The effect on intracuff pressure of various nitrous oxide concentrations used for inflating an endotracheal tube cuff

被引:28
作者
Karasawa, F [1 ]
Ohshima, T [1 ]
Takamatsu, I [1 ]
Ehata, T [1 ]
Fukuda, I [1 ]
Uchihashi, Y [1 ]
Satoh, T [1 ]
机构
[1] Natl Def Med Coll, Dept Anesthesiol, Tokorozawa, Saitama 3598513, Japan
关键词
D O I
10.1213/00000539-200009000-00040
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We sought to determine the optimal concentration of nitrous oxide (N2O) for inflating endotracheal tube cuffs, to avoid overinflation and air leaks. Female patients undergoing endotracheal intubation (inner diameter 7.5 mm) during anesthesia with 67% N2O were randomly assigned to five groups of 25 subjects each, in which cuffs were inflated with 0% (Air), 30% (N30), 40% (N40), 50% (N50), or 67% (N67) N2O. The cuff pressure and the N2O concentration in the cuff were measured. In an additional 15 patients (N40-a group), pilot balloons were replaced with metal tubes, and the mouths and noses of the patients were wrapped with tape, to minimize N2O efflux into the air. Postoperative sore throats were evaluated in double-blinded interviews. Cuff pressures increased significantly in the Air and N30 groups but decreased in the N67 group. Cuff pressures were <22 mm Hg in the N40 and N50 groups, but the N50 group had air leaks. The N2O concentration in the cuff in the N40 group was significantly smaller than that in the N40-a group, suggesting N2O rediffusion. The incidence of sore throats (40% in the Air group) was reduced significantly in the N40 and N50 groups. Therefore, 40% N2O is optimal for filling the cuff during anesthesia with 67% N2O.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 23 条
[1]  
BRANDT L, 1983, ANAESTHESIST, V32, P459
[2]   HOW TO USE RIDIT ANALYSIS [J].
BROSS, IDJ .
BIOMETRICS, 1958, 14 (01) :18-38
[3]  
CAPAN LM, 1983, ANESTHESIOLOGY, V59, P202
[4]  
CARROLL R G, 1974, International Anesthesiology Clinics, V12, P111, DOI 10.1097/00004311-197412030-00008
[5]  
Fill D M, 1994, AANA J, V62, P77
[6]   A NEW ENDOTRACHEAL-TUBE WITH A CUFF IMPERVIOUS TO NITROUS-OXIDE - CONSTANCY OF CUFF PRESSURE AND VOLUME [J].
FUJIWARA, M ;
MIZOGUCHI, H ;
KAWAMURA, J ;
HAYASHI, I ;
TAKAKUWA, R ;
MORINAGA, N ;
YANAGAWA, T ;
CHIBA, T ;
ODASHIRO, M .
ANESTHESIA AND ANALGESIA, 1995, 81 (05) :1084-1086
[7]  
Hakim M., 1993, ACTA ANAESTH SCAND, V37, P250
[8]  
HANNALLAH MS, 1993, ANESTH ANALG, V77, P1222
[9]  
KIM JM, 1980, ANESTH ANALG, V59, P291
[10]   THE INFLUENCE OF ENDOTRACHEAL-TUBE CUFF DESIGN AND CUFF LUBRICATION ON POSTOPERATIVE SORE THROAT [J].
LOESER, EA ;
KAMINSKY, A ;
DIAZ, A ;
STANLEY, TH ;
PACE, NL .
ANESTHESIOLOGY, 1983, 58 (04) :376-379