Evaluation of polarity switching for untargeted lipidomics using liquid chromatography coupled to high resolution mass spectrometry

被引:9
|
作者
Carlsson, Henrik [1 ]
Vaivade, Aina [1 ]
Khoonsari, Payam Emami [1 ,2 ]
Burman, Joachim [1 ,2 ]
Kultima, Kim [1 ]
机构
[1] Uppsala Univ, Dept Med Sci, Clin Chem, S-75185 Uppsala, Sweden
[2] Uppsala Univ, Dept Neurosci, S-75185 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Lipidomics; Untargeted mass spectrometry; Polarity switching; Positive/negative switching; EXTRACTION;
D O I
10.1016/j.jchromb.2022.123200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Untargeted lipidomics using liquid chromatography high-resolution mass spectrometry (LC-HRMS) was performed using polarity switching, and in positive and negative polarity separately on the same set of serum samples, and the performances of the methods were evaluated. Polarity switching causes an increase in the cycle time of the HRMS measurements (1.18 s/cycle vs 0.27 s/ cycle), resulting in fewer data points across chromatographic peaks. The coefficient of variation (CV) was on average lower for the added isotopically labelled standards in pooled samples (QC) and patient samples using separate polarities (QC = 5.6%, samples = 12.5%) compared to polarity switching (QC = 8.5%, samples = 13.4%), but the difference was not statistically significant. For the endogenous features measured in the QCs polarity switching resulted in on average significantly higher CVs (3.80 (p = 4.25e-30) and 3.3 percentage points (p = 6.84e-40), for positive and negative modes, respectively) however still acceptable for an untargeted method (mean CVs of 17.9% and 12.2% in positive and negative modes respectively). A slightly larger number of endogenous features were detected using the separate polarities, but the large majority of features (> 95%) were detected with both methodologies. The overlap of features detected in both positive and negative polarities was low (4.1%) demonstrating the importance of using both polarities for untargeted lipidomics. When investigating the effects of a treatment on multiple sclerosis patients it was found that both methodologies gave highly similar biological results, further confirming the applicability of polarity switching.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Lipidomics profiling of zebrafish liver through untargeted liquid chromatography-high resolution mass spectrometry
    da Silva, Katyeny Manuela
    Iturrospe, Elias
    van den Boom, Rik
    van de Lavoir, Maria
    Robeyns, Rani
    Vergauwen, Lucia
    Knapen, Dries
    Cuykx, Matthias
    Covaci, Adrian
    van Nuijs, Alexander L. N.
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (15) : 2935 - 2945
  • [2] Validating Quantitative Untargeted Lipidomics Across Nine Liquid Chromatography-High-Resolution Mass Spectrometry Platforms
    Cajka, Tomas
    Smilowitz, Jennifer T.
    Fiehn, Oliver
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12360 - 12368
  • [3] Lipidomics of common octopus' (Octopus vulgaris) arm muscle using untargeted high-resolution liquid chromatography-mass spectrometry
    Gaspar, Luis
    Ricardo, Fernando
    Melo, Tania
    Domingues, Pedro
    Domingues, M. Rosario
    Calado, Ricardo
    Rey, Felisa
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 115
  • [4] Lipidomics Analysis of Different Marine Fish Oils Using Untargeted Liquid Chromatography–Orbitrap High-Resolution Mass Spectrometry and Chemometrics
    Anjar Windarsih
    Hendy Dwi Irnawati
    Lucky Prabowo Miftachul Suratno
    Indrawati Dian Warmiko
    Abdul Alam
    Anastasia Wheni Utami
    Chromatographia, 2024, 87 : 203 - 214
  • [5] Single Cell Untargeted Lipidomics Using Liquid Chromatography Ion Mobility-Mass Spectrometry
    Kim, Jinyong
    Mun, Dong-Gi
    Ding, Husheng
    Forsberg, Erica Marie
    Meyer, Sven W.
    Barsch, Aiko
    Pandey, Akhilesh
    Byeon, Seul Kee
    JOURNAL OF PROTEOME RESEARCH, 2025, 24 (04) : 1579 - 1585
  • [6] Lipidomics Analysis of Different Marine Fish Oils Using Untargeted Liquid Chromatography-Orbitrap High-Resolution Mass Spectrometry and Chemometrics
    Windarsih, Anjar
    Irnawati
    Suratno
    Warmiko, Hendy Dwi
    Alam, Lucky Prabowo Miftachul
    Utami, Indrawati Dian
    Rohman, Abdul
    Indrianingsih, Anastasia Wheni
    CHROMATOGRAPHIA, 2024, 87 (04) : 203 - 214
  • [7] Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry
    Capriotti, Anna Laura
    Cavaliere, Chiara
    La Barbera, Giorgia
    Montone, Carmela Maria
    Piovesana, Susy
    Chiozzi, Riccardo Zenezini
    Lagana, Aldo
    TALANTA, 2018, 179 : 792 - 802
  • [8] Untargeted metabolomics approaches for the characterization of cereals and their derived products by means of liquid chromatography coupled to high resolution mass spectrometry
    Bozza, Desiree
    Barboni, Davide
    Spadafora, Natasha Damiana
    Felletti, Simona
    De Luca, Chiara
    Nosengo, Chiara
    Compagnin, Greta
    Cavazzini, Alberto
    Catani, Martina
    JOURNAL OF CHROMATOGRAPHY OPEN, 2024, 6
  • [9] Evaluation of mycotoxins and their metabolites in human breast milk using liquid chromatography coupled to high resolution mass spectrometry
    Rubert, Josep
    Leon, Nuria
    Saez, Carmen
    Martins, Claudia P. B.
    Godula, Michal
    Yusa, Vicent
    Manes, Jordi
    Soriano, Jose Miguel
    Soler, Carla
    ANALYTICA CHIMICA ACTA, 2014, 820 : 39 - 46
  • [10] Optimization of a liquid chromatography-ion mobility-high resolution mass spectrometry platform for untargeted lipidomics and application to HepaRG cell extracts
    da Silva, Katyeny Manuela
    Iturrospe, Elias
    Heyrman, Joris
    Koelmel, Jeremy P.
    Cuykx, Matthias
    Vanhaecke, Tamara
    Covaci, Adrian
    van Nuijs, Alexander L. N.
    TALANTA, 2021, 235