Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics

被引:6
作者
Novacek, Ladislav Viktor [1 ,2 ,3 ]
Nemcova, Marie [1 ]
Tyx, Katerina [1 ]
Lahodova, Kristyna [1 ]
Rejmont, Leos [2 ,3 ]
Rozsival, Pavel [1 ,4 ]
Studeny, Pavel [2 ,3 ]
机构
[1] Inst Aviat Med Prague, Dept Ophthalmol, Prague 16000, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Ophthalmol, Prague 12108, Czech Republic
[3] Mil Univ Hosp Prague, Prague 12108, Czech Republic
[4] Charles Univ Prague, Dept Ophthalmol, Sch Med Hradec Kralove, Hradec Kralove 50003, Czech Republic
关键词
presbyopia; multifocal intraocular lenses (MIOL); cataract; visual outcomes; visual function; contrast sensitivity; dysphotopsia; posterior capsule opacification; 677MY; 839M; ROTATIONAL STABILITY; CATARACT-EXTRACTION; IMPLANTATION; IOLS; DISSATISFACTION; OPACIFICATION; PERFORMANCE; EFFICACY;
D O I
10.3390/jcm10153268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)-the Liberty(R) 677MY or the AT LISA(R) tri 839M-in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome +/- 0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.
引用
收藏
页数:15
相关论文
共 49 条
[1]   World Medical Association Declaration of Helsinki Ethical Principles for Medical Research Involving Human Subjects [J].
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (20) :2191-2194
[2]  
[Anonymous], 2020, EUROTIMES
[3]  
Ashena Zahra, 2020, Vision (Basel), V4, DOI 10.3390/vision4030041
[4]   Vector Analysis, Rotational Stability, and Visual Outcome After Implantation of a New Aspheric Toric IOL [J].
Bachernegg, Alexander ;
Rueckl, Theresa ;
Strohmaier, Clemens ;
Jell, Gerlinde ;
Grabner, Guenther ;
Dexl, Alois K. .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (08) :513-520
[5]   Adverse clinical consequences of neodymium:YAG laser treatment of posterior capsule opacification [J].
Billotte, C ;
Berdeaux, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10) :2064-2071
[6]   Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses [J].
Buckhurst, Phillip J. ;
Naroo, Shehzad A. ;
Davies, Leon N. ;
Shah, Sunil ;
Drew, Tom ;
Wolffsohn, James S. .
BMJ OPEN OPHTHALMOLOGY, 2016, 1 (01)
[7]   Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification [J].
Buehl, Wolf ;
Menapace, Rupert ;
Findl, Oliver ;
Neumayer, Thomas ;
Bolz, Matthias ;
Prinz, Ana .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) :913-919
[8]   Effect of intraocular lens design on posterior capsule opacification [J].
Buehl, Wolf ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) :1976-1985
[9]   Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials [J].
Cao, Kai ;
Friedman, David S. ;
Jin, Shanshan ;
Yusufu, Mayinuer ;
Zhang, Jingshang ;
Wang, Jinda ;
Hou, Simeng ;
Zhu, Guyu ;
Wang, Bingsong ;
Xiong, Ying ;
Li, Jing ;
Li, Xiaoxia ;
He, Hailong ;
Chai, Lijing ;
Wan, Xiu Hua .
SURVEY OF OPHTHALMOLOGY, 2019, 64 (05) :647-658
[10]   Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: A meta-analysis [J].
Cheng, Jin-Wei ;
Wei, Rui-Li ;
Cai, Ji-Ping ;
Xi, Gui-Lin ;
Zhu, Huang ;
Li, You ;
Ma, Xiao-Ye .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :428-436