Miniature ureteroscope distal tip designs for potential use in thulium fiber laser lithotripsy

被引:21
作者
Wilson, Christopher R. [1 ]
Kennedy, Joshua D. [1 ]
Irby, Pierce B. [2 ]
Fried, Nathaniel M. [1 ,2 ]
机构
[1] Univ North Carolina Charlotte, Dept Phys & Opt Sci, Charlotte, NC 28223 USA
[2] Carolinas Med Ctr, McKay Dept Urol, Charlotte, NC 28203 USA
关键词
illumination; irrigation; laser; lithotripsy; miniature; thulium; ureteroscope; MICRO-URETEROSCOPY; CYSTOSCOPY; DEFLECTION; CHANNEL; CANCER; STONES; SYSTEM; BASKET; FLOW;
D O I
10.1117/1.JBO.23.7.076003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Thulium fiber laser lithotripsy using smaller optical fibers may enable development of miniature ureteroscopes. Two ureteroscope distal tip prototypes were built and characterized. The first design was 4.5-French (Fr) [1.5-mm outer diameter (OD)], five channel tip, housing 200-mu m inner diameter (ID) dedicated central channel for insertion of 100-mu m core fibers and four surrounding channels, each with 1.5 Fr (510-mu m ID) for instrumentation, irrigation, imaging, and illumination, respectively. The second design was 6.0-Fr (2.0-mm OD), three-dimensional printed tip with larger, hemispherical common working channel and separate detection port integrated with ring lighting. Standard instruments, including optical fibers, guidewires, and stone baskets, were inserted through working channels to demonstrate feasibility. Gravitational and manual pump-assisted saline irrigation rates were measured. Luminous intensity distribution curves (LIDCs) were modeled for both ring and conventional lighting designs. Imaging was conducted using 3000, 6000, and 10,000 pixel, miniature, flexible endoscopes with 0.4-, 0.6-, and 0.9-mm OD, to differentiate between urinary stones and ureter wall, for potential clinical application. The multichannel ureteroscope tip with 1.5-Fr working channel yielded a gravitational saline flow rate of 3.9 +/- 0.2 mL/min compared to 31.3 +/- 0.6 mL/min for standard (3.6 Fr) ureteroscope channel. Manual, pump-assisted irrigation increased flow rate to 32.5 +/- 3.0 mL/min. The 6000 pixel, 0.6-mm OD, flexible endoscope provided a balance of clear differentiation between stones and ureter wall and sufficiently small OD. A ring lighting configuration provided more uniform illumination than conventional cross-lighting geometry as demonstrated by LIDCs. With further development, these miniature ureteroscope tip designs may be integrated into a fully functional ureteroscope to permit ureteral access with minimal trauma and improved patient safety and comfort. (c) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
页数:9
相关论文
共 28 条
  • [1] Adverse Events Resulting from Lasers Used in Urology
    Althunayan, Abdulaziz M.
    Elkoushy, Mohamed A.
    Elhilali, Mostafa M.
    Andonian, Sero
    [J]. JOURNAL OF ENDOUROLOGY, 2014, 28 (02) : 256 - 260
  • [2] Working tools in flexible ureterorenoscopy - Influence on flow and deflection: What does matter?
    Bach, T.
    Geavlete, B.
    Herrmann, T. R. W.
    Gross, A. J.
    [J]. JOURNAL OF ENDOUROLOGY, 2008, 22 (08) : 1639 - 1643
  • [3] Thulium fiber laser ablation of kidney stones using a 50-μm-core silica optical fiber
    Blackmon, Richard L.
    Hutchens, Thomas C.
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    [J]. OPTICAL ENGINEERING, 2015, 54 (01)
  • [4] Thulium Fiber Laser Lithotripsy Using Tapered Fibers
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    [J]. LASERS IN SURGERY AND MEDICINE, 2010, 42 (01) : 45 - 50
  • [5] Bryan RT, 2008, BJU INT, V101, P702, DOI 10.1111/j.1464-410X.2007.07317.x
  • [6] Micro-ureteroscopy: Initial experience in the endoscopic treatment of pelvic ureteral lithiasis
    Caballero, J. P.
    Galan, J. A.
    Verges, A.
    Amoros, A.
    Garcia-Segui, A.
    [J]. ACTAS UROLOGICAS ESPANOLAS, 2015, 39 (05): : 327 - 331
  • [7] Assessment of the Effectiveness, Safety, and Reproducibility of Micro-Ureteroscopy in the Treatment of Distal Ureteral Stones in Women: A Multicenter Prospective Study
    Caballero-Romeu, Juan-Pablo
    Galan-Llopis, Juan-Antonio
    Perez-Fentes, Daniel
    Budia-Alba, Alberto
    Cepeda-Delgado, Marcos
    Palmero-Marti, Jose-Luis
    Cansino-Alcaide, Jose-Ramon
    Caballero-Perez, Pablo
    Ibarluzea-Gonzalez, Gaspar
    [J]. JOURNAL OF ENDOUROLOGY, 2016, 30 (11) : 1185 - 1193
  • [8] A New Generation of Optical Diagnostics for Bladder Cancer: Technology, Diagnostic Accuracy, and Future Applications
    Cauberg, Evelyne C. C.
    de Bruin, Daniel M.
    Faber, Dirk J.
    van Leeuwen, Ton G.
    de la Rosette, Jean J. M. C. H.
    de Reijke, Theo M.
    [J]. EUROPEAN UROLOGY, 2009, 56 (02) : 287 - 296
  • [9] Damage of Stone Baskets by Endourologic Lithotripters: A Laboratory Study of 5 Lithotripters and 4 Basket Types
    Cordes, Jens
    Nguyen, Felix
    Lange, Birgit
    Brinkmann, Ralf
    Jocham, Dieter
    [J]. ADVANCES IN UROLOGY, 2013, 2013
  • [10] Destruction of Stone Extraction Basket During an In Vitro Lithotripsy-A Comparison of Four Lithotripters
    Cordes, Jens
    Lange, Birgit
    Jocham, Dieter
    Kausch, Ingo
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 (08) : 1359 - 1362