Long-term assessment of crystalline lens transparency in eyes implanted with a central-hole phakic collamer lens developing low postoperative vault

被引:34
作者
Gonzalez-Lopez, Felix [1 ]
Bouza-Miguens, Carmen [1 ]
Tejerina, Victor [1 ]
Mompean, Blas [2 ]
Ortega-Usobiaga, Julio [3 ]
Bilbao-Calabuig, Rafael [1 ]
机构
[1] Clin Baviera, Dept Refract Surg, Melchor Fernandez Almagro 9, Madrid 28029, Spain
[2] Clin Baviera, Dept Refract Surg, Murcia, Spain
[3] Clin Baviera, Dept Refract Surg, Bilbao, Spain
关键词
INTRAOCULAR-LENS; CENTRAL PORT; FLUID-DYNAMICS; AQUEOUS-HUMOR; HIGH MYOPIA; IOL ICL; CATARACT; MODERATE; INSERTION; PRESSURE;
D O I
10.1097/j.jcrs.0000000000000425
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess long-term crystalline lens transparency in eyes implanted with phakic collamer intraocular lens (pIOL) with a central port and low postoperative vault for correction of myopia. Setting: Clinica Baviera, Madrid, Spain. Design: Retrospective cross-sectional single-center study. Methods: Using a noninvasive Fourier-domain swept-source anterior segment optical coherence tomography system, shifts in myopic and astigmatic myopic eyes implanted with a pIOL with vaulting lower than 100 mu m in miosis and more than 4 years of follow-up were dynamically evaluated. Main outcome measures were pIOL dynamic vault (vault interval and vault range [VR]), crystalline lens density, and anterior subcapsular lens opacities. Crystalline lenses were examined under slitlamp microscopy, and lens density was evaluated using quantitative Scheimpflug images. Scheimpflug images were compared with those of a control group comprising eyes that were candidates for pIOL implantation. Results: The study population comprised 24 eyes from 16 patients previously implanted with a pIOL (5.82 +/- 0.9 years) with central vault lower than 100 mu m under photopically induced miosis. The mean vault value was 52 +/- 19 mu m under photopic light conditions and 113 +/- 37 mu m under scotopic conditions. The mean VR was 58 +/- 24 mu m. Anterior subcapsular lens opacities were found in only 1 eye (4.17%). The mean lens density was 7.94 +/- 0.43, and no statistically significant differences were observed compared with the control group. Conclusions: Long-term low vaulting in eyes implanted with a pIOL with a central port for correction of myopia was associated with a low risk for developing anterior crystalline lens opacities.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 33 条
[1]   Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design [J].
Alfonso, Jose F. ;
Fernandez-Vega-Cueto, Luis ;
Alfonso-Bartolozzi, Belen ;
Montes-Mico, Robert ;
Fernandez-Vega, Luis .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) :169-+
[2]   Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega, Luis ;
Almanzar, Dagoberto ;
Perez-Vives, Cari ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04) :800-805
[3]  
[Anonymous], 2005, Introduction to robust estimation and hypothesis testing
[4]   Long-term follow-up of persistent low vault after implantable collamer lens exchange [J].
Cordoba, Andrea ;
Graue-Hernandez, Enrique O. ;
Gomez-Bastar, Arturo ;
Navas, Alejandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04) :519-522
[5]   Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications [J].
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :765-776
[6]   Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye [J].
Fujisawa, Kunitoshi ;
Shimizu, Kimiya ;
Uga, Shigekazu ;
Suzuki, Masanobu ;
Nagano, Koichi ;
Murakami, Yuuki ;
Goseki, Hiroko .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) :114-122
[7]   Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation [J].
Gonvers, M ;
Bornet, C ;
Othenin-Girard, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :918-924
[8]   Determining the Potential Role of Crystalline Lens Rise in Vaulting in Posterior Chamber Phakic Collamer Lens Surgery for Correction of Myopia [J].
Gonzalez-Lopez, Felix ;
Bilbao-Calabuig, Rafael ;
Mompean, Blas ;
Luezas, Jorge ;
Ortega-Usobiaga, Julio ;
Druchkiv, Vasyl .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) :177-+
[9]   Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study [J].
Gonzalez-Lopez, Felix ;
Mompean, Blas ;
Bilbao-Calabuig, Rafael ;
Vila-Arteaga, Jorge ;
Beltran, Jaime ;
Baviera, Julio .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03)
[10]   Pupillary block glaucoma secondary to central port occlusion following insertion of a phakic implantable copolymer lens [J].
Gonzalez-Lopez, Felix ;
Bilbao-Calabuig, Rafael ;
Alen, Ricardo ;
Mompean, Blas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (11) :1468-1470