Towards automated Laue data processing: application to the choice of optimal X-ray spectrum

被引:23
|
作者
Bourgeois, D
Wagner, U
Wulff, M
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] IBS, UPR 9015, LCCP, F-38027 Grenoble 1, France
[3] Karl Franzens Univ Graz, Inst Chem, Abt Strukturbiol, A-8010 Graz, Austria
关键词
D O I
10.1107/S0907444900006958
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Laue data reduction has now reached a level of sophistication that allows nearly automated processing to be performed. The software described enables complete reduction of the data with essentially no user intervention, making Laue processing almost as straightforward as monochromatic data processing. Interactive work is limited to the indexing of only one Laue pattern. More importantly, it is shown that the data quality is substantially enhanced when soft-limited predictions are used. Further improvement obtained by taking advantage of the structure-factor amplitudes from a known closely related structure is described. To determine the most suitable type of insertion device to be used for time-resolved Laue crystallography, the technique described was applied to Laue data sets collected from photoactive yellow protein under identical conditions but with three different insertion devices: a wiggler, a broad-bandpass undulator and a single-line undulator. Although the optimal choice may ultimately be dictated by sample parameters (such as mosaic spread) and by the type of experiment (repeatable or non-repeatable reactions), the results here show that the use of single-line undulators will generally yield by far the best compromise between data quality, acquisition time and radiation damage.
引用
收藏
页码:973 / 985
页数:13
相关论文
共 50 条
  • [1] Towards automated Laue data processing: application to the choice of the optimal X-ray spectrum.
    Bourgeois, D.
    Wagner, U.
    Wulff, M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2000, 56 : S296 - S296
  • [2] AUTOMATED INDEXING OF X-RAY LAUE SPOTS FOR ARBITRARY LATTICES
    OHBA, R
    YAMADA, H
    WATANABE, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1984, 23 (05): : 652 - 655
  • [3] Optimization Design of X-Ray Spectrum Data Processing Platform
    Tang Lin
    Zhao Wei-dong
    Yu Song-ke
    Liu Ze
    Yu Xiao-dong
    Meng Yuan
    Huang Xing-lu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (03) : 763 - 767
  • [4] The choice of options of the data processing of the X-ray single-crystal data
    Galdecka, E
    APPLIED CRYSTALLOGRAPHY, 2001, : 101 - 103
  • [5] X-ray data processing
    Powell, Harold R.
    BIOSCIENCE REPORTS, 2017, 37
  • [6] Hard X-ray Laue monochromator
    Kocharyan, V. R.
    Gogolev, A. S.
    Kiziridi, A. A.
    Batranin, A. V.
    Muradyan, T. R.
    VIII INTERNATIONAL SCIENTIFIC CONFERENCE - ISSUES OF PHYSICS AND TECHNOLOGY IN SCIENCE, INDUSTRY AND MEDICINE, 2016, 135
  • [7] SIMULATION OF X-RAY LAUE PATTERNS
    PLOC, RA
    JOURNAL OF MATERIALS SCIENCE, 1983, 18 (04) : 1083 - 1088
  • [8] X-ray spectrum processing and multivariate analysis
    Titchmarsh, JM
    MIKROCHIMICA ACTA, 1998, : 37 - 47
  • [9] THE LAUE-DATA-MODULE (LDM) - A SOFTWARE-DEVELOPMENT FOR LAUE X-RAY-DIFFRACTION DATA-PROCESSING
    CAMPBELL, JW
    CLIFTON, IJ
    HARDING, MM
    HAO, Q
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1995, 28 : 635 - 640
  • [10] TUNABLE LAUE BRAGGCASE X-RAY INTERFEROMETER
    SPIEKER, P
    BONSE, U
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S238 - S238