Evaluation of dental pulp temperature rise during photo-activated decontamination (PAD) of caries: an in vitro study

被引:15
作者
Nammour, Samir [1 ]
Zeinoun, T. [2 ]
Bogaerts, I. [1 ]
Lamy, M. [1 ]
Geerts, S. O. [1 ]
Saba, S. Bou [3 ]
Lamard, L. [4 ]
Peremans, A. [4 ]
Limme, M. [1 ]
机构
[1] Univ Liege, Dept Dent Sci, Fac Med, Liege, Belgium
[2] Lebanese Univ, Dept Oral & Maxillofacial Surg, Fac Dent Sci, Lebanese, Lebanon
[3] Catholic Univ Louvain, Sch Dent, B-3000 Louvain, Belgium
[4] Fac Univ Notre Dame Paix, LASMOS, B-5000 Namur, Belgium
关键词
PAD; Photo-activated decontamination; Laser; Dye; Photo-sensitizer; Caries; Pulp damage; TOLUIDINE-BLUE-O; LETHAL PHOTOSENSITIZATION; STREPTOCOCCUS-MUTANS; ANTIBACTERIAL ACTION; ORAL BACTERIA; ROOT CANALS; LIGHT; LASER; DISINFECTION; BIOFILMS;
D O I
10.1007/s10103-009-0683-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photo-activated decontamination (PAD) has been reported in caries treatment as an aid in dentine decontamination. The aim of this study is to verify the harmlessness for pulp vitality of photo-activated decontamination (PAD) in caries treatment. Twenty freshly extracted single-rooted teeth were used. Deep class I cavities with a a parts per thousand currency sign 0.5 mm dentine thickness between the floor of the cavity and the roof of cameral pulp were prepared. Following the manufacturer's instructions, cavities were filled with a photo-sensitizer (Phenothiazinechloride: 10 mg /ml), irradiated during 30 s with a 660-nm diode laser (output power: 40 mW in continuous wave; total delivered energy density: 4.87 J/cm(2)). Pulp temperature raises were recorded using a thermocouple (ALCr). Measurements were recorded every second during the irradiation and 150 s afterwards. Six records were repeated for each tooth. After 30 s of irradiation, the mean of temperature rise was 0.83A degrees C A +/- 0.22A degrees C. All records showed temperature increases lower than the 3A degrees C (safety level for pulp injury). Based on our in vitro study, we can conclude that the dental pulp temperature rise following the use of PAD technique for the decontamination of dentine can be considered as save procedure for pulp vitality.
引用
收藏
页码:651 / 654
页数:4
相关论文
共 22 条
[1]   Effect of photo-activated disinfection on endodontic pathogens ex vivo [J].
Bergmans, L. ;
Moisiadis, P. ;
Huybrechts, B. ;
Van Meerbeek, B. ;
Quirynen, M. ;
Lambrechts, P. .
INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (03) :227-239
[2]   Microbiological evaluation of photo-activated disinfection in endodontics (An in vivo study) [J].
Bonsor, SJ ;
Nichol, R ;
Reid, TMS ;
Pearson, GJ .
BRITISH DENTAL JOURNAL, 2006, 200 (06) :337-341
[3]  
Bonsor Stephen J, 2006, Dent Update, V33, P143
[4]   EFFECT OF DENTIN AND COLLAGEN ON THE LETHAL PHOTOSENSITIZATION OF STREPTOCOCCUS-MUTANS [J].
BURNS, T ;
WILSON, M ;
PEARSON, GJ .
CARIES RESEARCH, 1995, 29 (03) :192-197
[5]   KILLING OF CARIOGENIC BACTERIA BY LIGHT FROM A GALLIUM ALUMINUM ARSENIDE DIODE-LASER [J].
BURNS, T ;
WILSON, M ;
PEARSON, GJ .
JOURNAL OF DENTISTRY, 1994, 22 (05) :273-278
[6]   SENSITIZATION OF ORAL BACTERIA IN BIOFILMS TO KILLING BY LIGHT FROM A LOW-POWER LASER [J].
DOBSON, J ;
WILSON, M .
ARCHIVES OF ORAL BIOLOGY, 1992, 37 (11) :883-887
[7]   Lethal photosensitization for decontamination of implant surfaces in the treatment of peri-implantitis [J].
Dörtbudak, O ;
Haas, R ;
Bernhart, T ;
Mailath-Pokorny, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (02) :104-108
[8]  
HAAS R, 2000, LARYNGOSCOPE, V105, P867
[9]  
HENRIQUES FC, 1947, AM J PATHOL, V23, P531
[10]  
Lee Michael T, 2004, Aust Endod J, V30, P93