Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model

被引:206
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Brink, JA [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
aorta; CT; computed tomography (CT); contrast media; technology; liver;
D O I
10.1148/radiology.206.2.9457200
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography. MATERIALS AND METHODS: Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from the model at different injection rates (0.5-10.0 mL/sec). Time-enhancement curves were measured. The effect of contrast medium injection rate on the time and magnitude of peak enhancement was evaluated and validated empirically in pigs. RESULTS: Theoretic predictions and experimental results were in good agreement. Time to aortic peak enhancement was the sum of injection duration and bolus transfer time of contrast medium from the injection site to the aorta. Time to hepatic peak enhancement was the sum of Injection duration and time to equilibrium. The magnitude of peak enhancement increased with the injection rate, but the increase was different in the aorta and liver. CONCLUSION: Use of injection rates above 2 mL/sec did not substantially increase hepatic peak enhancement but helped increase the magnitude of arterial enhancement and temporal separation of arterial and venous phases of enhancement for dual-phase spiral CT.
引用
收藏
页码:455 / 464
页数:10
相关论文
共 20 条
  • [1] Bae KT, 1996, RADIOLOGY, V200, P288, DOI 10.1148/radiology.200.1.288-b
  • [2] BAE KT, 1995, RADIOLOGY, V197, P138
  • [3] BERLAND LL, 1995, RADIOLOGY, V195, P1
  • [4] HEPATIC CT ENHANCEMENT .2. ALTERATIONS IN CONTRAST MATERIAL VOLUME AND RATE OF INJECTION WITHIN THE SAME PATIENTS
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    [J]. RADIOLOGY, 1994, 193 (02) : 518 - 522
  • [5] BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION
    CLAUSSEN, CD
    BANZER, D
    PFRETZSCHNER, C
    KALENDER, WA
    SCHORNER, W
    [J]. RADIOLOGY, 1984, 153 (02) : 365 - 368
  • [6] Contrast agent pharmacokinetics revisited .1. Reformulation
    Dawson, P
    Blomley, MJK
    [J]. ACADEMIC RADIOLOGY, 1996, 3 : S261 - S263
  • [7] Definition of ''equilibrium point''
    Dawson, P
    Blomley, M
    [J]. RADIOLOGY, 1996, 200 (01) : 288 - 288
  • [8] HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION
    DEAN, PB
    VIOLANTE, MR
    MAHONEY, JA
    [J]. INVESTIGATIVE RADIOLOGY, 1980, 15 (02) : 158 - 161
  • [9] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [10] Effect of rate of contrast medium injection on hepatic enhancement at CT
    Garcia, PA
    Bonaldi, VM
    Bret, PM
    Liang, LJ
    Reinhold, C
    Atri, M
    [J]. RADIOLOGY, 1996, 199 (01) : 185 - 189