Increased sensitivity and confidence of SPECT over planar imaging in dual-phase sestamibi for parathyroid adenoma detection

被引:45
作者
Slater, A [1 ]
Gleeson, FV [1 ]
机构
[1] Churchill Hosp, Dept Radiol, Oxford OX3 7LJ, England
关键词
parathyroid adenoma; sestamibi; tomography; single photon; emission computed; SPECT;
D O I
10.1097/00003072-200501000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose of Report: To determine the usefulness of SPELT imaging over planar imaging for the detection of parathyroid adenomas using dual-phase Tc-99m sestamibi. Materials and Methods: The records of patients referred for dual-phase sestamibi scintigraphy for detection of parathyroid adenomas were reviewed retrospectively. The images were reviewed blindly and planar images were compared with SPELT. The imaging results were compared with the operative results to determine the sensitivity, accuracy of localization, and confidence of the reporting radiologist. Results: The records of 37 patients were reviewed. Sensitivity was 62% for planar imaging and 73% for SPELT. There was one false positive. The side of the adenoma was correctly identified in all other patients. Confidence of detection was higher for SPELT than for planar imaging. Conclusion: SPELT imaging increased the sensitivity and confidence of the detection of parathyroid adenomas. The results indicate that SPELT should be used for all preoperative parathyroid localization.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 10 条
  • [1] Bonjer HJ, 1997, EUR J SURG, V163, P27
  • [2] Chen CC, 1997, J NUCL MED, V38, P834
  • [3] Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localization of primary hyperparathyroidism
    Civelek, AC
    Ozalp, E
    Donovan, P
    Udelsman, R
    [J]. SURGERY, 2002, 131 (02) : 149 - 157
  • [4] Parathyroid glands:: Combination of 99mTc MIBI scintigraphy and US for demonstration of parathyroid glands and nodules
    De Feo, ML
    Colagrande, S
    Biagini, C
    Tonarelli, A
    Bisi, G
    Vaggelli, L
    Borrelli, D
    Cicchi, P
    Tonelli, F
    Amorosi, A
    Serio, M
    Brandi, ML
    [J]. RADIOLOGY, 2000, 214 (02) : 393 - 402
  • [5] The diagnostic utility of dual phase Tc-99m sestamibi parathyroid imaging
    Klieger, P
    O'Mara, R
    [J]. CLINICAL NUCLEAR MEDICINE, 1998, 23 (04) : 208 - 211
  • [6] Comparison among sonography, double-tracer subtraction scintigraphy, and double-phase scintigraphy in the detection of parathyroid lesions
    Mazzeo, S
    Caramella, D
    Lencioni, R
    Molea, N
    DeLiperi, A
    Marcocci, C
    Miccoli, P
    Iacconi, P
    Bossio, GB
    Viacava, P
    Lazzeri, E
    Bartolozzi, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) : 1465 - 1470
  • [7] Technetium 99m-MIBI-SPECT: A highly sensitive diagnostic tool for localization of parathyroid adenomas
    Moka, D
    Voth, E
    Dietlein, M
    Larena-Avellaneda, A
    Schicha, H
    [J]. SURGERY, 2000, 128 (01) : 29 - 35
  • [8] Comparison of double-phase Tc-99m-sestamibi with I-123-Tc-99m-sestamibi subtraction SPECT in hyperparathyroidism
    Neumann, DR
    Esselstyn, CB
    Go, RT
    Wong, CO
    Rice, TW
    Obuchowski, NA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) : 1671 - 1674
  • [9] Parathyroid imaging: preoperative localization
    O'Doherty, MJ
    Kettle, AG
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (02) : 125 - 131
  • [10] Trends in surgical techniques
    Thomas, SK
    Wishart, GC
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (02) : 115 - 119