Arthroscopic Fixation Technique for Comminuted, Displaced Greater Tuberosity Fracture

被引:48
作者
Ji, Jong-Hun [1 ]
Shafi, Mohamed [1 ]
Song, In-Soo [2 ]
Kim, Young-Yul [1 ]
McFarland, Edward G. [3 ]
Moon, Chang-Yun [1 ]
机构
[1] Catholic Univ Korea, Daejon St Marys Hosp, Dept Orthoped Surg, Coll Med, Taejon 302803, South Korea
[2] Sun Hosp, Taejon, South Korea
[3] Johns Hopkins Univ, Baltimore, MD USA
关键词
SUTURE-ANCHOR FIXATION; ROTATOR CUFF REPAIR; SINGLE-ROW; INTERNAL-FIXATION; PROXIMAL HUMERUS; REDUCTION; EPIDEMIOLOGY; FOOTPRINT; PRESSURE; SHOULDER;
D O I
10.1016/j.arthro.2009.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this retrospective study was to evaluate the early results of arthroscopic treatment in patients with comminuted, displaced greater tuberosity (GT) fractures using the arthroscopic double-row suture anchor fixation (ADSF) technique. Methods: Between August 2004 and December 2007, we used the ADSF technique in 16 cases of isolated comminuted, displaced GT fractures. The early clinical results were evaluated in these patients at a mean of 24 months (range, 16 to 51 months) after surgery. There were 11 male and 5 female patients with a mean age of 56.5 years (range, 27 to 82 years). These 16 cases had at least 5 mm of displacement of the fracture fragments in any plane. For measurement of clinical outcomes, we assessed range of motion and evaluated the visual analog scale score; the University of California, Los Angeles (UCLA) rating scale; and the shoulder index of the American Shoulder and Elbow Surgeons. Results: At final follow-up, the visual analog scale score improved from 9.4 (range, 8 to 10 points) to 1.2 (range, 0 to 4 points), the mean UCLA score improved to 31 points (range, 21 to 35 points) postoperatively, and the American Shoulder and Elbow Surgeons score improved to 88.1 points (range, 81.5 to 100 points). According to the UCLA score, there were 3 excellent results, 11 good results, and 2 poor results. Mean forward flexion was 148.7 degrees (range, 120 degrees to 170 degrees), mean abduction was 145 degrees (range, 120 degrees to 170 degrees), mean external rotation in the neutral position was 24 degrees (range, 10 degrees to 40 degrees), and internal rotation improved to the first lumbar vertebral level (from L3 to T7) at last follow-up. Conclusions: The early results of the ADSF technique used for displaced, comminuted GT fractures are encouraging, and arthroscopists should attempt to expand the indications for arthroscopic treatment of these fractures. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:600 / 609
页数:10
相关论文
共 50 条
  • [31] Surgical Treatment of Displaced Greater Tuberosity Fractures of the Humerus
    Rouleau, Dominique M.
    Mutch, Jennifer
    Laflamme, Georges-Yves
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (01) : 46 - 56
  • [32] Different suture anchor fixation techniques affect contact properties in humeral greater tuberosity fracture: a biomechanical study
    Lin, Cheng-Li
    Yeh, Ming-Long
    Su, Fong-Chin
    Wang, Yu-Chih
    Chiang, Chen-Hao
    Hong, Chih-Kai
    Su, Wei-Ren
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [33] Arthroscopic Management of Glenoid and Greater Tuberosity Bipolar Fractures
    Zhang, Qing
    Xiang, Ming
    Li, Yi-ping
    Yang, Jin-song
    ORTHOPAEDIC SURGERY, 2020, 12 (05) : 1405 - 1412
  • [34] Displaced isolated greater tuberosity fractures of elder adults treated with plate osteosynthesis
    Cheng, Ming Fai
    Hung, Shih-Hsin
    Su, Yu-Pin
    Chiang, Chao-Ching
    Chang, Ming-Chau
    Chiu, Fang-Yao
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (04) : 318 - 321
  • [35] Augmented cerclage wire improves the fixation strength of a two-screw construct for humerus split type greater tuberosity fracture: a biomechanical study
    Chang, Chao-Jui
    Su, Wei-Ren
    Hsu, Kai-Lan
    Hong, Chih-Kai
    Kuan, Fa-Chuan
    Chang, Chih-Hsun
    Lin, Cheng-Li
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [36] ARTHROSCOPIC REDUCTION AND FIXATION OF A COMPLETELY DISPLACED FRACTURE OF THE INTERCONDYLAR EMINENCE OF THE TIBIA
    KOBAYASHI, S
    TERAYAMA, K
    ARTHROSCOPY, 1994, 10 (02): : 231 - 235
  • [37] Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study
    Seppel, Gernot
    Saier, Tim
    Martetschlaeger, Frank
    Plath, Johannes E.
    Guevara-Alvarez, Alberto
    Henschel, Julia
    Winkler, Martin
    Augat, Peter
    Imhoff, Andreas B.
    Buchmann, Stefan
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [38] Radiological and biomechanical assessment of displaced greater tuberosity fractures
    Richard W. Nyffeler
    Angela Seidel
    Stefan Werlen
    Mathias Bergmann
    International Orthopaedics, 2019, 43 : 1479 - 1486
  • [39] Osteosynthesis of displaced fractures of the greater tuberosity with the Bamberg plate
    Popp, D.
    Schoeffl, V.
    Strecker, W.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (05): : 392 - 401
  • [40] Arthroscopic Findings of Coexisting Lesions With Greater Tuberosity Fractures
    Maman, Eran
    Dolkart, Oleg
    Chechik, Ofir
    Amar, Eyal
    Rak, Ofer
    Rath, Ehud
    Mozes, Gavriel
    ORTHOPEDICS, 2014, 37 (03) : E272 - E277