Including Indoor Offgassed Emissions in the Life Cycle Inventories of Wood Products

被引:37
作者
Chaudhary, Abhishek [1 ]
Hellweg, Stefanie [1 ]
机构
[1] ETH, Inst Environm Engn, CH-8093 Zurich, Switzerland
关键词
ORGANIC-COMPOUNDS; IMPACT ASSESSMENT; VOC EMISSIONS; FORMALDEHYDE EMISSION; HEALTH EVALUATION; INTAKE FRACTION; PANELS; RATES;
D O I
10.1021/es5045024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Volatile organic compounds (VOCs) that negatively affect human health are emitted from wood products used indoors. However, the existing life cycle inventories of these products only document the emissions occurring during production and disposal phases. Consequently, the life cycle assessment (LCA) of indoor wooden products conducted using these inventories neglect the use-phase impacts from exposure to offgassed VOCs and therefore underestimate the products total environmental impact. This study demonstrates a methodology to calculate the use phase inventory and the corresponding human health impacts resulting from indoor use of any VOC emitting product. For the five most commonly used types of boards used in indoor wood products, the mass of each VOC emitted into the indoor compartment over their service life was calculated by statistically analyzing data from 50 published chamber testing studies. Uncertainty was assessed using Monte Carlo simulations. The calculated inventory data were used in a case study to calculate and compare the health impacts of five different wooden floorings made of above materials. The results show that the use-phase human-toxicity impacts are an order of magnitude higher than those occurring during the rest of the floorings life cycle. The factors influencing the offgassing of VOCs from wood products and measures to reduce exposure are discussed.
引用
收藏
页码:14607 / 14614
页数:8
相关论文
共 34 条
[1]   Service life prediction of residential interior finishes for life cycle assessment [J].
Aktas, Can B. ;
Bilec, Melissa M. .
INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2012, 17 (03) :362-371
[2]  
[Anonymous], 2012, HEALTH RELATED EVALU
[3]  
[Anonymous], 2006, ISO 16000 9
[4]   Defining intake fraction [J].
Bennett, DH ;
McKone, TE ;
Evans, JS ;
Nazaroff, WW ;
Margni, MD ;
Jolliet, O ;
Smith, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (09) :206A-211A
[5]   Chamber assessment of formaldehyde and VOC emissions from wood-based panels [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :209-215
[6]  
Funch L. W, 2002, DETERMINATION OF EMI
[7]  
Gunther A., 1997, INT J LIFE CYCLE ASS, V2, P73, DOI DOI 10.1007/BF02978763
[8]   Review of indoor emission source models. Part 1. Overview [J].
Guo, ZH .
ENVIRONMENTAL POLLUTION, 2002, 120 (03) :533-549
[9]   Formaldehyde and VOC emissions at different manufacturing stages of wood-based panels [J].
He, Zhongkai ;
Zhang, Yinping ;
Wei, Wenjuan .
BUILDING AND ENVIRONMENT, 2012, 47 :197-204
[10]   Integrating Human Indoor Air Pollutant Exposure within Life Cycle Impact Assessment [J].
Hellweg, Stefanie ;
Demou, Evangelia ;
Bruzzi, Raffaella ;
Meijer, Arien ;
Rosenbaum, Ralph K. ;
Huijbregts, Mark A. J. ;
McKone, Thomas E. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (06) :1670-1679