Switching transients in overhead transmission line 220 kV

被引:0
|
作者
Vasileva, Margreta [1 ]
Stanchev, Danail [2 ]
机构
[1] Med Univ Varna, Dept Med Equipment Elect & Informat Technol Healt, Varna, Bulgaria
[2] Tech Univ Varna, Power Engn Dept, Shumen, Bulgaria
关键词
switching overvoltages; energization; overhead line; surge arrester; atp-emtp software;
D O I
10.1109/eeae49144.2020.9279055
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Power system is exposed to overvoltages due to different reasons. Switching overvoltages are one of common causes of outages and damages in the system. Switching overvoltages are caused by circuit breaker operations. These operations are classified as closing and reclosing. Overhead line energization and de-energization causes switching surges. These surges under certain conditions can be dangerous for the facilities in the power substations. Therefore the knowledge of overvoltage levels and the factors affecting them is important for power system reliability. In this paper switching overvoltages due to closing and re-closing operations of overhead power line 220 kV are investigated through model study. ATP-EMTP software is used for power system modeling. Case studies without using surge arresters and with surge arresters are reviewed in the paper. Overvoltages in different location on overhead line are shown.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Switching Overvoltage Research of ±500 kV Flexible HVDC Grid With Overhead Line
    Sun X.
    Chen S.
    Huang T.
    Lie X.
    Jiang W.
    Wu Y.
    Chen Y.
    Sun, Xu (sunxu_bj@163.com), 1600, Power System Technology Press (41): : 1498 - 1502
  • [23] "Virtual" Power Line Method to Correct the Calculation of Current Ground Faults in the Parallel Overhead Transmission Lines 110-220 kV
    Ukraintsev, A., V
    Nagay, I., V
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [24] Study of the impact of 220 kV SISFCL on the distance protection for transmission line
    Luo, Yinghong
    Shi, Tongtong
    Huang, Linke
    ARCHIVES OF ELECTRICAL ENGINEERING, 2018, 67 (01) : 151 - 163
  • [25] Failure Analysis on Strain Clamp on 220kV Transmission Line
    Xu, XueXia
    Feng, YanTing
    Ke, Hao
    Niu, XiaoGuang
    Ouyang, Jie
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1405 - 1409
  • [26] 220 kV transmission in California
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1922, 66 : 733 - 733
  • [27] Transmission Line TRANSIENTS
    Darney, Ian
    ELECTRONICS WORLD, 2011, 117 (1897): : 26 - 29
  • [28] TRANSMISSION LINE TRANSIENTS
    Darney, Ian
    ELECTRONICS WORLD, 2009, 115 (1878): : 42 - 43
  • [29] Transmission Line Arresters Application for Control of Switching Overvoltages on 500-kV Transmission Line
    Bunov, P.
    Klingbeil, L.
    Schubert, M.
    Gossler, B.
    Biswas, D.
    Hunt, James
    Thallam, R.
    Keri, A. J. F.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [30] Contaminated Insulators on 220 kV Overhead Lines.
    Kaiser, F.
    1600, (37):