Single dose Intravenous Tranexamic acid may not be adequate to reduce blood loss and blood transfusion requirement in patients undergoing single stage bilateral total knee arthroplasty

被引:1
作者
Mukherjee, Somnath [1 ]
Tripathy, Sujit Kumar [1 ]
Maiti, Rituparna [1 ]
Nayak, Chandrakanta [1 ]
Samal, Barada P. [1 ]
Rao, Bhaskar [1 ]
Panda, Aparajita [1 ]
机构
[1] All India Inst Med Sci, Dept Orthopaed, Bhubaneswar 751019, India
来源
ACTA ORTHOPAEDICA BELGICA | 2019年 / 85卷 / 03期
关键词
tranexamic acid; total knee replacement; arthroplasty; blood loss; blood transfusion; SAFETY; REPLACEMENT; EFFICACY; FIBRINOLYSIS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Simultaneous bilateral total knee arthroplasty (TKA) causes increased blood loss and increases the risk of venous thromboembolism. Tranexamic acid (TXA) is commonly used to minimize blood loss and transfusion requirements. However, the optimal regimen of TXA in single stage bilateral TKA is still not defined. In this retrospective study, 35 patients who received TXA and 31 patients who did not receive TXA were evaluated for blood loss and transfusion requirement. Both the groups were comparable in terms of age, sex, body mass index and preoperative haemoglobin (Hb) and haematocrit (Hct). There was no significant difference in the change in Hb levels (2.42 +/- 1.28 vs 2.44 +/- 1.31; p=0.95) and Hct (1.37 +/- 0.96 vs 1.62 +/- 0.98, p=0.22) between the groups. There were no significant differences between the study and control groups in the intraoperative blood loss (163.71 vs 165.32 ml, p=0.92), drain output (621.71 vs 695.65 ml, p=0.65) and total blood loss (785.0 vs 860.97, p=0.40). There was no significant difference in allogeneic blood transfusion between the groups (62.85% received blood in the study group vs 58.06% in the control group, p>0.05). Single intraoperative dose of TXA may not be adequate to reduce blood loss and blood transfusion requirement in bilateral TKA.
引用
收藏
页码:364 / 372
页数:9
相关论文
共 32 条
  • [1] Tranexamic acid reduces blood transfusion in total knee arthroplasty even when a blood conservation program is applied
    Alvarez, Juan C.
    Santiveri, Francisco X.
    Ramos, Isabel
    Vela, Enrique
    Puig, Lluis
    Escolano, Fernando
    [J]. TRANSFUSION, 2008, 48 (03) : 519 - 525
  • [2] Belayneh T, 2013, J BLOOD TRANSFUS, V2013
  • [3] The effect of tranexamic acid on local and plasma fibrinolysis during total knee arthroplasty
    Benoni, G
    Lethagen, S
    Fredin, H
    [J]. THROMBOSIS RESEARCH, 1997, 85 (03) : 195 - 206
  • [4] Fibrinolytic inhibition with tranexamic acid reduces blood loss and blood transfusion after knee arthroplasty - A prospective, randomised, double-blind study of 86 patients
    Benoni, G
    Fredin, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03): : 434 - 440
  • [5] Chen X, 2016, J ARTHROPLASTY
  • [6] Tranexamic acid for control of blood loss in bilateral total knee replacement in a single stage
    Dhillon, Mandeep S.
    Bali, Kamal
    Prabhakar, Sharad
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (02) : 148 - 152
  • [7] PHARMACOKINETICS OF TRANEXAMIC ACID AFTER INTRAVENOUS ADMINISTRATION TO NORMAL VOLUNTEERS
    ERIKSSON, O
    KJELLMAN, H
    PILBRANT, A
    SCHANNONG, M
    [J]. EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1974, 7 (05) : 375 - 380
  • [8] Effect of tranexamic acid on blood loss and transfusion requirement in total knee replacement in the Indian population: A case series
    Gautam, Parshotam Lal
    Katyal, Sunil
    Yamin, Mohammad
    Singh, Amandip
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2011, 55 (06) : 590 - 593
  • [9] Single perioperative dose of tranexamic acid in primary hip and knee arthroplasty
    George D.A.
    Sarraf K.M.
    Nwaboku H.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (1) : 129 - 133
  • [10] Tranexamic acid decreases external blood loss but not hidden blood loss in total knee replacement
    Good, L
    Peterson, E
    Lisander, B
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) : 596 - 599