Two case studies on structural analysis of transmission towers under downburst

被引:15
|
作者
Yang, FengLi [1 ]
Zhang, HongJie [1 ]
机构
[1] China Elect Power Res Inst, Dept Engn Mech, Beijing 100055, Peoples R China
基金
中国国家自然科学基金;
关键词
downburst; wind speed profile; transmission tower; wind load; failure mode; TORNADO; MODEL;
D O I
10.12989/was.2016.22.6.685
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Downbursts are of great harm to transmission lines and many towers can even be destroyed. The downburst wind field model by Chen and Letchford was applied, and the wind loads of two typical transmission towers in inland areas and littoral areas were calculated separately. Spatial finite element models of the transmission towers were established by elastic beam and link elements. The wind loads as well as the dead loads of conductors and insulators were simplified and applied on the suspension points by concentrated form. Structural analysis on two typical transmission towers under normal wind and downburst was completed. The bearing characteristics and the failure modes of the transmission towers under downburst were determined. The failure state of tower members can be judged by the calculated stress ratios. It shows that stress states of the tower members were mainly controlled by 45 degree wind load. For the inland areas with low deign wind velocity, though the structural height is not in the highest wind velocity zone of downburst, the wind load under downburst is much higher than that under normal wind. The main members above the transverse separator of the legs will be firstly destroyed. For the littoral areas with high deign wind velocity, the wind load under downburst is lower than under normal wind. Transmission towers are not controlled by the wind loads from downbursts in design process.
引用
收藏
页码:685 / 701
页数:17
相关论文
共 50 条
  • [41] Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading
    Darwish, Mohamed M.
    El Damatty, Ashraf A.
    Hangan, Horia
    WIND AND STRUCTURES, 2010, 13 (04) : 327 - 346
  • [42] Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading
    Darwish M.M.
    Damatty A.A.E.I.
    Hangan H.
    Wind and Structures, An International Journal, 2010, 13 (04): : 327 - 346
  • [43] Study on the collapse failure of transmission tower-line system under downburst
    Bi W.-Z.
    Tian L.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 : 78 - 83
  • [44] Dynamic response of conductors during transmission tower failure under downburst loads
    Ahmed, Abdelrahman
    El Damatty, Ashraf
    ENGINEERING STRUCTURES, 2024, 305
  • [45] Vulnerability of transmission towers under intense wind loads
    Tapia-Hernandez, Edgar
    De-Leon-Escobedo, David
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2022, 18 (09) : 1235 - 1250
  • [46] Dynamic design of transmission towers under impact loads
    Abu-El-Yazied, TG
    ENGINEERING DESIGN CONFERENCE '98: DESIGN REUSE, 1998, : 529 - 536
  • [47] LIFTING OF TRANSMISSION TOWERS UNDER LIVE LINE CONDITIONS
    SKELTON, HE
    ORDE, CI
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (09): : 3018 - 3021
  • [48] Analytical Investigation of the Effects of Secondary Structural Members on the Structural Behaviors of Transmission Towers
    Kim, Pyounghwa
    Han, Whi Seok
    Kim, Jeong Hun
    Lee, Jeonghwa
    Kang, Young Jong
    Kim, Seungjun
    BUILDINGS, 2023, 13 (01)
  • [49] STRUCTURAL MEMBRANES IN MEXICO: TWO CASE STUDIES
    Oliva Salinas, Juan Gerardo
    Valdez Olmedo, Eric
    TEXTILE COMPOSITES AND INFLATABLE STRUCTURES VI, 2013, : 268 - 277
  • [50] Experimental validation of a simplified structural design for lattice transmission towers
    Kim, Pyounghwa
    Han, Whi Seok
    Kim, Heesoo
    Kim, Jeong Hun
    Kang, Young Jong
    Kim, Seungjun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226