Embrittlement behavior of zircaloy-4 cladding during oxidation and water quench

被引:19
作者
Kim, JH [1 ]
Lee, MH [1 ]
Choi, BK [1 ]
Jeong, YH [1 ]
机构
[1] Korea Atom Energy Res Inst, Zirconium Fuel Cladding Team, Taejon 305600, South Korea
关键词
D O I
10.1016/j.nucengdes.2004.08.030
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Simulated loss of coolant accident (LOCA) tests on Zircaloy-4 cladding were carried out to evaluate the thermal shock property during the injection of emergency core coolant. A Zircaloy-4 specimen was oxidized in a steam environment between 1000 and 1250 degreesC followed by a flooding of the cooling water. After the test, the ductility of the thermally embrittled specimen was measured by a ring-compression test and a microstructural analysis was carried out. The results showed that the threshold equivalent cladding reacted (ECR) value to cause a failure was higher than the conventional 17% criterion calculated by the Baker-Just equation. A residual metal thickness under 0.3 mm as well as a ring-compression ductility below 0.2 mm for a fracture is effective to assess the thermal shock embrittlement of Zircaloy-4 in an axially unrestrained, or even in a restrained condition. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 16 条
  • [1] Baker L., 1962, ANL 6548
  • [2] BIBILASHVILI YK, 2001, P TOP M LOCA FUEL SA, P175
  • [3] BOHMERT J, 1993, NUCL ENG DES, V147, P53
  • [4] Chung H.M., 1978, NUREGCR0344ANL7731
  • [5] Chung HM., 1980, Summary report
  • [6] CHUNG HM, 1996, ACRS SUBC M HIGH BUR
  • [7] A mechanism for the hydrogen uptake process in zirconium alloys
    Cox, B
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1999, 264 (03) : 283 - 294
  • [8] Erbacher F., 1987, Zircon. Nucl. Ind., V939, P451
  • [9] HACHE G, 2000, P 28 WAT REACT SAF M, P205
  • [10] HACHE G, 2001, TCM FUEL BEH TRANS L