Arthroscopic Fixation Technique for Comminuted, Displaced Greater Tuberosity Fracture

被引:48
作者
Ji, Jong-Hun [1 ]
Shafi, Mohamed [1 ]
Song, In-Soo [2 ]
Kim, Young-Yul [1 ]
McFarland, Edward G. [3 ]
Moon, Chang-Yun [1 ]
机构
[1] Catholic Univ Korea, Daejon St Marys Hosp, Dept Orthoped Surg, Coll Med, Taejon 302803, South Korea
[2] Sun Hosp, Taejon, South Korea
[3] Johns Hopkins Univ, Baltimore, MD USA
关键词
SUTURE-ANCHOR FIXATION; ROTATOR CUFF REPAIR; SINGLE-ROW; INTERNAL-FIXATION; PROXIMAL HUMERUS; REDUCTION; EPIDEMIOLOGY; FOOTPRINT; PRESSURE; SHOULDER;
D O I
10.1016/j.arthro.2009.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this retrospective study was to evaluate the early results of arthroscopic treatment in patients with comminuted, displaced greater tuberosity (GT) fractures using the arthroscopic double-row suture anchor fixation (ADSF) technique. Methods: Between August 2004 and December 2007, we used the ADSF technique in 16 cases of isolated comminuted, displaced GT fractures. The early clinical results were evaluated in these patients at a mean of 24 months (range, 16 to 51 months) after surgery. There were 11 male and 5 female patients with a mean age of 56.5 years (range, 27 to 82 years). These 16 cases had at least 5 mm of displacement of the fracture fragments in any plane. For measurement of clinical outcomes, we assessed range of motion and evaluated the visual analog scale score; the University of California, Los Angeles (UCLA) rating scale; and the shoulder index of the American Shoulder and Elbow Surgeons. Results: At final follow-up, the visual analog scale score improved from 9.4 (range, 8 to 10 points) to 1.2 (range, 0 to 4 points), the mean UCLA score improved to 31 points (range, 21 to 35 points) postoperatively, and the American Shoulder and Elbow Surgeons score improved to 88.1 points (range, 81.5 to 100 points). According to the UCLA score, there were 3 excellent results, 11 good results, and 2 poor results. Mean forward flexion was 148.7 degrees (range, 120 degrees to 170 degrees), mean abduction was 145 degrees (range, 120 degrees to 170 degrees), mean external rotation in the neutral position was 24 degrees (range, 10 degrees to 40 degrees), and internal rotation improved to the first lumbar vertebral level (from L3 to T7) at last follow-up. Conclusions: The early results of the ADSF technique used for displaced, comminuted GT fractures are encouraging, and arthroscopists should attempt to expand the indications for arthroscopic treatment of these fractures. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:600 / 609
页数:10
相关论文
共 50 条
  • [21] Arthroscopic fixation for a malunited greater tuberosity fracture using the suture-bridge technique: technical report and literature review
    Ji, Jong-Hun
    Moon, Chang-Yun
    Kim, Young-Yul
    Shafi, Mohamed
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (12) : 1473 - 1476
  • [22] Comparison between arthroscopic suture anchor fixation and open plate fixation in the greater tuberosity fracture of the proximal humerus
    Kim, Young-Jun
    Ji, Jong-Hun
    Park, Sang-Eun
    Parikh, Darshil
    Lee, Woo-Jin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01) : 621 - 631
  • [23] A Mid-Scapular Portal for Arthroscopic-Assisted Fixation of Severe Retraction Greater Tuberosity Avulsion Fracture
    Jaruwanneechai, Khananut
    Boonrod, Artit
    ARTHROSCOPY TECHNIQUES, 2022, 11 (11): : E1897 - E1902
  • [24] Plate Fixation versus Arthroscopic-Assisted Plate Fixation for Isolated Medium-Sized Fractures of the Greater Tuberosity: A Retrospective Study
    Sun, Qi
    Ge, Wei
    Li, Gen
    Wu, Jie Zhou
    Lu, Guanghua
    Li, Runmin
    Zhao, Zhenyu
    Zhu, Yaru
    Xu, Youzhi
    Lei, Wang
    Cai, Ming
    ORTHOPAEDIC SURGERY, 2020, 12 (05) : 1456 - 1463
  • [25] Arthroscopic management of occult greater tuberosity fracture of the shoulder
    Park S.-E.
    Ji J.-H.
    Shafi M.
    Jung J.J.
    Gil H.-J.
    Lee H.-H.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (4) : 475 - 482
  • [26] Comparison between arthroscopic suture anchor fixation and open plate fixation in the greater tuberosity fracture of the proximal humerus
    Young-Jun Kim
    Jong-Hun Ji
    Sang-Eun Park
    Darshil Parikh
    Woo-Jin Lee
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 (1) : 621 - 631
  • [27] Outcomes of surgical fixation of greater tuberosity fractures: A systematic review
    Huntley, Samuel R.
    Lehtonen, Eva J.
    Robin, Joseph Xavier
    Arguello, Alexandra M.
    Rouleau, Dominique M.
    Brabston, Eugene W.
    Ponce, Brent A.
    Momaya, Amit M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (06) : 1119 - 1126
  • [28] Fractures of the greater tuberosity of the humerus Arthroscopic treatment strategies
    Akguen, Doruk
    Pauly, Stephan
    Stoeckle, Ulrich
    Thiele, Kathi
    ARTHROSKOPIE, 2023, 36 (02) : 73 - 79
  • [29] Clinical outcomes of minimally invasive open reduction and internal fixation by screw and washer for displaced greater tuberosity fracture of the humerus
    Yoon, Tae-Hwan
    Choi, Chong-Hyuk
    Choi, Yun-Rak
    Oh, Jong-Taek
    Chun, Yong-Min
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : E173 - E177
  • [30] Radiological and biomechanical assessment of displaced greater tuberosity fractures
    Nyffeler, Richard W.
    Seidel, Angela
    Werlen, Stefan
    Bergmann, Mathias
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1479 - 1486