Osseointegration effects of local release of strontium ranelate from implant surfaces in rats

被引:20
|
作者
Alenezi, Ali [1 ,2 ]
Galli, Silvia [1 ]
Atefyekta, Saba [3 ]
Andersson, Martin [3 ]
Wennerberg, Ann [4 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, Malmo, Sweden
[2] Qassim Univ, Coll Dent, Dept Prosthodont, Buraydah, Saudi Arabia
[3] Chalmers Univ Technol, Dept Chem & Chem Engn, Gothenburg, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Odontol, Dept Prosthodont Dent Mat Sci, Gothenburg, Sweden
关键词
MESOPOROUS BIOACTIVE GLASSES; MAINTAINING BONE-FORMATION; TITANIA THIN-FILMS; VERTEBRAL FRACTURE; ANIMAL-MODELS; PORE-SIZE; COATINGS; OSTEOBLAST; RESORPTION; TOPOGRAPHY;
D O I
10.1007/s10856-019-6314-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Numerous studies have reported the beneficial effects of strontium on bone growth, particularly by stimulating osteoblast proliferation and differentiation. Thus, strontium release around implants has been suggested as one possible strategy to enhance implant osseointegration. Aim This study aimed to evaluate whether the local release of strontium ranelate (Sr-ranelate) from implants coated with mesoporous titania could improve bone formation around implants in an animal model. Materials and methods Mesoporous titania (MT) thin coatings were formed utilizing the evaporation induced self-assembly (EISA) method using Pluronic (P123) with or without the addition of poly propylene glycol (PPG) to create materials with two different pore sizes. The MT was deposited on disks and mini-screws, both made of cp Ti grade IV. Scanning electron microscopy (SEM) was performed to characterize the MT using a Leo Ultra55 FEG instrument (Zeiss, Oberkochen, Germany). The MT was loaded with Sr-ranelate using soaking and the drug uptake and release kinetics to and from the surfaces were evaluated using quartz crystal microbalance with dissipation monitoring (QCM-D) utilizing a Q-sense E4 instrument. For the in vivo experiment, 24 adult rats were analyzed at two time points of implant healing (2 and 6 weeks). Titanium implants shaped as mini screws were coated with MT films and divided into two groups; supplied with Sr-ranelate (test group) and without Sr-ranelate (control group). Four implants (both test and control) were inserted in the tibia of each rat. The in vivo study was evaluated using histomorphometric analyses of the implant/bone interphase using optical microscopy. Results SEM images showed the successful formation of evenly distributed MT films covering the entire surface with pore sizes of 6 and 7.2 nm, respectively. The QCM-D analysis revealed an absorption of 3300 ng/cm(2) of Sr-ranelate on the 7.2 nm MT, which was about 3 times more than the observed amount on the 6 nm MT (1200 ng/cm(2)). Both groups showed sustained release of Sr-ranelate from MT coated disks. The histomorphometric analysis revealed no significant differences in bone implant contact (BIC) and bone area (BA) between the implants with Sr-ranelate and implants in the control groups after 2 and 6 weeks of healing (BIC with a p-value of 0.43 after 2 weeks and 0.172 after 6 weeks; BA with a p-value of 0.503 after 2 weeks, and 0.088 after 6 weeks). The mean BIC and BA values within the same group showed significant increase among all groups between 2 and 6 weeks. Conclusion This study could not confirm any positive effects of Sr-ranelate on implant osseointegration. [GRAPHICS] .
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Osseointegration on metallic implant surfaces: Effects of microgeometry and growth factor treatment
    Frenkel, SR
    Simon, J
    Alexander, H
    Dennis, M
    Ricci, JL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (06): : 706 - 713
  • [22] Effects of strontium and cobalt codoped nanotube implants on osseointegration in osteoporotic rats
    Yang, Yaoyao
    Huang, Xin
    Zhang, Qianqian
    Zheng, Dehua
    Gong, Wen
    Niu, Shuqiang
    Yu, Yanling
    Song, Yu
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [23] Effects of strontium and cobalt codoped nanotube implants on osseointegration in osteoporotic rats
    Yang, Yaoyao
    Huang, Xin
    Zhang, Qianqian
    Zheng, Dehua
    Gong, Wen
    Niu, Shuqiang
    Yu, Yanling
    Song, Yu
    Materials Today Communications, 2022, 33
  • [24] A comparative study of strontium-substituted hydroxyapatite coating on implant's osseointegration for osteopenic rats
    Tao, Zhou-Shan
    Bai, Bing-Li
    He, Xing-Wen
    Liu, Wei
    Li, Hang
    Zhou, Qiang
    Sun, Tao
    Huang, Zheng-Liang
    Tu, Kai-kai
    Lv, Yang-Xun
    Cui, Wei
    Yang, Lei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (12) : 1959 - 1968
  • [25] IN VIVO EFFECTS OF STRONTIUM RANELATE ON BONE MARROW PROGENITOR CELLS OF DIABETIC RATS
    Berenice Lino, Agustina
    Manuel Fernandez, Juan
    Silvina Molinuevo, Maria
    Maria Cortizo, Ana
    Desmond McCarthy, Antonio
    ACTUALIZACIONES EN OSTEOLOGIA, 2016, 12 (02) : 78 - 86
  • [26] Enhancement of Local Osseointegration and Implant Stability of Titanium Implant in Osteoporotic Rats by Biomimetic Multilayered Structures Containing Catalpol
    Yang, Jiayi
    Zhang, Wei
    Lin, Binghao
    Mao, Shuming
    Liu, Guangyao
    Tan, Kai
    Tang, Jiahao
    ACS OMEGA, 2024, : 29544 - 29556
  • [27] Development of local strontium ranelate delivery systems and long term in vitro drug release studies in osteogenic medium
    Loca, Dagnija
    Smirnova, Anastasija
    Lacs, Janis
    Dubnika, Arita
    Vecstaudza, Jana
    Stipniece, Liga
    Makarova, Elina
    Dambrova, Maija
    SCIENTIFIC REPORTS, 2018, 8
  • [28] Effects of Low-Intensity Pulsed Ultrasound on Implant Osseointegration in Ovariectomized Rats
    Zhou, Hongbo
    Hou, Yongfu
    Zhu, Zhimin
    Xiao, Weixiong
    Xu, Qian
    Li, Lei
    Li, Xin
    Chen, Wenchuan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (04) : 747 - 754
  • [29] Development of local strontium ranelate delivery systems and long term in vitro drug release studies in osteogenic medium
    Dagnija Loca
    Anastasija Smirnova
    Janis Locs
    Arita Dubnika
    Jana Vecstaudza
    Liga Stipniece
    Elina Makarova
    Maija Dambrova
    Scientific Reports, 8
  • [30] Effects of local delivery of bFGF from PLGA microspheres on osseointegration around implants in diabetic rats
    Zou, Gui-Ke
    Song, Ying-Liang
    Zhou, Wei
    Yu, Miao
    Liang, Li-Hua
    Sun, Dao-Cai
    Li, De-Hua
    Deng, Zai-Xi
    Zhu, Wen-Zhong
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (03): : 284 - 289