Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI

被引:8
作者
Battiston, Marco [1 ]
Schneider, Torben [2 ]
Grussu, Francesco [1 ,3 ]
Yiannakas, Marios C. [1 ]
Prados, Ferran [1 ,4 ,5 ]
De Angelis, Floriana [1 ]
Wheeler-Kingshott, Claudia A. M. Gandini [1 ,6 ,7 ]
Samson, Rebecca S. [1 ]
机构
[1] UCL, Fac Brain Sci, UCL Inst Neurol, Queen Sq MS Ctr,Dept Neuroinflammat, London, England
[2] Philips UK, Guildford, Surrey, England
[3] UCL, Dept Comp Sci, Ctr Med Image Comp, London, England
[4] UCL, Dept Med Phys & Biomed Engn, Ctr Med Image Comp, London, England
[5] Univ Oberta Catalunya, Barcelona, Spain
[6] Univ Pavia, Dept Brain & Behav Sci, Pavia, Italy
[7] IRCCS Mondino Fdn, Brain MRI 3T Res Ctr, Pavia, Italy
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
2-pool model; bound pool fraction; EPI; magnetization transfer; myelin; quantitative steady-state; INHOMOGENEOUSLY BROADENED LINES; QUANTITATIVE INTERPRETATION; INVERSION-RECOVERY; TRANSFER CONTRAST; HIGH-RESOLUTION; MYELIN CONTENT; SIZE RATIO; RELAXATION; BRAIN; MODEL;
D O I
10.1002/mrm.27792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain. Theory and Methods: The theory of steady-state MT in the fast-exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time (T-2(B)). A sequence that allows sampling of the signal during steady-state MT saturation is used to perform BPF mapping with a 10-min-long fully echo planar imaging-based MRI protocol, including inversion recovery T-1 mapping and B-1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single-slice full qMT reference acquisition. Results: BPF measurements are in agreement with literature values using off-resonance MT, with average BPF of 0.114(0.100-0.128) in white matter and 0.068(0.054-0.085) in gray matter. Median voxel-wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81-0.85) and 0.013(0.11-0.16). Bland-Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions. Conclusion: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.
引用
收藏
页码:1025 / 1040
页数:16
相关论文
共 44 条
[1]   A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features [J].
Alexander, Daniel C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) :439-448
[2]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[3]  
Battiston M, 2018, MAGN RESON MED, V79, P2142, DOI [10.1002/mrm.26909, 10.1002/mrm.26852]
[4]  
Bernstein M A, 2004, HDB MRI PULSE SEQUEN
[5]   B1 Mapping for Bias-Correction in Quantitative T1 Imaging of the Brain at 3T Using Standard Pulse Sequences [J].
Boudreau, Mathieu ;
Tardif, Christine L. ;
Stikov, Nikola ;
Sled, John G. ;
Lee, Wayne ;
Pike, G. Bruce .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) :1673-1682
[6]   Geodesic Information Flows: Spatially-Variant Graphs and Their Application to Segmentation and Fusion [J].
Cardoso, M. Jorge ;
Modat, Marc ;
Wolz, Robin ;
Melbourne, Andrew ;
Cash, David ;
Rueckert, Daniel ;
Ourselin, Sebastien .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (09) :1976-1988
[7]   Optimization of selective inversion recovery magnetization transfer imaging for macromolecular content mapping in the human brain [J].
Dortch, Richard D. ;
Bagnato, Francesca ;
Gochberg, Daniel F. ;
Gore, John C. ;
Smith, Seth A. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) :1824-1835
[8]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[9]   Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times [J].
Gochberg, Daniel F. ;
Gore, John C. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :437-441
[10]   FAT SUPPRESSION BY SECTION-SELECT GRADIENT REVERSAL ON SPIN-ECHO MR IMAGING - WORK IN PROGRESS [J].
GOMORI, JM ;
HOLLAND, GA ;
GROSSMAN, RI ;
GEFTER, WB ;
LENKINSKI, RE .
RADIOLOGY, 1988, 168 (02) :493-495