A rapid method for the assessment of the vitality of microorganisms using flow cytometry

被引:4
|
作者
Bouix, Marielle [1 ]
Ghorbal, Sarrah [1 ]
Picque, Daniel [1 ]
Perret, Bruno [1 ]
Saulou-Berion, Claire [1 ]
机构
[1] Univ Paris Saclay, AgroParisTech, INRAe, UMR SayFood, Thiverval Grignon, France
关键词
bacteria; cellular state; flow cytometry; physiological state; vitality; yeast; SACCHAROMYCES-CEREVISIAE; PHYSIOLOGICAL STATES; OENOCOCCUS-OENI; VIABILITY; FERMENTATION; CARBOXYFLUORESCEIN; EXTRUSION; IMPACT; PH;
D O I
10.1002/cyto.a.24553
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cultivability, viability, and vitality make it possible to characterize the behavior of a cellular population. Vitality was assessed using the kinetic parameters of specific metabolisms depending on whether the strains were used, for example, for the acidification of lactic acid bacteria or for CO2 production in fermenting yeasts. However, these methods are time-consuming. We developed a cytometric descriptor based on the energy-dependent extrusion of carboxyfluorescein from cells, subsequent to carboxyfluorescein diacetate staining, and compared it to the measurements of metabolic activities of various bacteria and yeasts. For all of the microorganisms tested, the cytometric descriptor Delta FI15 was well correlated with the results of the metabolic measurements and, moreover, has the advantage of being easier and faster to use than metabolic methods. It can be very useful for evaluating the vitality of the starters before inoculation in industrial processes.
引用
收藏
页码:577 / 587
页数:11
相关论文
共 50 条
  • [1] RAPID ASSESSMENT OF BACTERIAL VIABILITY AND VITALITY BY RHODAMINE 123 AND FLOW-CYTOMETRY
    KAPRELYANTS, AS
    KELL, DB
    JOURNAL OF APPLIED BACTERIOLOGY, 1992, 72 (05): : 410 - 422
  • [2] A Novel Flow Cytometry Method for Rapid Assessment of Lentiviral Detection
    Wilkes, Fraser
    Crossland, Katherine L.
    Hunt, Joshua
    Howson, Sophie
    Hitchman, Elisabetta
    Warr, Andrew
    Abbott, Rachel J. M.
    Bath, Natalie
    MOLECULAR THERAPY, 2022, 30 (04) : 541 - 542
  • [3] A rapid method for immunotitration of influenza viruses using flow cytometry
    Lonsdale, R
    Pau, MG
    Oerlemans, M
    Ophorst, C
    Vooys, A
    Havenga, M
    Goudsmit, J
    UytdeHaag, F
    Marzio, G
    JOURNAL OF VIROLOGICAL METHODS, 2003, 110 (01) : 67 - 71
  • [4] A rapid method for infectivity titration of Andes hantavirus using flow cytometry
    Barriga, Gonzalo P.
    Martinez-Valdebenito, Constanza
    Galeno, Hector
    Ferres, Marcela
    Lozach, Pierre-Yves
    Tischler, Nicole D.
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 291 - 294
  • [5] Rapid assessment of hyperdiploidy in plasma cell disorders using a novel multi-parametric flow cytometry method
    Sidana, Surbhi
    Jevremovic, Dragan
    Ketterling, Rhett P.
    Tandon, Nidhi
    Dispenzieri, Angela
    Gertz, Morie A.
    Greipp, Patricia T.
    Baughn, Linda B.
    Buadi, Francis K.
    Lacy, Martha Q.
    Morice, William
    Hanson, Curtis
    Timm, Michael
    Dingli, David
    Haynnan, Suzanne R.
    Gonsalves, Wilson, I
    Kapoor, Prashant
    Kyle, Robert A.
    Leung, Nelson
    Go, Ronald S.
    Lust, John A.
    Rajkumar, S. Vincent
    Kumar, Shaji K.
    AMERICAN JOURNAL OF HEMATOLOGY, 2019, 94 (04) : 424 - 430
  • [6] RAPID ASSESSMENT OF BACTERIAL VIABILITY BY FLOW-CYTOMETRY
    DIAPER, JP
    TITHER, K
    EDWARDS, C
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1992, 38 (02) : 268 - 272
  • [7] A RAPID, OBJECTIVE METHOD FOR THE DETECTION OF LYMPHOCYTOTOXIC ANTIBODIES USING FLOW-CYTOMETRY
    TALBOT, D
    SHENTON, BK
    GIVAN, AL
    PROUD, G
    TAYLOR, RMR
    JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 99 (01) : 137 - 140
  • [8] An efficient and rapid transgenic pollen screening and detection method using flow cytometry
    Moon, Hong S.
    Eda, Shigetoshi
    Saxton, Arnold M.
    Ow, David W.
    Stewart, C. Neal, Jr.
    BIOTECHNOLOGY JOURNAL, 2011, 6 (01) : 118 - 123
  • [9] Rapid microbial analysis using flow cytometry
    Deere, D
    Vesey, G
    Veal, D
    AUSTRALASIAN BIOTECHNOLOGY, 1996, 6 (03) : 174 - 177
  • [10] Flow cytometry as a method for sperm quality assessment
    Siemieniuch, MJ
    Bielas, W
    Dubiel, A
    MEDYCYNA WETERYNARYJNA, 2004, 60 (12) : 1274 - 1277