The SLIM spectrometer

被引:33
作者
Cantrell, KM [1 ]
Ingle, JD [1 ]
机构
[1] Oregon State Univ, Dept Chem, Corvallis, OR 97331 USA
关键词
D O I
10.1021/ac026015s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new spectrometer, here denoted the SLIM (simple, low-power, inexpensive, microcontroller-based) spectrometer, was developed that exploits the small size and low cost of solid-state electronic devices. In this device, light-emitting diodes (LED), single-chip integrated circuit photodetectors, embedded microcontrollers, and batteries replace traditional optoelectronic components, computers, and power supplies. This approach results in complete customizable spectrometers that are considerably less expensive and smaller than traditional instrumentation. The performance of the SLIM spectrometer, configured with a flow cell, was evaluated and compared to that of a commercial spectrophotometer. Thionine was the analyte, and the detection limit was similar to0.2 muM with a 1.5-mm-path length flow cell. Nonlinearity due to the broad emission profile of the LED light sources is discussed.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 12 条
[1]  
CANTRELL K, 2001, THESIS OREGON STATE
[2]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF NITRATE [J].
CLINCH, JR ;
WORSFOLD, PJ ;
CASEY, H .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :523-531
[3]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF AMMONIA [J].
CLINCH, JR ;
WORSFOLD, PJ ;
SWEETING, FW .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :401-407
[4]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[5]  
Hauser PC, 1995, CHIMIA, V49, P492
[6]   A MULTIWAVELENGTH PHOTOMETER BASED ON LIGHT-EMITTING-DIODES [J].
HAUSER, PC ;
RUPASINGHE, TWT ;
CATES, NE .
TALANTA, 1995, 42 (04) :605-612
[7]   A DUAL-WAVELENGTH LIGHT-EMITTING DIODE BASED DETECTOR FOR FLOW-INJECTION ANALYSIS PROCESS ANALYZERS [J].
HUANG, JL ;
LIU, HH ;
TAN, AM ;
XU, JH ;
ZHAO, XN .
TALANTA, 1992, 39 (06) :589-592
[8]   Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell [J].
Jambunathan, S ;
Dasgupta, PK ;
Wolcott, DK ;
Marshall, GD ;
Olson, DC .
TALANTA, 1999, 50 (03) :481-490
[9]   Evaluation of immobilized redox indicators as reversible, in situ redox sensors for determining Fe (III)-reducing conditions in environmental samples [J].
Jones, BD ;
Ingle, JD .
TALANTA, 2001, 55 (04) :699-714
[10]   Development of redox sensors for environmental applications based on immobilized redox indicators [J].
Lemmon, TL ;
Westall, JC ;
Ingle, JD .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :947-953