Trabecular Metal Augments for Severe Acetabular Defects in Revision Hip Arthroplasty: A Long-Term Follow-Up

被引:22
|
作者
Russell, Shane P. [1 ,2 ]
O'Neill, Cathleen J. [1 ,2 ]
Fahey, Eoin J. [1 ,2 ]
Guerin, Shane [1 ,3 ]
Gul, Rehan [1 ,3 ]
Harty, James A. [1 ,3 ]
机构
[1] Victoria Univ Hosp, Dept Trauma & Orthopaed, South Infirm, Cork, Ireland
[2] Royal Coll Surgeons Ireland, Dublin, Ireland
[3] Univ Coll Cork, Cork, Ireland
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 05期
关键词
trabecular metal augments; revision hip arthroplasty; acetabular defects; hip center of rotation; osseointegration; osteolysis; BONE LOSS; COMPONENT; SELECTION;
D O I
10.1016/j.arth.2020.12.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Paprosky type IIIa and IIIb acetabular defects remain technically challenging during revision hip arthroplasty. Numerous surgical options exist to counter extensive acetabular bone loss with high postoperative complication and revision rates reported. Our aim was to report comprehensive long-term outcomes of our experience with Trabecular Metal (TM) augments for these difficult cases. Methods: 38 patients underwent revision total hip arthroplasty at our institution from 2009 to 2014 where a TM augment was used for acetabular deficiency. Prospective radiographic and Patient-Reported Outcome Measures were recorded and analyzed to a mean of 7.3 years (range: 5.4 to 10.8). Results: No patient was excluded or lost to follow-up. Complications included 3 intraoperative fractures, 1 early infection requiring washout with implant retention, 1 early revision due to allograft resorption, and 6 patients who required late repeat revision surgery: 3 for late infection, 2 for aseptic loosening with augment fracture or dislocation, and 1 for recurrent dislocation. The estimated mean implant survivorship was 8.99 years. 93.5% of augments remaining were well osseointegrated while 97% of the acetabular shells were osseointegrated. Hip center of rotation was restored by a mean of 14 mm inferiorly without significant medialization. Short Form-12 (SF-12) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were significantly reduced postoperatively to a level comparable to the average individual. Conclusion: This long-term study details our experience of TM augments for the most severe acetabular defects. For such cases, no excellent surgical solution exists; in comparison to alternative methods, we advocate that this technique is reasonably safe and effective. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1740 / 1745
页数:6
相关论文
共 50 条
  • [31] Use of Customized 3D-Printed Titanium Augment With Tantalum Trabecular Cup for Large Acetabular Bone Defects in Revision Total Hip Arthroplasty: A Midterm Follow-Up Study
    Kong, Keyu
    Zhao, Chen
    Chang, Yongyun
    Qiao, Hua
    Hu, Yi
    Li, Huiwu
    Zhang, Jingwei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [32] Highly cross-linked polyethylene in hip resurfacing arthroplasty: long-term follow-up
    Amstutz, Harlan C.
    Takamura, Karren M.
    Ebramzadeh, Edward
    Le Duff, Michel J.
    HIP INTERNATIONAL, 2015, 25 (01) : 39 - 43
  • [33] Mid-term Follow-up of the Direct Anterior Approach in Acetabular Revision Hip Arthroplasty Using a Reconstruction Cage With Impaction Grafting
    Thaler, Martin
    Dammerer, Dietmar
    Leitner, Hermann
    Lindtner, Richard A.
    Nogler, Michael
    JOURNAL OF ARTHROPLASTY, 2020, 35 (05): : 1339 - 1343
  • [34] Cemented Hip Revision Surgery in Severe Acetabular Defects Using a Semirigid Acetabular Reinforcement Ring-a 5-to 25-Year Follow-Up Study
    Haverkamp, Daniel
    De Man, F. Harald R.
    Slegt, Raoul
    Besselaar, Philip P.
    Marti, Rene K.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (02): : 246 - 255
  • [35] Custom Triflange Acetabular Components for Revision Hip Arthroplasty in the Patients with Severe Acetabular Defects: Planning, Surgical Technique, Outcomes
    Korytkin, A. A.
    Novikova, Ya. S.
    Morozova, E. A.
    Gerasimov, S. A.
    Kovaldov, K. A.
    El Moudni, Yo. M.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2020, 26 (02): : 20 - 30
  • [36] A modified custom-made triflanged acetabular reconstruction ring (MCTARR) for revision hip arthroplasty with severe acetabular defects
    Colen, Sascha
    Harake, Ramzi
    De Haan, Julien
    Muleir, Michiel
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 71 - 75
  • [37] Mid-term results in revision hip arthroplasty with impaction bone grafted cup reconstruction for acetabular defects
    Rohe, Sebastian
    Doerr, Nicoletta
    Boehle, Sabrina
    Matziolis, Georg
    Brodt, Steffen
    Roehner, Eric
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [38] Hip Arthroplasty With the Use of a Reconstruction Cage and Porous Metal Augment to Treat Massive Acetabular Bone Loss: A Midterm Follow-Up
    Garceau, Simon P.
    Warschawski, Yaniv
    Joly, Denis
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S636 - S641
  • [39] Long-term results of isolated acetabular revisions with reinforcement rings: a 10-to 15-year follow-up
    Marongiu, Giuseppe
    Podda, Daniele
    Mastio, Michele
    Capone, Antonio
    HIP INTERNATIONAL, 2019, 29 (04) : 385 - 392
  • [40] Three-dimensional-printed titanium implants for severe acetabular bone defects in revision hip arthroplasty: short- and mid-term results
    Fang, Sheng
    Wang, Yiming
    Xu, Peng
    Zhu, Junke
    Liu, Jinbo
    Li, Huan
    Sun, Xiaoliang
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (06) : 1289 - 1297