Purpose. Evaluation of postoperative artificial iris prosthesis-related complications. Design. Retrospective cohort study. Methods. Fifty-one consecutive patients underwent pupillary reconstruction using an artificial iris implant made from silicone between 2011 and 2015. Quantity and quality of complications were subclassified into three groups including mild, moderate, and severe complications. Their management and the learning curve were evaluated. Results. In total, 13 (25.5%) of 51 included artificial iris implantations showed unexpected events in various degrees: mild complications: recurrent bleeding (n = 1, 2.0%), slight but stable iris deviation (n = 1, 2.0%), capsular fibrosis (n = 2, 3.9%); moderate complications: suture cutting through the residual iris (n = 1, 2.0%), glaucoma (n = 3, 5.9%), and corneal decompensation (n = 3, 5.9%); severe complications: artificial iris suture loosening (n = 2, 3.9%) and dislocation (n = 3, 5.9%), synechiae (n = 2, 3.9%), glaucoma (n = 2, 3.9%), and corneal decompensation (n = 5, 9.8%) with the need for surgery, cystoid macular edema (n = 3, 5.9%) and retinal detachment (n = 1, 2.0%). 'I he complication rate decreased from 83.3% (5 of 6 implantations) in the first year to 13.3% (2 of 15 implantations) in the 4th year. Nineteen of 45 evaluated patients showed a significant gain in best-corrected visual acuity (BCVA) from 1.09 t 0.56 logMAR to 0.54 +/- 0.48 logMAR (p < 0.001), and 13 of 45 eyes had a significant BCVA loss from 0.48 1 0.39 logMAR to 0.93 1 0.41 logMAR after surgery (p < 0.001). Conclusions. The artificial iris is a feasible option in the treatment of iris defects with a wide spectrum of postoperative complications. The significant reduction of complications after twelve implantations implicates that the procedure is not to be recommended in low volume settings.
引用
收藏
页数:10
相关论文
共 25 条
  • [1] Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation
    Forlini, Cesare
    Forlini, Matteo
    Rejdak, Robert
    Prokopiuk, Agata
    Levkina, Oxana
    Bratu, Adriana
    Rossini, Paolo
    Cagampang, Perfecto R., III
    Cavallini, Gian Maria
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (03) : 667 - 675
  • [2] Artificial iris after severe trauma of the orbit
    Haritoglou, C.
    [J]. OPHTHALMOLOGE, 2015, 112 (07): : 599 - 601
  • [3] Implantation of an Artificial Iris in 11 Patients
    Kniestedt, C.
    Eberhard, R.
    Fleischhauer, J.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (04) : 365 - 368
  • [4] Artificial iris devices: Benefits, limitations, and management of complications
    Koch, Konrad R.
    Heindl, Ludwig M.
    Cursiefen, Claus
    Koch, Hans-Reinhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (03) : 376 - 382
  • [5] Acute angle-closure attack secondary to BrightOcular cosmetic iris implant and subsequent subluxation of contralateral iris implant
    Le Du, B.
    Boukhrissa, M.
    Nordmann, J. -P.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (06): : E141 - E144
  • [6] Modified implantation of black diaphragm intraocular lens in traumatic aniridia
    Li, Jun
    Yuan, Gongqiang
    Ying, Liang
    Yu, Bin
    Dong, Xiaoguang
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) : 822 - 825
  • [7] Safety of an artificial iris in a phakic eye
    Magnus, Jessy
    Trau, Rene
    Mathysen, Danny G. P.
    Tassignon, Marie-Jose
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) : 1097 - 1100
  • [8] Iritis, glaucoma and corneal decompensation associated with BrightOcular cosmetic iris implant
    Mansour, Ahmad M.
    Ahmed, Iqbal Ike K.
    Eadie, Brennan
    Chelala, Elias
    Saade, Joanna S.
    Slade, Stephen G.
    Mearza, Ali A.
    Parmar, Dipak
    Ghabra, Marwan
    Luk, Sheila
    Kelly, Alla
    Kaufman, Stephen C.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) : 1098 - 1101
  • [9] Mayer CS, 2015, OPHTHALMOLOGE, V112, P865, DOI 10.1007/s00347-015-0123-6
  • [10] Artificial iris implantation in various iris defects and lens conditions
    Mayer, Christian
    Tandogan, Tamer
    Hoffmann, Andrea E.
    Khoramnia, Ramin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) : 724 - 731