Construction and verification of a physical chest phantom from suitable tissue equivalent materials for computed tomography examinations

被引:14
作者
Amini, Iman [1 ,2 ,3 ]
Akhlaghi, Parisa [1 ,2 ]
Sarbakhsh, Parvin [4 ]
机构
[1] Tabriz Univ Med Sci, Immunol Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Sch Med, Dept Med Phys, Golgasht Av, Tabriz, Iran
[3] Tabriz Univ Med Sci, Students Res Comm, Tabriz, Iran
[4] Tabriz Univ Med Sci, Sch Publ Hlth, Dept Biostat & Epidemiol, Tabriz, Iran
关键词
Physical chest phantom; Tissue equivalent materials; Hounsfield unit; Effective atomic number; Electron density; CT NUMBERS; RADIATION PROTECTION; CALIBRATION; RADIOTHERAPY; COEFFICIENTS; PARAMETERS; CONVERSION;
D O I
10.1016/j.radphyschem.2018.04.020
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Physical phantoms are used to optimize various imaging modalities (e.g. computed tomography) in terms of Xray image quality and absorbed dose. In this regard, this study tried to design and construct a suitable physical phantom with high accuracy and low price in diagnostic energy range. The phantom geometry was selected to be similar to a 5 cm thick cross-sectional slice of an adult human chest. To choose the appropriate tissue-equivalent materials, the physical properties (mass density, electron density and effective atomic number) of a wide range of available polymers were discussed and their accordance with those of human tissues were investigated. Phantom body was made of polymethylmethacrylate and 17 holes were considered in the phantom for placement of different tissue-equivalent materials. According to the physical properties, polypropylene, polyethylene, acrylonitrile butadiene styrene, polyurethane, polyamide and polyoxymethylene were selected and prepared for replacement of adipose, breasts, muscle, liver, cartilage and ribs, respectively. In addition, two different polyurethane foams were made of their raw materials for replacement of the lungs in inhalation and exhalation modes. Then, the prepared phantom was scanned by Siemens somatom sensation 64-slice scanner at tube voltage of 120 kVp and Hounsfield units of tissue-equivalent materials were measured. In addition, using theoretical relationships and goodness of fit test, their Hounsfield units were calculated. It was observed that, the calculated values were able to predict the measured values with the accuracy of 99%. Finally, the Hounsfield units of real human tissues were determined by the mathematical relationship obtained in the previous step; and in order to verify the outcomes, they were compared with other published reports. It was found that the Hounsfield units of real human tissues obtained using this physical phantom and Gammex RMI 465 phantom (scanned by Siemens somatom sensation 64) had the least differences. This demonstrated the high precision of the phantom and selected tissue substitutes, so it could be used in diagnostic energy range.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 33 条
  • [1] Development of a chest phantom for testing in Computed Tomography scans
    Aburjaile, W. N.
    Mourao, A. P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 275 - 277
  • [2] Evaluation of dose conversion coefficients for an eight-year-old Iranian male phantom undergoing computed tomography
    Akhlaghi, Parisa
    Hakimabad, Hashem Miri
    Motavalli, Laleh Rafat
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2015, 54 (04) : 465 - 474
  • [3] Determination of tissue equivalent materials of a physical 8-year-old phantom for use in computed tomography
    Akhlaghi, Parisa
    Hakimabad, Hashem Miri
    Motavalli, Laleh Rafat
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 112 : 169 - 176
  • [4] [Anonymous], THESIS
  • [5] [Anonymous], EFILM LIT US GUID
  • [6] [Anonymous], 2009, ANN ICR P
  • [7] [Anonymous], THESIS
  • [8] [Anonymous], HDB ANATOMICAL MODEL
  • [9] [Anonymous], P 2 INT C PEAC US AT
  • [10] A Comparison of physical and dosimetric properties of lung substitute materials
    Chang, Kwo-Ping
    Hung, Shang-Ho
    Chie, Yu-Huang
    Shiau, An-Cheng
    Huang, Ruey-Jing
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2013 - 2020