Three-Dimensional Planning and Use of Individualized Osteotomy-Guiding Templates for Surgical Correction of Kyphoscoliosis: A Technical Case Report

被引:23
作者
Pijpker, Peter A. J. [1 ]
Kuijlen, Jos M. A. [1 ]
Kraeima, Joep [2 ]
Faber, Chris [3 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Neurosurg, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Orthoped Surg, Groningen, Netherlands
关键词
3D planning; 3D printing; 3D surgery; Kyphosis; Scoliosis; Spinal deformity; Templates; VERTEBRAL COLUMN RESECTION; SPINE; RECONSTRUCTION; PLACEMENT; FIBULA;
D O I
10.1016/j.wneu.2018.07.219
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: We have described the use of 3-dimensional (3D) virtual planning and 3D printed patient-specific osteotomy templates in the surgical correction of a complex spinal deformity. Pedicle subtraction osteotomies (PSOs) for the correction of severe spinal deformities are technically demanding procedures with a risk of major complications. In particular, operations of the severely deformed spine call for new, more precise, methods of surgical planning. The new 3D technology could result in new possibilities for the surgical planning of spinal deformities. METHODS: We present the case of severe congenital kyphoscoliosis in a young girl with skeletal dysplasia. A closing wedge-extended PSO was 3D virtual planned using medical computer design software. After the optimal 3D-wedge procedure was planned, individualized osteotomy-guiding templates were designed for translation of the planned PSO to the surgical procedure. During surgery, the PSO was performed using the osteotomy templates. Successful correction of the kyphoscoliosis was realized. RESULTS: The kyphosis was successfully reduced using a wedge-shaped extended PSO using preoperative 3D virtual planning, assisted by 3D-printed individualized osteotomy-guiding templates. CONCLUSIONS: In addition to direct translation of the planned PSO for surgery, the 3D planning also facilitated a detailed preoperative evaluation, greater insight into the case-specific anatomy, and accurate planning of the required correction.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 14 条
  • [1] Decision making regarding Smith-Petersen vs. pedicle subtraction osteotomy vs. vertebral column resection for spinal deformity
    Bridwell, Keith H.
    [J]. SPINE, 2006, 31 (19) : S171 - S178
  • [2] Computer-assisted total knee arthroplasty using patient-specific templating
    Hafez, M. A.
    Chelule, K. L.
    Seedhom, B. B.
    Sherman, K. P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) : 184 - 192
  • [3] Use of Computer-Aided Design and Computer-Aided Manufacturing to Produce Orthognathically Ideal Surgical Outcomes: A Paradigm Shift in Head and Neck Reconstruction
    Hirsch, David L.
    Garfein, Evan S.
    Christensen, Andrew M.
    Weimer, Katherine A.
    Saddeh, Pierre B.
    Levine, Jamie P.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (10) : 2115 - 2122
  • [4] A review of rapid prototyped surgical guides for patient-specific total knee replacement
    Krishnan, S. P.
    Dawood, A.
    Richards, R.
    Henckel, J.
    Hart, A. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 1457 - 1461
  • [5] A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine
    Merc, Matjaz
    Drstvensek, Igor
    Vogrin, Matjaz
    Brajlih, Tomaz
    Recnik, Gregor
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 893 - 899
  • [6] Aplication of the stereolithography technique in complex spine surgery
    Paiva, Wellingson Silva
    Amorim, Robson
    Franca Bezerra, Douglas Alexandre
    Masini, Marcos
    [J]. ARQUIVOS DE NEURO-PSIQUIATRIA, 2007, 65 (2B) : 443 - 445
  • [7] Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides: A Human Cadaver Study
    Pijpker, Peter A. J.
    Kraeima, Joep
    Witjes, Max J. H.
    Oterdoom, D. L. Marinus
    Coppes, Maarten H.
    Groen, Rob J. M.
    Kuijlen, Jos M. A.
    [J]. OPERATIVE NEUROSURGERY, 2019, 16 (01) : 94 - 102
  • [8] Accuracy of fibula reconstruction using patient-specific CAD/CAM reconstruction plates and dental implants: A new modality for functional reconstruction of mandibular defects
    Schepers, Rutger H.
    Raghoebar, Gerry M.
    Vissink, Arjan
    Stenekes, Martin W.
    Kraeima, Joep
    Roodenburg, Jan L.
    Reintsema, Harry
    Witjes, Max J.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (05) : 649 - 657
  • [9] Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction
    Schepers, Rutger H.
    Raghoebar, Gerry M.
    Vissink, Arjan
    Lahoda, Lars U.
    Van der Meer, W. Joerd
    Roodenburg, Jan L.
    Reintsema, Harry
    Witjes, Max J.
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (04): : E109 - E114
  • [10] Schwab F., 2013, Neurosurgery, V76, pS33, DOI DOI 10.1227/NEU.0000000000000182