Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

被引:3
作者
Pinto, Ruben N. [1 ,2 ]
Bagga, Karan [1 ,3 ]
Douplik, Alexandre [1 ,2 ]
Acker, Jason P. [4 ,5 ]
Kolios, Michael C. [1 ,2 ]
机构
[1] Inst Biomed Engn Sci & Technol, Toronto, ON, Canada
[2] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[4] Canadian Blood Serv, Ctr Innovat, Edmonton, AB, Canada
[5] Univ Alberta, Dept Lab Med & Pathol, Edmonton, AB, Canada
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017 | 2017年 / 10064卷
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Blood bag; blood gas analyzer; hemoglobin; oximetry; oxygen saturation; photoacoustics; red blood cell; red cell concentrate; storage lesion; 2,3-DPG; TRANSFUSION; HEMOGLOBIN; SURVIVAL;
D O I
10.1117/12.2253530
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.
引用
收藏
页数:7
相关论文
共 20 条
[1]   A quality monitoring program for red blood cell components: in vitro quality indicators before and after implementation of semiautomated processing [J].
Acker, Jason P. ;
Hansen, Adele L. ;
Kurach, Jayme D. R. ;
Turner, Tracey R. ;
Croteau, Ioana ;
Jenkins, Craig .
TRANSFUSION, 2014, 54 (10) :2534-2543
[2]   Biomedical photoacoustic imaging [J].
Beard, Paul .
INTERFACE FOCUS, 2011, 1 (04) :602-631
[3]   INTRACELLULAR ORGANIC PHOSPHATES AS REGULATORS OF OXYGEN RELEASE BY HAEMOGLOBIN [J].
BENESCH, R ;
BENESCH, RE .
NATURE, 1969, 221 (5181) :618-&
[4]   Evolution of adverse changes in stored RBCs [J].
Bennett-Guerrero, Elliott ;
Veldman, Tim H. ;
Doctor, Allan ;
Telen, Marilyn J. ;
Ortel, Thomas L. ;
Reid, T. Scott ;
Mulherin, Melissa A. ;
Zhu, Hongmei ;
Buck, Raymond D. ;
Califf, Robert M. ;
McMahon, Timothy J. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (43) :17063-17068
[5]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[6]   Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags [J].
Buckley, K. ;
Atkins, C. G. ;
Chen, D. ;
Schulze, H. G. ;
Devine, D. V. ;
Blades, M. W. ;
Turner, R. F. B. .
ANALYST, 2016, 141 (05) :1678-1685
[7]   Red Blood Cell Transfusion: A Clinical Practice Guideline From the AABB [J].
Carson, Jeffrey L. ;
Grossman, Brenda J. ;
Kleinman, Steven ;
Tinmouth, Alan T. ;
Marques, Marisa B. ;
Fung, Mark K. ;
Holcomb, John B. ;
Illoh, Orieji ;
Kaplan, Lewis J. ;
Katz, Louis M. ;
Rao, Sunil V. ;
Roback, John D. ;
Shander, Aryeh ;
Tobian, Aaron A. R. ;
Weinstein, Robert ;
McLaughlin, Lisa Grace Swinton ;
Djulbegovic, Benjamin .
ANNALS OF INTERNAL MEDICINE, 2012, 157 (01) :49-U95
[8]   Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations [J].
Chan, Edward D. ;
Chan, Michael M. ;
Chan, Mallory M. .
RESPIRATORY MEDICINE, 2013, 107 (06) :789-799
[9]  
Chatburn R. L., 2014, EQUIPMENT RESP CARE
[10]  
DALESSANDRO A, 2010, J BLOOD TRANSFUS, V8, P82, DOI DOI 10.2450/2009.0122-09