Towards automated Laue data processing: application to the choice of optimal X-ray spectrum

被引:23
|
作者
Bourgeois, D
Wagner, U
Wulff, M
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] IBS, UPR 9015, LCCP, F-38027 Grenoble 1, France
[3] Karl Franzens Univ Graz, Inst Chem, Abt Strukturbiol, A-8010 Graz, Austria
关键词
D O I
10.1107/S0907444900006958
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Laue data reduction has now reached a level of sophistication that allows nearly automated processing to be performed. The software described enables complete reduction of the data with essentially no user intervention, making Laue processing almost as straightforward as monochromatic data processing. Interactive work is limited to the indexing of only one Laue pattern. More importantly, it is shown that the data quality is substantially enhanced when soft-limited predictions are used. Further improvement obtained by taking advantage of the structure-factor amplitudes from a known closely related structure is described. To determine the most suitable type of insertion device to be used for time-resolved Laue crystallography, the technique described was applied to Laue data sets collected from photoactive yellow protein under identical conditions but with three different insertion devices: a wiggler, a broad-bandpass undulator and a single-line undulator. Although the optimal choice may ultimately be dictated by sample parameters (such as mosaic spread) and by the type of experiment (repeatable or non-repeatable reactions), the results here show that the use of single-line undulators will generally yield by far the best compromise between data quality, acquisition time and radiation damage.
引用
收藏
页码:973 / 985
页数:13
相关论文
共 50 条
  • [21] SIMULATION OF X-RAY TRAVERSE TOPOGRAPHS AND SYNCHROTRON LAUE TOPOGRAPHS - APPLICATION OF THE RECIPROCITY THEOREM
    CARVALHO, CAM
    EPELBOIN, Y
    ACTA CRYSTALLOGRAPHICA SECTION A, 1993, 49 : 467 - 473
  • [22] Application of X-ray diffraction in Laue geometry to imperfect near-surface layers
    Kyutt, RN
    Argunova, TS
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA D-CONDENSED MATTER ATOMIC MOLECULAR AND CHEMICAL PHYSICS FLUIDS PLASMAS BIOPHYSICS, 1997, 19 (2-4): : 267 - 275
  • [23] Hard x-ray nanofocusing by multilayer Laue lenses
    Yan, Hanfei
    Conley, Ray
    Bouet, Nathalie
    Chu, Yong S.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (26)
  • [24] X-RAY LAUE DIFFRACTION FROM PROTEIN CRYSTALS
    MOFFAT, K
    SZEBENYI, D
    BILDERBACK, D
    SCIENCE, 1984, 223 (4643) : 1423 - 1425
  • [25] PHOTOEFFECT UNDER CONDITIONS OF THE X-RAY LAUE DIFFRACTION
    AFANASIEV, AM
    IMAMOV, RM
    MASLOV, AV
    PASHAEV, EM
    DOKLADY AKADEMII NAUK SSSR, 1983, 273 (03): : 609 - 612
  • [26] X-RAY FOCUSING BY THE ZONE PLATE IN LAUE GEOMETRY
    SNIGIREV, AA
    SUVOROV, AY
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (4A) : A41 - A44
  • [27] Measurement and application of original spectrum and transmission spectrum of X-ray tube
    Zhang C.
    Zhang Y.-H.
    Shang H.-J.
    Pan X.-D.
    Shao C.-J.
    Yu D.-Y.
    Luo Y.-H.
    Li G.-P.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2016, 50 (10): : 1859 - 1865
  • [28] On the x-ray spectrum
    Sommerfeld, A
    ANNALEN DER PHYSIK, 1915, 46 (06) : 721 - 748
  • [29] LAUE SPECTROMETER FOR MULTICHANNEL X-RAY SPECTROCHEMICAL ANALYSIS
    LADELL, J
    SPIELBERG, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (01): : 23 - 29
  • [30] Microdose X-Ray systems and optimal areas of their application
    Baru S.E.