Visualizing mass transport in desorption electrospray ionization using time-of-flight secondary ion mass spectrometry: a look at the geometric configuration of the spray

被引:2
|
作者
Muramoto, Shin [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
EXPLOSIVES; MECHANISMS; MOLECULES; SURFACES; DESI; INSTRUMENTATION; CHEMISTRY; FORENSICS; SAMPLES; DRUGS;
D O I
10.1039/c4an01481b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to visualize the transport of analyte molecules desorbed onto a silicon wafer collection substrate by desorption electrospray ionization (DESI). The effect of spray incidence angle, tip height, and probe distance on the concentration and the spatial distribution of desorbed analyte molecules were investigated with the objective of identifying DESI operational parameters that provide more reproducible results by achieving steady ion transmission and minimized material loss. An incidence angle between 25 and 35 with respect to the plane of the surface provided the best compromise between maximizing ambient MS signal and achieving the best reliability. Glancing incidence angles provided higher ambient MS signals through a tighter dispersion of the secondary droplet plume, but run-to-run variability of as much as 40%. On the other hand, steeper incidence angles led to a widening of the lateral dispersion of the secondary droplets and decreased analyte desorption. For all incidence angles, shorter probe distances were preferred since the resulting tighter dispersion of the secondary droplets produced higher ion transmission and therefore higher ambient MS signals. Tip height was found to correlate with the spot size (footprint) of the spray on the surface; changing the tip height from (1 to 2 to 3) mm changed the diameter of the spray impact area from (1.3, 1.8, to 2.1) mm, respectively. For shorter probe to MS inlet distances, larger tip heights increased the ambient MS signal due to increased analyte desorption while maintaining a tighter dispersion of the secondary droplet plume. Equally important to optimizing instrument configuration was the understanding that the deposition of a sample onto the surface resulted in a coffee ring, where the diameter was larger than the spot size of the spray. Higher tip heights may be preferred for a more consistent analyte response since all or a large fraction of the analyte could be sampled to reduce variability in ambient MS response. The study showed that ToF-SIMS can be used as a unique tool for characterizing the transport of desorbed analyte molecules for DESI, and potentially offers insight into new interface designs for improved transmission of analyte into the mass spectrometer.
引用
收藏
页码:5868 / 5878
页数:11
相关论文
共 50 条
  • [1] Visualizing mass transport in desorption electrospray ionization using time-of-flight secondary ion mass spectrometry
    Muramoto, Shin
    Forbes, Thomas P.
    Staymates, Matthew E.
    Gillen, Greg
    ANALYST, 2014, 139 (11) : 2668 - 2673
  • [2] Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and Electrospray
    Janfelt, Christian
    Norgaard, Asger W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1670 - 1678
  • [3] Pharmaceutical cleaning validation using non-proximate large-area desorption electrospray ionization mass spectrometry
    Soparawalla, Santosh
    Salazar, Gary A.
    Perry, Richard H.
    Nicholas, Mark
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (01) : 131 - 137
  • [4] Effect of Electrospray Ionization Source Parameters on Pharmaceuticals Analysis Using Quadrupole Time-of-Flight Mass Spectrometry
    Masseren, Ummi Noor Salhah Binti
    Khor, Soo Wei
    Tay, Kheng Soo
    Bin Abas, Mhd Radzi
    CURRENT PHARMACEUTICAL ANALYSIS, 2016, 12 (04) : 300 - 305
  • [5] Pore confined time-of-flight secondary ion electrochemical mass spectrometry
    Wang, Jun-Gang
    Yu, Ru-Jia
    Hua, Xin
    Long, Yi-Tao
    CHEMICAL SOCIETY REVIEWS, 2023, 52 (08) : 2596 - 2616
  • [6] Trace detection of inorganic oxidants using desorption electrospray ionization (DESI) mass spectrometry
    Sokol, Ewa
    Jackson, Ayanna U.
    Cooks, R. Graham
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2011, 9 (05): : 790 - 797
  • [7] Method for enhancing peptide signal in time-of-flight secondary ion mass spectrometry
    Naito, Junpei
    Satoh, Shuya
    Otsuka, Yoichi
    Hashimoto, Hiroyuki
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 319 : 64 - 67
  • [8] Analysis of liposome model systems by time-of-flight secondary ion mass spectrometry
    Lovric, Jelena
    Keighron, Jacqueline D.
    Angerer, Tina B.
    Li, Xianchan
    Malmberg, Per
    Fletcher, John S.
    Ewing, Andrew G.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 74 - 78
  • [9] Direct Visualization of Chemical Transport in Solid-State Chemical Reactions by Time-of-Flight Secondary Ion Mass Spectrometry
    Pham, Sang T.
    Tieu, Anh Kiet
    Sun, Chao
    Wan, Shanhong
    Collins, Sean M.
    NANO LETTERS, 2024, 24 (12) : 3702 - 3709
  • [10] Development of Submillisecond Time-Resolved Mass Spectrometry Using Desorption Electrospray Ionization
    Miao, Zhixin
    Chen, Hao
    Liu, Pengyuan
    Liu, Yan
    ANALYTICAL CHEMISTRY, 2011, 83 (11) : 3994 - 3997