.1111/pace.12834
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Second-generation cryoballoon (CB-2) is associated with improved outcomes for pulmonary vein isolation (PVI) compared to first generation (CB-1). However, data regarding the predictors of pulmonary vein (PV) electrical reconnection are limited. In this study, we aimed to characterize the predilection sites and predictors of reconnection in patients with recurrent atrial tachyarrhythmia (ATa) after PVI using CB-1 and CB-2. Methods: A total of 59 patients (mean age: 62 11 years and 66% male) with recurrent ATa after previous CB-PVI, using either a 28-mm CB-1 or CB-2, underwent repeat ablation. PV reisolation was performed by irrigated radiofrequency ablation using three-dimensional electroanatomical mapping systems. Results: Electrical PV reconnection was detected in 10 of 11 (91%) of CB-1 patients compared to 41 of 48 (85%) of CB-2 patients. Time to redo procedure after index CB-1 was 8.9 +/- 10.2 months and 11.2 +/- 7.0 months in CB-2. Bonus freeze was applied in all patients with CB-1 and 41% of the patients with CB-2. Superior quadrants of both superior PVs and inferior quadrants of the both inferior PVs exhibited higher predilection for conduction compared to other quadrants (P < 0.001). Multivariate binary logistic analysis revealed that right inferior PV (RIPV; odds ratio [OR]: 1.52, 95% confidence interval [CI]: 1.09-2.13, P = 0.014) and minimum temperature (OR: 1.09, 95% CI: 1.03-1.15, P = 0.004) were the independent predictors of electrical reconnection after CB-2 ablation. Conclusion: Conduction gaps after CB-1 and CB-2 were higher in inferior PVs compared to superior PVs. The RIPV and minimum CB temperature were independent predictors of PV electrical reconnection after CB-2.
引用
收藏
页码:434 / 442
页数:9
相关论文
共 50 条
  • [41] Comparison between First- and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation
    Conti, Sergio
    Moltrasio, Massimo
    Fassini, Gaetano
    Tundo, Fabrizio
    Riva, Stefania
    Dello Russo, Antonio
    Casella, Michela
    Majocchi, Benedetta
    Marino, Vittoria
    De Iuliis, Pasquale
    Catto, Valentina
    Pala, Salvatore
    Tondo, Claudio
    [J]. CARDIOLOGY RESEARCH AND PRACTICE, 2016, 2016
  • [42] Luminal esophageal temperature predicts esophageal lesions after second-generation cryoballoon pulmonary vein isolation
    Fuernkranz, Alexander
    Bordignon, Stefano
    Schmidt, Boris
    Boehmig, Michael
    Boehmer, Marie-Christine
    Bode, Frank
    Schulte-Hahn, Britta
    Nowak, Bernd
    Dignass, Axel U.
    Chun, Julian K. R.
    [J]. HEART RHYTHM, 2013, 10 (06) : 789 - 793
  • [43] Towards a tailored cryo-pulmonary vein isolation. Lessons learned from second-generation cryoballoon ablation
    Ciconte, Giuseppe
    Coulombe, Nicolas
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    [J]. TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (07) : 420 - 425
  • [44] Incidence of early pulmonary vein reconnections using different energy sources for pulmonary vein isolation: Multielectrode phased radiofrequency vs second-generation cryoballoon
    Wieczorek, Marcus
    Tajtaraghi, Sharam
    Sassani, Kiarash
    Hoeltgen, Reinhard
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1428 - 1435
  • [45] Posterior box isolation as an adjunctive ablation strategy with the second-generation cryoballoon for paroxysmal atrial fibrillation: a comparison with standard cryoballoon pulmonary vein isolation
    Bisignani, Antonio
    Overeinder, Ingrid
    Kazawa, Shuichiro
    Iacopino, Saverio
    Cecchini, Federico
    Miraglia, Vincenzo
    Osorio, Thiago Guimaraes
    Boveda, Serge
    Bala, Gezim
    Mugnai, Giacomo
    Monaco, Cinzia
    Stroker, Erwin
    Brugada, Pedro
    Sieira, Juan
    Galli, Alessio
    de Asmundis, Carlo
    Chierchia, Gian Battista
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 61 (02) : 313 - 319
  • [46] Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon-compared to radiofrequency-based pulmonary vein isolation
    Obergassel, J.
    Nies, M.
    Taraba, S.
    Rottner, L.
    Lemoine, M. D.
    My, I.
    Moser, F.
    Riess, J. L.
    Schenker, N.
    Dinshaw, L.
    Schleberger, R.
    Reissmann, B.
    Meyer, C.
    Willems, S.
    Rillig, A.
    Kirchhof, P.
    Metzner, A.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (09) : 1766 - 1778
  • [47] Validation of electrical ostial pulmonary vein isolation verified with a spiral inner lumen mapping catheter during second-generation cryoballoon ablation
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Taniguchi, Hiroshi
    Nakamura, Hiroaki
    Hamaya, Rikuta
    Kusa, Shigeki
    Igarashi, Miyako
    Hachiya, Hitoshi
    Hirao, Kenzo
    Iesaka, Yoshito
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (08) : 870 - 875
  • [48] Pulmonary vein isolation implemented by second-generation cryoballoon for treating hypertrophic cardiomyopathy patients with symptomatic atrial fibrillation: a case-control study
    Cao, Zhong-Jing
    Guo, Xiao-Gang
    Sun, Qi
    Yang, Jian-Du
    Wei, Hui-Qiang
    Zhang, Shu
    Ma, Jian
    [J]. JOURNAL OF GERIATRIC CARDIOLOGY, 2020, 17 (08) : 476 - 485
  • [49] Left phrenic nerve injury during electrical isolation of left-sided pulmonary veins with the second-generation cryoballoon
    Okishige, Kaoru
    Aoyagi, Hideshi
    Nishimura, Takurou
    Shigeta, Takatoshi
    Keida, Takehiko
    Yamauchi, Yasuteru
    Sasano, Tetsuo
    Hirao, Kenzo
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (12): : 1426 - 1431
  • [50] Dosing of the second-generation cryoballoon using acute time-to-pulmonary vein isolation as an indicator of durable ablation in a canine model
    Su, Wilber
    Coulombe, Nicolas
    Kirchhof, Nicole
    Grassl, Erin
    Wittenberger, Dan
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 293 - 300